Literature DB >> 27060975

Mixed thread/paper-based microfluidic chips as a platform for glucose assays.

Ariana Gonzalez1, Lissette Estala1, Michelle Gaines1, Frank A Gomez1.   

Abstract

A novel microfluidic thread/paper-based analytical device (μTPAD) to detect glucose through a colorimetric assay is described. The μTPAD was fabricated from nylon thread trifurcated into three channels terminating at analysis sites comprised of circular zones of chromatography paper, which have previously been spotted with glucose of different concentrations. A solution of glucose oxidase (GOx), horseradish peroxidase (HRP), and potassium iodide (KI) is transported via capillary action to the analysis sites where a yellow-brown color is observed indicating oxidation of iodide to iodine. The device was then dried, scanned, and analyzed yielding a correlation between yellow intensity and glucose concentrations. Both a flat platform constructed mainly of tape, and a cone platform constructed from tape and polyvinyl chloride, are described. Studies to quantitate glucose in artificial urine showed good correlation using the μTPAD.
© 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  Glucose oxidase; Point-of-care diagnostic device; Thread/paper microfluidics

Mesh:

Substances:

Year:  2016        PMID: 27060975     DOI: 10.1002/elps.201600029

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  6 in total

1.  Knitting Thread Devices: Detecting Candida albicans Using Napkins and Tampons.

Authors:  Anusha Prabhu; Hardik Singhal; M S Giri Nandagopal; Reshma Kulal; Prakash Peralam Yegneswaran; Naresh Kumar Mani
Journal:  ACS Omega       Date:  2021-05-03

Review 2.  Recent innovations in cost-effective polymer and paper hybrid microfluidic devices.

Authors:  Wan Zhou; Maowei Dou; Sanjay S Timilsina; Feng Xu; XiuJun Li
Journal:  Lab Chip       Date:  2021-07-13       Impact factor: 7.517

3.  Workshop, Cost-Effective and Streamlined Fabrications of Re-Usable World-To-Chip Connectors for Handling Sample of Limited Volume and for Assembling Chip Array.

Authors:  Jiann-Hwa Lue; Yu-Sheng Su; Tai-Chih Kuo
Journal:  Sensors (Basel)       Date:  2018-12-01       Impact factor: 3.576

4.  MOMSense: Metal-Oxide-Metal Elementary Glucose Sensor.

Authors:  Heba Abunahla; Baker Mohammad; Anas Alazzam; Maguy Abi Jaoude; Mahmoud Al-Qutayri; Sabina Abdul Hadi; Said F Al-Sarawi
Journal:  Sci Rep       Date:  2019-04-02       Impact factor: 4.379

Review 5.  Recent advances in thread-based microfluidics for diagnostic applications.

Authors:  Xuan Weng; Yuejun Kang; Qian Guo; Bei Peng; Hai Jiang
Journal:  Biosens Bioelectron       Date:  2019-03-08       Impact factor: 10.618

6.  Thread integrated smart-phone imaging facilitates early turning point colorimetric assay for microbes.

Authors:  Anusha Prabhu; Giri Nandagopal M S; Prakash Peralam Yegneswaran; Vijendra Prabhu; Ujjwal Verma; Naresh Kumar Mani
Journal:  RSC Adv       Date:  2020-07-17       Impact factor: 4.036

  6 in total