Do autologous blood transfusion systems reduce allogeneic blood transfusion in total knee arthroplasty?

Aditya Pawaskar1, Abhijeet Ashok Salunke2, Aashay Kekatpure3, Yongsheng Chen4, G I Nambi5, Junhao Tan4, Dhiraj Sonawane6, Subodhkumar Pathak7.   

Abstract

PURPOSE: To study whether autologus blood transfusion systems reduce the requirement of allogneic blood transfusion in patients undergoing total knee arthroplasty.
METHODS: A comprehensive search of the published literature with PubMed, Scopus and Science direct database was performed. The following search terms were used: (total knee replacement) OR (total knee arthroplasty) OR (TKA) AND (blood transfusion) OR (autologous transfusion) OR (autologous transfusion system). Using search syntax, a total of 748 search results were obtained (79 from PubMed, 586 from Science direct and 83 from Scopus). Twenty-one randomized control trials were included for this meta-analysis.
RESULTS: The allogenic transfusion rate in autologus blood transfusion (study) group was significantly lower than the control group (28.4 and 53.5 %, respectively) (p value 0.0001, Relative risk: 0.5). The median units of allogenic blood transfused in study control group and control group were 0.1 (0.1-3.0) and 1.3 (0.3-2.6), respectively. The median hospital stay in study group was 9 (6.7-15.6) days and control group was 8.7 (6.6-16.7) days. The median cost incurred for blood transfusion per patient in study and control groups was 175 (85.7-260) and 254.7 (235-300) euros, respectively.
CONCLUSION: This meta-analysis demonstrates that the use of auto-transfusion systems is a cost-effective method to reduce the need for and quantity of allogenic transfusion in elective total knee arthroplasty. LEVEL OF EVIDENCE: Level I.

Entities:  

Keywords:  Allogenic blood transfusion; Autologous transfusion; Autologous transfusion system; Meta-analysis; Randomized control trials; Total knee arthroplasty

Mesh:

Year:  2016        PMID: 27085359     DOI: 10.1007/s00167-016-4116-z

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  35 in total

Review 1.  Strategies for minimizing blood loss in orthopedic surgery.

Authors:  Joseph D Tobias
Journal:  Semin Hematol       Date:  2004-01       Impact factor: 3.851

2.  Clinical efficacy of postoperative autologous transfusion of filtered shed blood in hip and knee arthroplasty.

Authors:  D Strümper; E W G Weber; S Gielen-Wijffels; R Van Drumpt; S Bulstra; R Slappendel; M E Durieux; M A E Marcus
Journal:  Transfusion       Date:  2004-11       Impact factor: 3.157

3.  Allogenic versus autologous transfusions: comparison of results following primary total knee replacement.

Authors:  Thomas Apostolou; Elias Fotiadis; Efthimios Samoladas; Anastasios Christodoulou; Panagiotis Akritopoulos; Ioannis Notaras
Journal:  Orthopedics       Date:  2007-03       Impact factor: 1.390

4.  Autologous re-transfusion drain compared with no drain in total knee arthroplasty: a randomised controlled trial.

Authors:  Wieger Horstmann; Bart Kuipers; David Ohanis; Robert Slappendel; Boudewijn Kollen; Cees Verheyen
Journal:  Blood Transfus       Date:  2013-07-26       Impact factor: 3.443

5.  A prospective randomised controlled trial of autologous retransfusion in total knee replacement.

Authors:  A Amin; A Watson; J Mangwani; D H Nawabi; D Nawabi; R Ahluwalia; M Loeffler
Journal:  J Bone Joint Surg Br       Date:  2008-04

6.  Efficacy, safety and user-friendliness of two devices for postoperative autologous shed red blood cell re-infusion in elective orthopaedic surgery patients: A randomized pilot study.

Authors:  C So-Osman; R G H H Nelissen; H C J Eikenboom; A Brand
Journal:  Transfus Med       Date:  2006-10       Impact factor: 2.019

7.  Postoperative re-perfusion of drained blood in patients undergoing total knee arthroplasty: is it effective and cost-efficient?

Authors:  John M Kirkos; Christos Th Krystallis; Panayotis A Konstantinidis; Kyriakos A Papavasiliou; Margaritis J Kyrkos; Lazaros G Ikonomidis
Journal:  Acta Orthop Belg       Date:  2006-01       Impact factor: 0.500

8.  Autotransfusion drains in total knee replacement. Are they alternatives to homologous transfusion?

Authors:  T Abuzakuk; V Senthil Kumar; Y Shenava; C Bulstrode; J A Skinner; S R Cannon; T W Briggs
Journal:  Int Orthop       Date:  2006-06-08       Impact factor: 3.075

9.  A randomized trial on the efficacy of an autologous blood drainage and transfusion device in patients undergoing elective knee arthroplasty.

Authors:  N M Heddle; W T Brox; L N Klama; L L Dickson; M N Levine
Journal:  Transfusion       Date:  1992-10       Impact factor: 3.157

10.  Post-operative auto-transfusion in total hip or knee arthroplasty: a meta-analysis of randomized controlled trials.

Authors:  Zhao Haien; Jiang Yong; Ma Baoan; Guo Mingjun; Fan Qingyu
Journal:  PLoS One       Date:  2013-01-25       Impact factor: 3.240

View more
  10 in total

1.  Effects of stored autotransfusion on electrolytes and postoperative complications in patients undergoing elective orthopedic surgery.

Authors:  Zongzheng Han; Min Wang; Shuhong Yu
Journal:  Am J Transl Res       Date:  2021-06-15       Impact factor: 4.060

2.  Does blood transfusion type affect complication and length of stay following same-day bilateral total knee arthroplasty?

Authors:  Vasileios G Soranoglou; Lazaros A Poultsides; Florian Wanivenhaus; Allina A Nocon; Georgios K Triantafyllopoulos; Peter K Sculco; Stavros G Memtsoudis; Thomas P Sculco
Journal:  J Orthop       Date:  2018-02-21

3.  Risk factors analysis and nomogram construction for blood transfusion in elderly patients with femoral neck fractures undergoing hemiarthroplasty.

Authors:  Jian Zhu; Hongzhi Hu; Xiangtian Deng; Xiaodong Cheng; Yonglong Li; Wei Chen; Yingze Zhang
Journal:  Int Orthop       Date:  2022-02-15       Impact factor: 3.479

4.  Intravenous Ferric Carboxymaltose Improves Response to Postoperative Anemia Following Total Knee Arthroplasty: A Prospective Randomized Controlled Trial in Asian Cohort.

Authors:  Keun Young Choi; In Jun Koh; Man Soo Kim; Chulkyu Kim; Yong In
Journal:  J Clin Med       Date:  2022-04-22       Impact factor: 4.964

5.  No benefit of autologous transfusion drains in total knee arthroplasty.

Authors:  Christoph Schnurr; Ioannis Giannakopoulos; Dariusch Arbab; Jens Dargel; Johannes Beckmann; Peer Eysel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06-02       Impact factor: 4.342

6.  Serum Levels of VWF, t-PA, TNF-α, and ICAM-1 in Patients Receiving Hemocoagulase Combined with Platelet-Rich Plasma during Total Hip Replacement.

Authors:  Yaobin Huang; Bin Zhou; Yu Chen
Journal:  Genet Res (Camb)       Date:  2022-01-27       Impact factor: 1.588

7.  Prospective study of preoperative autologous blood donation for patients with high risk of allogeneic blood transfusion in lumbar fusion surgery: a study protocol of a randomised controlled trial.

Authors:  Nanfang Xu; Youyu Zhang; Yun Tian; Baohua Li; Haiqin Qiao; Xiaoqing Zhang; Nan Yang; Wei Li; Chao Zhang; Weishi Li; Wei Fu
Journal:  BMJ Open       Date:  2022-02-15       Impact factor: 2.692

8.  Does Autologous Transfusion Decrease Allogeneic Transfusion in Liposuction Surgery of Lymphedema Patients?

Authors:  Linfeng Chen; Kun Chang; Yan Chen; Zhenhua Xu; Wenbin Shen
Journal:  Front Med (Lausanne)       Date:  2022-04-05

9.  Surgical vacuum filter-derived stromal cells are superior in proliferation to human bone marrow aspirate.

Authors:  Katharina Henze; Monika Herten; Marcel Haversath; André Busch; Sven Brandau; Alexander Hackel; Stefanie B Flohé; Marcus Jäger
Journal:  Stem Cell Res Ther       Date:  2019-11-21       Impact factor: 6.832

10.  Reduction of Blood Loss by Intra-articular Injection of Tranexamic Acid Combined with Knee and Hip Flexion at 45° During Primary Total Knee Arthroplasty: A Randomized Controlled Trial.

Authors:  Jian-Qi Yang; Lin Yang; Jian-Shao Tan; Kun-Ping Huo; Liang Zhao; Dao-Zhang Cai
Journal:  Orthop Surg       Date:  2020-10-22       Impact factor: 2.071

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.