Literature DB >> 2705827

Treatment of malignant ventricular arrhythmias with the automatic implantable cardioverter defibrillator.

A D Slater1, I Singer, C S Stavens, C Zee-Cheng, B L Ganzel, J Kupersmith, C Mavroudis, L A Gray.   

Abstract

Twenty-eight patients with malignant ventricular arrhythmias were treated with the automatic implantable cardioverter-defibrillator (AICD) in a 14-month period. Thirteen patients were resuscitated from a ventricular fibrillation (VF) episode. Fifteen patients presented with ventricular tachycardia (VT) refractory to medical therapy. The etiology was coronary artery disease in 23 of 28 patients (82%), dilated cardiomyopathy in 2 of 28 patients (7%), sarcoidosis in 2 of 28 patients, and 1 patient in 28 had lupus erythmatosis. The mean left ventricular ejection fraction was 29%. A total of 27 of 28 patients (96%) patients had inducible ventricular tachycardia using programmed stimulation. The patients considered for AICD implant failed a mean of 3.6 antiarrhythmic drugs. Rate counting and defibrillating leads were inserted through a lateral thoracotomy in 17 patients and a mediansternotomy incision in 11 patients in conjunction with another cardiac procedure in 10 patients. The generators were positioned in a subcutaneous pocket beneath the left costal margin. There were no operative deaths. The mean follow-up was 6.7 months (range 1 to 14) with no VT/VF deaths in patients with defibrillators. The study demonstrated that AICD is an effective device for prevention of sudden cardiac death.

Entities:  

Mesh:

Year:  1989        PMID: 2705827      PMCID: PMC1494071          DOI: 10.1097/00000658-198905000-00017

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  28 in total

1.  Personnel and equipment required for electrophysiologic testing. Report of the Committee on Electrocardiography and Cardian Electrophysiology, Council on Clinical Cardiology, the American Heart Association.

Authors:  L S Gettes; D P Zipes; P C Gillette; M E Josephson; M M Laks; D M Mirvis; M M Scheinman; L T Sheffield; D Wu
Journal:  Circulation       Date:  1984-06       Impact factor: 29.690

2.  Clinical characteristics of sudden death: implications for survival.

Authors:  R J Myerburg; L Zaman; R M Luceri; K M Kessler; D Estes; R Trohman; J Horgan; A Castellanos
Journal:  Cardiovasc Clin       Date:  1985

Review 3.  Initiating events of sudden cardiac death.

Authors:  I P Panidis; J Morganroth
Journal:  Cardiovasc Clin       Date:  1985

4.  The implanted defibrillator: relation of defibrillating lead configuration and clinical variables to defibrillation threshold.

Authors:  P J Troup; P D Chapman; G N Olinger; L H Kleinman
Journal:  J Am Coll Cardiol       Date:  1985-12       Impact factor: 24.094

5.  Survival of out-of-hospital cardiac arrest with early initiation of cardiopulmonary resuscitation.

Authors:  R O Cummins; M S Eisenberg; A P Hallstrom; P E Litwin
Journal:  Am J Emerg Med       Date:  1985-03       Impact factor: 2.469

6.  Comparative efficacy of transvenous cardioversion and pacing in patients with sustained ventricular tachycardia: a prospective, randomized, crossover study.

Authors:  S Saksena; P Chandran; Y Shah; R Boccadamo; D Pantopoulos; S T Rothbart
Journal:  Circulation       Date:  1985-07       Impact factor: 29.690

7.  Cardiac arrest treated with a new automatic external defibrillator by out-of-hospital first responders.

Authors:  W D Weaver; M K Copass; D L Hill; C Fahrenbruch; A P Hallstrom; L A Cobb
Journal:  Am J Cardiol       Date:  1986-05-01       Impact factor: 2.778

8.  The automatic implantable cardioverter-defibrillator: efficacy, complications, and device failures.

Authors:  F E Marchlinski; B T Flores; A E Buxton; W C Hargrove; V P Addonizio; L W Stephenson; A H Harken; J U Doherty; E W Grogan; M E Josephson
Journal:  Ann Intern Med       Date:  1986-04       Impact factor: 25.391

9.  Usefulness of electrophysiologic testing in evaluation of amiodarone therapy for sustained ventricular tachyarrhythmias associated with coronary heart disease.

Authors:  L N Horowitz; A M Greenspan; S R Spielman; C R Webb; J Morganroth; H Rotmensch; N M Sokoloff; A P Rae; B L Segal; H R Kay
Journal:  Am J Cardiol       Date:  1985-02-01       Impact factor: 2.778

10.  The automatic implantable cardioverter-defibrillator: results, observations, and comments.

Authors:  R M Luceri; R J Thurer; G M Palatianos; P R Fernandez; A el-Shalakany; A Castellanos
Journal:  Pacing Clin Electrophysiol       Date:  1986-11       Impact factor: 1.976

View more
  1 in total

1.  Operative risks of the implantable defibrillator versus endocardial resection.

Authors:  I L Kron; D E Haines; C G Tribble; L H Blackbourne; T L Flanagan; C E Hobson; J P DiMarco
Journal:  Ann Surg       Date:  1990-05       Impact factor: 12.969

  1 in total