Literature DB >> 27070329

Peripheral Venous Waveform Analysis for Detecting Hemorrhage and Iatrogenic Volume Overload in a Porcine Model.

Kyle M Hocking1, Ban Sileshi, Franz J Baudenbacher, Richard B Boyer, Kelly L Kohorst, Colleen M Brophy, Susan S Eagle.   

Abstract

BACKGROUND: Unrecognized hemorrhage and unguided resuscitation is associated with increased perioperative morbidity and mortality. The authors investigated peripheral venous waveform analysis (PIVA) as a method for quantitating hemorrhage as well as iatrogenic fluid overload during resuscitation.
METHODS: The authors conducted a prospective study on Yorkshire Pigs (n = 8) undergoing hemorrhage, autologous blood return, and administration of balanced crystalloid solution beyond euvolemia. Intra-arterial blood pressure, electrocardiogram, and pulse oximetry were applied to each subject. Peripheral venous pressure was measured continuously through an upper extremity standard peripheral IV catheter and analyzed with LabChart. The primary outcome was comparison of change in the first fundamental frequency (f1) of PIVA with standard and invasive monitoring and shock index (SI).
RESULTS: Hemorrhage, return to euvolemia, and iatrogenic fluid overload resulted in significantly non-zero slopes of f1 amplitude. There were no significant differences in heart rate or mean arterial pressure, and a late change in SI. For the detection of hypovolemia the PIVA f1 amplitude change generated an receiver operator curves (ROC) curve with an area under the curve (AUC) of 0.93; heart rate AUC = 0.61; mean arterial pressure AUC = 0.48, and SI AUC = 0.72. For hypervolemia the f1 amplitude generated an ROC curve with an AUC of 0.85, heart rate AUC = 0.62, mean arterial pressure AUC = 0.63, and SI AUC = 0.65.
CONCLUSIONS: In this study, PIVA demonstrated a greater sensitivity for detecting acute hemorrhage, return to euvolemia, and iatrogenic fluid overload compared with standard monitoring and SI. PIVA may provide a low-cost, minimally invasive monitoring solution for monitoring and resuscitating patients with perioperative hemorrhage.

Entities:  

Mesh:

Year:  2016        PMID: 27070329     DOI: 10.1097/SHK.0000000000000615

Source DB:  PubMed          Journal:  Shock        ISSN: 1073-2322            Impact factor:   3.454


  14 in total

1.  Optimizing peripheral venous pressure waveforms in an awake pediatric patient by decreasing signal interference.

Authors:  Patrick C Bonasso; Melvin S Dassinger; Morten O Jensen; Samuel D Smith; Jeffrey M Burford; Kevin W Sexton
Journal:  J Clin Monit Comput       Date:  2018-03-06       Impact factor: 2.502

2.  Critical Information from High Fidelity Arterial and Venous Pressure Waveforms During Anesthesia and Hemorrhage.

Authors:  Lauren D Crimmins-Pierce; Gabriel P Bonvillain; Kaylee R Henry; Md Abul Hayat; Adria Abella Villafranca; Sam E Stephens; Hanna K Jensen; Joseph A Sanford; Jingxian Wu; Kevin W Sexton; Morten O Jensen
Journal:  Cardiovasc Eng Technol       Date:  2022-05-11       Impact factor: 2.495

3.  Noninvasive Venous Waveform Analysis Correlates With Pulmonary Capillary Wedge Pressure and Predicts 30-Day Admission in Patients With Heart Failure Undergoing Right Heart Catheterization.

Authors:  Bret Alvis; Jessica Huston; Jeffery Schmeckpeper; Monica Polcz; Marisa Case; Rene Harder; Jonathan S Whitfield; Kendall G Spears; Meghan Breed; Lexie Vaughn; Colleen Brophy; Kyle M Hocking; Joann Lindenfeld
Journal:  J Card Fail       Date:  2021-09-20       Impact factor: 5.712

Review 4.  Ultrafiltration in critically ill patients treated with kidney replacement therapy.

Authors:  Raghavan Murugan; Rinaldo Bellomo; Paul M Palevsky; John A Kellum
Journal:  Nat Rev Nephrol       Date:  2020-11-11       Impact factor: 28.314

5.  Non-Invasive Venous waveform Analysis (NIVA) for monitoring blood loss in human blood donors and validation in a porcine hemorrhage model.

Authors:  Bret D Alvis; Reid McCallister; Monica Polcz; Jose Lucio O Lima; Jenna Helmer Sobey; Daniel R Brophy; Merrick Miles; Colleen Brophy; Kyle Hocking
Journal:  J Clin Anesth       Date:  2019-11-28       Impact factor: 9.452

Review 6.  Kidney Replacement Therapy for Fluid Management.

Authors:  Vikram Balakumar; Raghavan Murugan
Journal:  Crit Care Clin       Date:  2021-02-13       Impact factor: 3.598

7.  Hemodynamic Parameters in the Assessment of Fluid Status in a Porcine Hemorrhage and Resuscitation Model.

Authors:  Eric S Wise; Kyle M Hocking; Monica E Polcz; Gregory J Beilman; Colleen M Brophy; Jenna H Sobey; Philip J Leisy; Roy K Kiberenge; Bret D Alvis
Journal:  Anesthesiology       Date:  2021-04-01       Impact factor: 7.892

8.  Evaluation of the Stress-Growth Hypothesis in Saphenous Vein Perfusion Culture.

Authors:  David A Prim; Brooks A Lane; Jacopo Ferruzzi; Tarek Shazly; John F Eberth
Journal:  Ann Biomed Eng       Date:  2020-07-29       Impact factor: 3.934

9.  Fast Fourier Transformation of Peripheral Venous Pressure Changes More Than Vital Signs with Hemorrhage.

Authors:  Patrick C Bonasso; Melvin S Dassinger; Brady McLaughlin; Jeffrey M Burford; Kevin W Sexton
Journal:  Mil Med       Date:  2019-03-01       Impact factor: 1.437

10.  Normal Saline solutions cause endothelial dysfunction through loss of membrane integrity, ATP release, and inflammatory responses mediated by P2X7R/p38 MAPK/MK2 signaling pathways.

Authors:  Joyce Cheung-Flynn; Bret D Alvis; Kyle M Hocking; Christy M Guth; Weifeng Luo; Reid McCallister; Kalyan Chadalavada; Monica Polcz; Padmini Komalavilas; Colleen M Brophy
Journal:  PLoS One       Date:  2019-08-14       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.