Implantable Cardioverter-Defibrillator Shock after Stenting Across the Device Leads.

Sanjay Mehra, Mihail Gabriel Chelu.   

Abstract

A 45-year-old man with nonischemic cardiomyopathy and end-stage renal disease had lived uneventfully with a cardiac resynchronization therapy defibrillator (CRT-D) for 5 years. Less than a month before presenting at our institution, he had undergone stenting of his partially occluded subclavian vein, to relieve stenosis of the ipsilateral arteriovenous fistula that was used for his hemodialysis. The CRT-D subsequently discharged. Device interrogation revealed that electrical noise originating from leads damaged by the stent had caused the inappropriate shock and intermittent electrical discharges thereafter. The patient was highly traumatized by these events and insisted upon device removal, which deprived him of a potentially life-saving intervention. He later had a cardiac arrest that resulted in sustained profound hypoxic ischemic encephalopathy with minimal neurologic recovery: his family placed him in a long-term care facility on ventilator support, with a tracheostomy and feeding tube. This situation might have been avoided through collaboration between the interventional radiologist and the electrophysiologist. To our knowledge, this is the first report of a patient with nonischemic cardiomyopathy and end-stage renal disease who presented with inappropriate defibrillator discharge caused by lead damage secondary to stenting across the leads.

Entities:  

Keywords:  Cardiac pacing, artificial; death, sudden, cardiac/prevention & control; defibrillators, implantable/adverse effects; device removal/education; equipment failure; kidney failure, chronic/therapy; prosthesis implantation/adverse effects; stents/adverse effects; stress, psychological/etiology; treatment refusal

Mesh:

Year:  2016        PMID: 27047295      PMCID: PMC4810596          DOI: 10.14503/THIJ-14-4759

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  8 in total

1.  Inappropriate implantable cardioverter-defibrillator shocks: incidence, predictors, and impact on mortality.

Authors:  Johannes B van Rees; C Jan Willem Borleffs; Mihály K de Bie; Theo Stijnen; Lieselot van Erven; Jeroen J Bax; Martin J Schalij
Journal:  J Am Coll Cardiol       Date:  2011-02-01       Impact factor: 24.094

2.  Percutaneous extraction of stented device leads.

Authors:  Bryan Baranowski; Oussama Wazni; Roy Chung; David O Martin; John Rickard; Christine Tanaka-Esposito; Mohammed Bassiouny; Bruce L Wilkoff
Journal:  Heart Rhythm       Date:  2011-12-17       Impact factor: 6.343

3.  Transvenous lead extraction: Heart Rhythm Society expert consensus on facilities, training, indications, and patient management: this document was endorsed by the American Heart Association (AHA).

Authors:  Bruce L Wilkoff; Charles J Love; Charles L Byrd; Maria Grazia Bongiorni; Roger G Carrillo; George H Crossley; Laurence M Epstein; Richard A Friedman; Charles E H Kennergren; Przemyslaw Mitkowski; Raymond H M Schaerf; Oussama M Wazni
Journal:  Heart Rhythm       Date:  2009-05-22       Impact factor: 6.343

4.  Central vein stenosis or occlusion associated with cardiac rhythm management device leads in hemodialysis patients with ipsilateral arteriovenous access: a retrospective study of treatment using stents or stent-grafts.

Authors:  Theodore F Saad; G Robert Myers; Jeffrey Cicone
Journal:  J Vasc Access       Date:  2010 Oct-Dec       Impact factor: 2.283

5.  A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias.

Authors: 
Journal:  N Engl J Med       Date:  1997-11-27       Impact factor: 91.245

6.  A randomized study of the prevention of sudden death in patients with coronary artery disease. Multicenter Unsustained Tachycardia Trial Investigators.

Authors:  A E Buxton; K L Lee; J D Fisher; M E Josephson; E N Prystowsky; G Hafley
Journal:  N Engl J Med       Date:  1999-12-16       Impact factor: 91.245

7.  Managing superior vena cava syndrome as a complication of pacemaker implantation: a pooled analysis of clinical practice.

Authors:  Robert F Riley; Steffen E Petersen; John D Ferguson; Yaver Bashir
Journal:  Pacing Clin Electrophysiol       Date:  2009-12-28       Impact factor: 1.976

8.  Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy.

Authors:  Alan Kadish; Alan Dyer; James P Daubert; Rebecca Quigg; N A Mark Estes; Kelley P Anderson; Hugh Calkins; David Hoch; Jeffrey Goldberger; Alaa Shalaby; William E Sanders; Andi Schaechter; Joseph H Levine
Journal:  N Engl J Med       Date:  2004-05-20       Impact factor: 91.245

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.