J L Pépin1, R Tamisier1, J P Baguet2, B Lepaulle3, F Arbib3, N Arnol1, J F Timsit4, P Lévy1. 1. University of Grenoble Alpes, HP2; Inserm, U1042, Grenoble, France CHU de Grenoble, Laboratoire EFCR, Pôle THORAX et VAISSEAUX, Grenoble, France. 2. Groupe Hospitalier Mutualiste de Grenoble, Clinique de Cardiologie, Grenoble, France. 3. Cabinet de Pneumologie privé, Echirolles, France. 4. IAME UMR 1137 Inserm Université Paris Diderot, F-75018, Paris, France.
Abstract
BACKGROUND: Millions of individuals with obstructive sleep apnoea (OSA) are treated by CPAP aimed at reducing blood pressure (BP) and thus cardiovascular risk. However, evidence is scarce concerning the impact of different CPAP modalities on BP evolution. METHODS: This double-blind, randomised clinical trial of parallel groups of patients with OSA indicated forCPAP treatment compared the efficacy of fixed-pressure CPAP (FP-CPAP) with auto-adjusting CPAP (AutoCPAP) in reducing BP. The primary endpoint was the change in office systolic BP after 4 months. Secondary endpoints included 24 h BP measurements. RESULTS:Patients (322) were randomised to FP-CPAP (n=161) or AutoCPAP (n=161). The mean apnoea+hypopnoea index (AHI) was 43/h (SD, 21); mean age was 57 (SD, 11), with 70% of males; mean body mass index was 31.3 kg/m(2) (SD, 6.6) and median device use was 5.1 h/night. In the intention-to-treat analysis, office systolic blood pressure decreased by 2.2 mm Hg (95% CI -5.8 to 1.4) and 0.4 mm Hg (-4.3 to 3.4) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.3 mm Hg (95% CI -4.1 to 1.5); p=0.37, adjusted for baseline BP values). 24 h diastolic BP (DBP) decreased by 1.7 mm Hg (95% CI -3.9 to 0.5) and 0.5 mm Hg (95% CI -2.3 to 1.3) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.4 mm Hg (95% CI -2.7 to -0.01); p=0.048, adjusted for baseline BP values). CONCLUSIONS: The result was negative regarding the primary outcome of office BP, while FP-CPAP was more effective in reducing 24 h DBP (a secondary outcome). TRIAL REGISTRATION NUMBER: NCT01090297. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
RCT Entities:
BACKGROUND: Millions of individuals with obstructive sleep apnoea (OSA) are treated by CPAP aimed at reducing blood pressure (BP) and thus cardiovascular risk. However, evidence is scarce concerning the impact of different CPAP modalities on BP evolution. METHODS: This double-blind, randomised clinical trial of parallel groups of patients with OSA indicated for CPAP treatment compared the efficacy of fixed-pressure CPAP (FP-CPAP) with auto-adjusting CPAP (AutoCPAP) in reducing BP. The primary endpoint was the change in office systolic BP after 4 months. Secondary endpoints included 24 h BP measurements. RESULTS:Patients (322) were randomised to FP-CPAP (n=161) or AutoCPAP (n=161). The mean apnoea+hypopnoea index (AHI) was 43/h (SD, 21); mean age was 57 (SD, 11), with 70% of males; mean body mass index was 31.3 kg/m(2) (SD, 6.6) and median device use was 5.1 h/night. In the intention-to-treat analysis, office systolic blood pressure decreased by 2.2 mm Hg (95% CI -5.8 to 1.4) and 0.4 mm Hg (-4.3 to 3.4) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.3 mm Hg (95% CI -4.1 to 1.5); p=0.37, adjusted for baseline BP values). 24 h diastolic BP (DBP) decreased by 1.7 mm Hg (95% CI -3.9 to 0.5) and 0.5 mm Hg (95% CI -2.3 to 1.3) in the FP-CPAP and AutoCPAP group, respectively (group difference: -1.4 mm Hg (95% CI -2.7 to -0.01); p=0.048, adjusted for baseline BP values). CONCLUSIONS: The result was negative regarding the primary outcome of office BP, while FP-CPAP was more effective in reducing 24 h DBP (a secondary outcome). TRIAL REGISTRATION NUMBER: NCT01090297. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/
Authors: Susheel P Patil; Indu A Ayappa; Sean M Caples; R Joh Kimoff; Sanjay R Patel; Christopher G Harrod Journal: J Clin Sleep Med Date: 2019-02-15 Impact factor: 4.062