Literature DB >> 27045694

Interrogation of Patient Smartphone Activity Tracker to Assist Arrhythmia Management.

Joshua Rudner1, Carol McDougall2, Vivek Sailam2, Monika Smith3, Alfred Sacchetti4.   

Abstract

A 42-year-old man presented to the emergency department (ED) with newly diagnosed atrial fibrillation of unknown duration. Interrogation of the patient's wrist-worn activity tracker and smartphone application identified the onset of the arrhythmia as within the previous 3 hours, permitting electrocardioversion and discharge of the patient from the ED.
Copyright © 2016 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27045694     DOI: 10.1016/j.annemergmed.2016.02.039

Source DB:  PubMed          Journal:  Ann Emerg Med        ISSN: 0196-0644            Impact factor:   5.721


  8 in total

1.  Evaluation of Commercial-Off-The-Shelf Wrist Wearables to Estimate Stress on Students.

Authors:  Francisco de Arriba Pérez; Juan M Santos-Gago; Manuel Caeiro-Rodríguez; Manuel J Fernández Iglesias
Journal:  J Vis Exp       Date:  2018-06-16       Impact factor: 1.355

2.  Pulse Arrival Time Based Cuff-Less and 24-H Wearable Blood Pressure Monitoring and its Diagnostic Value in Hypertension.

Authors:  Yali Zheng; Carmen C Y Poon; Bryan P Yan; James Y W Lau
Journal:  J Med Syst       Date:  2016-07-22       Impact factor: 4.460

3.  Prediction of oxygen uptake dynamics by machine learning analysis of wearable sensors during activities of daily living.

Authors:  T Beltrame; R Amelard; A Wong; R L Hughson
Journal:  Sci Rep       Date:  2017-04-05       Impact factor: 4.379

Review 4.  Wearable Devices in Clinical Trials: Hype and Hypothesis.

Authors:  Elena S Izmailova; John A Wagner; Eric D Perakslis
Journal:  Clin Pharmacol Ther       Date:  2018-04-02       Impact factor: 6.875

Review 5.  The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review.

Authors:  Ka Hou Christien Li; Francesca Anne White; Gary Tse; Timothy Tipoe; Tong Liu; Martin Cs Wong; Aaron Jesuthasan; Adrian Baranchuk; Bryan P Yan
Journal:  JMIR Mhealth Uhealth       Date:  2019-02-15       Impact factor: 4.773

Review 6.  Using wearable technology to predict health outcomes: a literature review.

Authors:  Jason P Burnham; Chenyang Lu; Lauren H Yaeger; Thomas C Bailey; Marin H Kollef
Journal:  J Am Med Inform Assoc       Date:  2018-09-01       Impact factor: 4.497

7.  Wearable technology to inform the prediction and diagnosis of cardiorespiratory events: a scoping review.

Authors:  Hamzeh Khundaqji; Wayne Hing; James Furness; Mike Climstein
Journal:  PeerJ       Date:  2021-12-22       Impact factor: 2.984

8.  Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

Authors:  Ryan R Kroll; J Gordon Boyd; David M Maslove
Journal:  J Med Internet Res       Date:  2016-09-20       Impact factor: 5.428

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.