Literature DB >> 27056422

Quiet T1-Weighted Pointwise Encoding Time Reduction with Radial Acquisition for Assessing Myelination in the Pediatric Brain.

N Aida1, T Niwa2, Y Fujii1, K Nozawa1, M Enokizono1, K Murata3, T Obata4.   

Abstract

BACKGROUND AND
PURPOSE: T1-weighted pointwise encoding time reduction with radial acquisition (PETRA) sequences require limited gradient activity and allow quiet scanning. We aimed to assess the usefulness of PETRA in pediatric brain imaging.
MATERIALS AND METHODS: We included consecutive pediatric patients who underwent both MPRAGE and PETRA. The contrast-to-noise and contrast ratios between WM and GM were compared in the cerebellar WM, internal capsule, and corpus callosum. The degree of myelination was rated by using 4-point scales at each of these locations plus the subcortical WM in the anterior frontal, anterior temporal, and posterior occipital lobes. Two radiologists made all assessments, and the intra- and interrater agreement was calculated by using intraclass correlation coefficients. Acoustic noise on MPRAGE and PETRA was measured.
RESULTS: We included 56 patients 5 days to 14 years of age (mean age, 36.6 months) who underwent both MPRAGE and PETRA. The contrast-to-noise and contrast ratios for PETRA were significantly higher than those for MPRAGE (P < .05), excluding the signal ratio for cerebellar WM. Excellent intra- and interrater agreement were obtained for myelination at all locations except the cerebellar WM. The acoustic noise on PETRA (58.2 dB[A]) was much lower than that on MPRAGE (87.4 dB[A]).
CONCLUSIONS: PETRA generally showed better objective imaging quality without a difference in subjective image-quality evaluation and produced much less acoustic noise compared with MPRAGE. We conclude that PETRA can substitute for MPRAGE in pediatric brain imaging.
© 2016 by American Journal of Neuroradiology.

Entities:  

Mesh:

Year:  2016        PMID: 27056422     DOI: 10.3174/ajnr.A4747

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  8 in total

1.  Characterization of hardware-related spatial distortions for IR-PETRA pulse sequence using a brain specific phantom.

Authors:  Sima Ahmadian; Iraj Jabbari; Seyed Mehdi Bagherimofidi; Hamidreza Saligheh Rad
Journal:  MAGMA       Date:  2020-07-06       Impact factor: 2.310

2.  MR Imaging of the Facial Nerve through the Temporal Bone at 3T with a Noncontrast Ultrashort Echo Time Sequence.

Authors:  J P Guenette; R T Seethamraju; J Jayender; C E Corrales; T C Lee
Journal:  AJNR Am J Neuroradiol       Date:  2018-08-23       Impact factor: 3.825

3.  Silent susceptibility-weighted angiography to detect hemorrhagic lesions in the brain: a clinical and phantom study.

Authors:  Takuya Fujiwara; Yoshiyuki Watanabe; Hisashi Tanaka; Hiroto Takahashi; Chisato Matsuo; Masahiro Fujiwara; Tetsuya Wakayama; Pauline Worters; Christopher J Hardy; Noriyuki Tomiyama
Journal:  Neuroradiology       Date:  2019-11-06       Impact factor: 2.804

4.  Comparison of contrast-enhanced T1-weighted imaging using DANTE-SPACE, PETRA, and MPRAGE: a clinical evaluation of brain tumors at 3 Tesla.

Authors:  Zi-Qiao Lei; Chuan-Sheng Zheng; Qing Fu; Qi-Guang Cheng; Xiang-Chuang Kong; Ding-Xi Liu; Yi-Hao Guo; John Grinstead; Xiao-Yong Zhang
Journal:  Quant Imaging Med Surg       Date:  2022-01

5.  Pointwise encoding time reduction with radial acquisition in subtraction-based magnetic resonance angiography to assess saccular unruptured intracranial aneurysms at 3 Tesla.

Authors:  Qing Fu; Ding-Xi Liu; Xiao-Yong Zhang; Xian-Bo Deng; Chuan-Sheng Zheng
Journal:  Neuroradiology       Date:  2020-08-13       Impact factor: 2.804

6.  Comparison of Silent and Conventional MR Imaging for the Evaluation of Myelination in Children.

Authors:  Chisato Matsuo-Hagiyama; Yoshiyuki Watanabe; Hisashi Tanaka; Hiroto Takahashi; Atsuko Arisawa; Eri Yoshioka; Shin Nabatame; Sayaka Nakano; Noriyuki Tomiyama
Journal:  Magn Reson Med Sci       Date:  2016-10-31       Impact factor: 2.471

7.  Imaging of Cystic Lung Lesions in Infants Using Pointwise Encoding Time Reduction with Radial Acquisition (PETRA).

Authors:  Kumiko Nozawa; Tetsu Niwa; Noriko Aida
Journal:  Magn Reson Med Sci       Date:  2018-12-03       Impact factor: 2.471

8.  Image quality and subject experience of quiet T1-weighted 7-T brain imaging using a silent gradient coil.

Authors:  Sarah M Jacobs; Edwin Versteeg; Anja G van der Kolk; Leonie N C Visser; Ícaro A F Oliveira; Emiel van Maren; Dennis W J Klomp; Jeroen C W Siero
Journal:  Eur Radiol Exp       Date:  2022-08-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.