Literature DB >> 27078055

Can We Use the Fellow Eye Biometric Data to Predict IOL Power?

Maddalena De Bernardo1, Lucio Zeppa2, Raimondo Forte1, Michela Cennamo1, Luisa Caliendo1, Lucia Zeppa2, Nicola Rosa1.   

Abstract

PURPOSE: To study the correlation between right (RE) and left eye (LE) keratometry readings (K) and axial lengths (AL) in a population-based sample of normal subjects.
METHODS: In a cross-sectional retrospective study conducted at S. Giuseppe Moscati Hospital, Avellino, Italy, 4516 eyes of 2258 patients with a mean age of 67 ± 16.36 years (range 18-96 years) were included. Partial coherence interferometry data obtained in right (RE) and left (LE) eyes were analyzed and correlated.
RESULTS: The average K was 44.01 ± 1.50 diopters (D) (range 39.09-49.89 D) in the RE and 44.04 ± 1.53 D (range 39.63-51.89 D) in the LE (p = 0.0075). 4.5% of the patients (101) presented with differences in the corneal power ≥ 1 D, corresponding to a difference of roughly 1 D in the IOL power. The average AL was 23.89 ± 1.77 mm (range 19.09-35.15 mm) in the RE and 23.84 ± 1.68 mm (range 19.23-35.04 mm) in the LE (p = 0.0018). 19.2% of the patients (433) presented with differences in the AL ≥ 0.4 mm, corresponding to a difference of roughly 1 D in the IOL power.
CONCLUSIONS: In calculating the IOL power, we must be aware of these results when we measure the fellow eye to validate the measurements in the first eye. In the case of postcataract refractive error, the outcome could be used for the second eye only when symmetric biometric findings are present.

Entities:  

Keywords:  Anisometropia; IOL calculation; axial length; keratometry

Mesh:

Year:  2016        PMID: 27078055     DOI: 10.3109/08820538.2015.1096400

Source DB:  PubMed          Journal:  Semin Ophthalmol        ISSN: 0882-0538            Impact factor:   1.975


  7 in total

1.  The binocular intraocular lens power difference in eyes with different axial lengths.

Authors:  Ming-Hui Deng; Xiao-Gang Wang; Song Chen; Xue-Feng Shi
Journal:  Int J Ophthalmol       Date:  2022-06-18       Impact factor: 1.645

2.  Similarity of eyes in a cataractous population-How reliable is the biometry of the fellow eye for lens power calculation?

Authors:  Achim Langenbucher; Nóra Szentmáry; Alan Cayless; Veronika Röggla; Christina Leydolt; Jascha Wendelstein; Peter Hoffmann
Journal:  PLoS One       Date:  2022-06-30       Impact factor: 3.752

3.  Measurement of corneal thickness using Pentacam HR versus Nidek CEM-530 specular microscopy.

Authors:  Maddalena De Bernardo; Palmiro Cornetta; Giuseppe Marotta; Giulio Salerno; Ilaria De Pascale; Nicola Rosa
Journal:  J Int Med Res       Date:  2019-12-26       Impact factor: 1.671

4.  Optical Biometry and Lens Power Calculations in 500 Phakic Patients: Axial Length and Corneal Curvature in the Fellow Eye.

Authors:  Olav Kristianslund; Safia Esmail Hassaf; Liv Drolsum
Journal:  Clin Ophthalmol       Date:  2022-08-23

Review 5.  Nanophthalmos: A Review of the Clinical Spectrum and Genetics.

Authors:  Pedro C Carricondo; Thais Andrade; Lev Prasov; Bernadete M Ayres; Sayoko E Moroi
Journal:  J Ophthalmol       Date:  2018-05-09       Impact factor: 1.909

6.  Inter-ocular and inter-visit differences in ocular biometry and refractive outcomes after cataract surgery.

Authors:  Hyun Sup Choi; Hyo Soon Yoo; Yerim An; Sam Young Yoon; Sung Pyo Park; Yong-Kyu Kim
Journal:  Sci Rep       Date:  2020-09-07       Impact factor: 4.379

7.  Biometric Parameters and Corneal Astigmatism: Differences Between Male and Female Eyes.

Authors:  Maddalena De Bernardo; Lucio Zeppa; Lucia Zeppa; Palmiro Cornetta; Livio Vitiello; Nicola Rosa
Journal:  Clin Ophthalmol       Date:  2020-02-28
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.