Very low intravenous contrast volume protocol for computed tomography angiography providing comprehensive cardiac and vascular assessment prior to transcatheter aortic valve replacement in patients with chronic kidney disease.

Todd C Pulerwitz1, Omar K Khalique1, Tamim N Nazif1, Anna Rozenshtein2, Gregory D N Pearson2, Rebecca T Hahn1, Torsten P Vahl1, Susheel K Kodali1, Isaac George3, Martin B Leon1, Belinda D'Souza2, Ming Jack Po4, Andrew J Einstein5.   

Abstract

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a lifesaving procedure for many patients high risk for surgical aortic valve replacement. The prevalence of chronic kidney disease (CKD) is high in this population, and thus a very low contrast volume (VLCV) computed tomography angiography (CTA) protocol providing comprehensive cardiac and vascular imaging would be valuable.
METHODS: 52 patients with severe, symptomatic aortic valve disease, undergoing pre-TAVR CTA assessment from 2013-4 at Columbia University Medical Center were studied, including all 26 patients with CKD (eGFR<30 mL/min) who underwent a novel VLCV protocol (20 mL of iohexol at 2.5 mL/s), and 26 standard-contrast-volume (SCV) protocol patients. Using a 320-slice volumetric scanner, the protocol included ECG-gated volume scanning of the aortic root followed by medium-pitch helical vascular scanning through the femoral arteries. Two experienced cardiologists performed aortic annulus and root measurements. Vascular image quality was assessed by two radiologists using a 4-point scale.
RESULTS: VLCV patients had mean (±SD) age 86 ± 6.5, BMI 23.9 ± 3.4 kg/m(2) with 54% men; SCV patients age 83 ± 8.8, BMI 28.7 ± 5.3 kg/m(2), 65% men. There was excellent intra- and inter-observer agreement for annular and root measurements, and excellent agreement with 3D-transesophageal echocardiographic measurements. Both radiologists found diagnostic-quality vascular imaging in 96% of VLCV and 100% of SCV cases, with excellent inter-observer agreement.
CONCLUSIONS: This study is the first of its kind to report the feasibility and reproducibility of measurements for a VLCV protocol for comprehensive pre-TAVR CTA. There was excellent agreement of cardiac measurements and almost all studies were diagnostic quality for vascular access assessment.
Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Chronic kidney disease; Computed tomography angiography; Transcatheter aortic valve replacement; Very low contrast volume

Mesh:

Substances:

Year:  2016        PMID: 27061253      PMCID: PMC4958553          DOI: 10.1016/j.jcct.2016.03.005

Source DB:  PubMed          Journal:  J Cardiovasc Comput Tomogr        ISSN: 1876-861X


  14 in total

1.  Renal function as predictor of mortality in patients after percutaneous transcatheter aortic valve implantation.

Authors:  Jan-Malte Sinning; Alexander Ghanem; Hannah Steinhäuser; Viktoria Adenauer; Christoph Hammerstingl; Georg Nickenig; Nikos Werner
Journal:  JACC Cardiovasc Interv       Date:  2010-11       Impact factor: 11.195

2.  Ultra-low contrast computed tomographic angiography (CTA) with 20-mL total dose for transcatheter aortic valve implantation (TAVI) planning.

Authors:  Lorenzo Azzalini; Suhny Abbara; Brian B Ghoshhajra
Journal:  J Comput Assist Tomogr       Date:  2014 Jan-Feb       Impact factor: 1.826

3.  Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.

Authors:  Omar K Khalique; Susheel K Kodali; Jean-Michel Paradis; Tamim M Nazif; Mathew R Williams; Andrew J Einstein; Gregory D Pearson; Kishore Harjai; Kendra Grubb; Isaac George; Martin B Leon; Rebecca T Hahn
Journal:  Circ Cardiovasc Imaging       Date:  2013-11-12       Impact factor: 7.792

4.  Transcatheter versus surgical aortic-valve replacement in high-risk patients.

Authors:  Craig R Smith; Martin B Leon; Michael J Mack; D Craig Miller; Jeffrey W Moses; Lars G Svensson; E Murat Tuzcu; John G Webb; Gregory P Fontana; Raj R Makkar; Mathew Williams; Todd Dewey; Samir Kapadia; Vasilis Babaliaros; Vinod H Thourani; Paul Corso; Augusto D Pichard; Joseph E Bavaria; Howard C Herrmann; Jodi J Akin; William N Anderson; Duolao Wang; Stuart J Pocock
Journal:  N Engl J Med       Date:  2011-06-05       Impact factor: 91.245

5.  Two-year outcomes after transcatheter or surgical aortic-valve replacement.

Authors:  Susheel K Kodali; Mathew R Williams; Craig R Smith; Lars G Svensson; John G Webb; Raj R Makkar; Gregory P Fontana; Todd M Dewey; Vinod H Thourani; Augusto D Pichard; Michael Fischbein; Wilson Y Szeto; Scott Lim; Kevin L Greason; Paul S Teirstein; S Chris Malaisrie; Pamela S Douglas; Rebecca T Hahn; Brian Whisenant; Alan Zajarias; Duolao Wang; Jodi J Akin; William N Anderson; Martin B Leon
Journal:  N Engl J Med       Date:  2012-03-26       Impact factor: 91.245

6.  Updated standardized endpoint definitions for transcatheter aortic valve implantation: the Valve Academic Research Consortium-2 consensus document.

Authors:  A Pieter Kappetein; Stuart J Head; Philippe Généreux; Nicolo Piazza; Nicolas M van Mieghem; Eugene H Blackstone; Thomas G Brott; David J Cohen; Donald E Cutlip; Gerrit-Anne van Es; Rebecca T Hahn; Ajay J Kirtane; Mitchell W Krucoff; Susheel Kodali; Michael J Mack; Roxana Mehran; Josep Rodés-Cabau; Pascal Vranckx; John G Webb; Stephan Windecker; Patrick W Serruys; Martin B Leon
Journal:  Eur Heart J       Date:  2012-10       Impact factor: 29.983

7.  Causes and timing of death during long-term follow-up after transcatheter aortic valve replacement.

Authors:  Francesco Saia; Azeem Latib; Cristina Ciuca; Valeria Gasparetto; Massimo Napodano; Alessandro Sticchi; Laura Anderlucci; Cinzia Marrozzini; Toru Naganuma; Ottavio Alfieri; Michela Facchin; Brunilda Hoxha; Carolina Moretti; Antonio Marzocchi; Antonio Colombo; Giuseppe Tarantini
Journal:  Am Heart J       Date:  2014-07-30       Impact factor: 4.749

8.  Low-volume contrast medium protocol for comprehensive cardiac and aortoiliac CT assessment in the context of transcatheter aortic valve replacement.

Authors:  Lucas L Geyer; Carlo Nicola De Cecco; U Joseph Schoepf; Justin R Silverman; Aleksander W Krazinski; Fabian Bamberg; Daniel H Steinberg
Journal:  Acad Radiol       Date:  2015-06-18       Impact factor: 3.173

9.  Feasibility of ultra-low contrast 64-slice computed tomography angiography before transcatheter aortic valve implantation: a real-world experience.

Authors:  Pietro Spagnolo; Manuela Giglio; Daniela Di Marco; Azeem Latib; Francesca Besana; Alaide Chieffo; Matteo Montorfano; Sandro Sironi; Ottavio Alfieri; Antonio Colombo
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2015-07-09       Impact factor: 6.875

10.  Incidence and effect of acute kidney injury after transcatheter aortic valve replacement using the new valve academic research consortium criteria.

Authors:  Philippe Généreux; Susheel K Kodali; Philip Green; Jean-Michel Paradis; Benoit Daneault; Garvey Rene; Irene Hueter; Isaac Georges; Ajay Kirtane; Rebecca T Hahn; Craig Smith; Martin B Leon; Mathew R Williams
Journal:  Am J Cardiol       Date:  2012-10-04       Impact factor: 2.778

View more
  4 in total

Review 1.  Noninvasive aortic imaging.

Authors:  Vinit Baliyan; Daniel Verdini; Nandini M Meyersohn
Journal:  Cardiovasc Diagn Ther       Date:  2018-04

2.  320-row CT transcatheter aortic valve replacement planning with a single reduced contrast media bolus injection.

Authors:  Daddy Mata-Mbemba; Aissam Labani; Soraya El Ghannudi; Mi-Young Jeung; Patrick Ohlmann; Catherine Roy; Mickaël Ohana
Journal:  PLoS One       Date:  2018-09-13       Impact factor: 3.240

Review 3.  Clinical Applications of Wide-Detector CT Scanners for Cardiothoracic Imaging: An Update.

Authors:  Eun Ju Kang
Journal:  Korean J Radiol       Date:  2019-12       Impact factor: 3.500

4.  Optimizing low contrast volume thoracic CT angiography: From the basics to the advanced.

Authors:  Katherine Kaproth-Joslin; Susan Hobbs; Prabhakar Rajiah; Apeksha Chaturvedi; Abhishek Chaturvedi
Journal:  J Clin Imaging Sci       Date:  2022-07-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.