Literature DB >> 27053838

In vitro comparative assessment of the mechanical properties of PMMA cement and a GPC cement for vertebroplasty.

Omar Ali Abouazza1, Finbarr Condon2, Ailish Hannigan3, Colum Dunne3.   

Abstract

AIMS: To develop a Glass Polyalkenoate Cement that is suitable for vertebroplasty.
METHODS: Testing was carried out to assess the effect of gamma irradiation used for sterilisation, on the glass transition temperature as well as its mechanical properties, including compressive strength and biflexural strength in vivo as well as testing GPC and PMMA cements post injection in cadaveric human vertebral bone.
RESULTS: There was a trend to a higher failure load required for the GPC cement group compared to the current standard PMMA injected group but this was not statistically significant with this small sample size.
CONCLUSION: The results are encouraging for future research to continue on GPC cements for use in vertebroplasty.

Entities:  

Keywords:  Biflexural strength; Compressive strength; Glass Polyalkenoate Cement; Polymethylmethacrylate; Vertebroplasty

Year:  2016        PMID: 27053838      PMCID: PMC4805853          DOI: 10.1016/j.jor.2016.01.002

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  16 in total

1.  Incidence of clinically diagnosed vertebral fractures: a population-based study in Rochester, Minnesota, 1985-1989.

Authors:  C Cooper; E J Atkinson; W M O'Fallon; L J Melton
Journal:  J Bone Miner Res       Date:  1992-02       Impact factor: 6.741

2.  Resin-modified glass-ionomer setting reaction competition.

Authors:  D W Berzins; S Abey; M C Costache; C A Wilkie; H W Roberts
Journal:  J Dent Res       Date:  2010-01       Impact factor: 6.116

3.  IR and NMR analyses of hardening and maturation of glass-ionomer cement.

Authors:  S Matsuya; T Maeda; M Ohta
Journal:  J Dent Res       Date:  1996-12       Impact factor: 6.116

4.  Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty.

Authors:  M A Liebschner; W S Rosenberg; T M Keaveny
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

5.  The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior.

Authors:  S M Belkoff; J M Mathis; L E Jasper; H Deramond
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

Review 6.  Incidence of subsequent vertebral fracture after kyphoplasty.

Authors:  David Fribourg; Chris Tang; Parveen Sra; Rick Delamarter; Hyun Bae
Journal:  Spine (Phila Pa 1976)       Date:  2004-10-15       Impact factor: 3.468

7.  A randomized trial of vertebroplasty for osteoporotic spinal fractures.

Authors:  David F Kallmes; Bryan A Comstock; Patrick J Heagerty; Judith A Turner; David J Wilson; Terry H Diamond; Richard Edwards; Leigh A Gray; Lydia Stout; Sara Owen; William Hollingworth; Basavaraj Ghdoke; Deborah J Annesley-Williams; Stuart H Ralston; Jeffrey G Jarvik
Journal:  N Engl J Med       Date:  2009-08-06       Impact factor: 91.245

8.  A randomized trial of vertebroplasty for painful osteoporotic vertebral fractures.

Authors:  Rachelle Buchbinder; Richard H Osborne; Peter R Ebeling; John D Wark; Peter Mitchell; Chris Wriedt; Stephen Graves; Margaret P Staples; Bridie Murphy
Journal:  N Engl J Med       Date:  2009-08-06       Impact factor: 91.245

9.  [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty].

Authors:  P Galibert; H Deramond; P Rosat; D Le Gars
Journal:  Neurochirurgie       Date:  1987       Impact factor: 1.553

10.  A randomised sham controlled trial of vertebroplasty for painful acute osteoporotic vertebral fractures (VERTOS IV).

Authors:  Cristina Firanescu; Paul Nm Lohle; Jolanda de Vries; Caroline A Klazen; Job R Juttmann; William Clark; Willem Jan van Rooij
Journal:  Trials       Date:  2011-04-05       Impact factor: 2.279

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.