Erin K Englund1, Zachary B Rodgers2, Michael C Langham2, Emile R Mohler3, Thomas F Floyd4, Felix W Wehrli2. 1. Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. eenglund@mail.med.upenn.edu. 2. Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania, USA. 3. Department of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA. 4. Department of Anesthesiology, Stony Brook University, Stony Brook, New York, USA.
Abstract
PURPOSE: To compare calf skeletal muscle perfusion measured with pulsed arterial spin labeling (PASL) and pseudo-continuous arterial spin labeling (pCASL) methods, and to assess the variability of pCASL labeling efficiency in the popliteal artery throughout an ischemia-reperfusion paradigm. MATERIALS AND METHODS: At 3T, relative pCASL labeling efficiency was experimentally assessed in five subjects by measuring the signal intensity of blood in the popliteal artery just distal to the labeling plane immediately following pCASL labeling or control preparation pulses, or without any preparation pulses throughout separate ischemia-reperfusion paradigms. The relative label and control efficiencies were determined during baseline, hyperemia, and recovery. In a separate cohort of 10 subjects, pCASL and PASL sequences were used to measure reactive hyperemia perfusion dynamics. RESULTS: Calculated pCASL labeling and control efficiencies did not differ significantly between baseline and hyperemia or between hyperemia and recovery periods. Relative to the average baseline, pCASL label efficiency was 2 ± 9% lower during hyperemia. Perfusion dynamics measured with pCASL and PASL did not differ significantly (P > 0.05). Average leg muscle peak perfusion was 47 ± 20 mL/min/100g or 50 ± 12 mL/min/100g, and time to peak perfusion was 25 ± 3 seconds and 25 ± 7 seconds from pCASL and PASL data, respectively. Differences of further metrics parameterizing the perfusion time course were not significant between pCASL and PASL measurements (P > 0.05). CONCLUSION: No change in pCASL labeling efficiency was detected despite the almost 10-fold increase in average blood flow velocity in the popliteal artery. pCASL and PASL provide precise and consistent measurement of skeletal muscle reactive hyperemia perfusion dynamics. J. MAGN. RESON. IMAGING 2016;44:929-939.
PURPOSE: To compare calf skeletal muscle perfusion measured with pulsed arterial spin labeling (PASL) and pseudo-continuous arterial spin labeling (pCASL) methods, and to assess the variability of pCASL labeling efficiency in the popliteal artery throughout an ischemia-reperfusion paradigm. MATERIALS AND METHODS: At 3T, relative pCASL labeling efficiency was experimentally assessed in five subjects by measuring the signal intensity of blood in the popliteal artery just distal to the labeling plane immediately following pCASL labeling or control preparation pulses, or without any preparation pulses throughout separate ischemia-reperfusion paradigms. The relative label and control efficiencies were determined during baseline, hyperemia, and recovery. In a separate cohort of 10 subjects, pCASL and PASL sequences were used to measure reactive hyperemia perfusion dynamics. RESULTS: Calculated pCASL labeling and control efficiencies did not differ significantly between baseline and hyperemia or between hyperemia and recovery periods. Relative to the average baseline, pCASL label efficiency was 2 ± 9% lower during hyperemia. Perfusion dynamics measured with pCASL and PASL did not differ significantly (P > 0.05). Average leg muscle peak perfusion was 47 ± 20 mL/min/100g or 50 ± 12 mL/min/100g, and time to peak perfusion was 25 ± 3 seconds and 25 ± 7 seconds from pCASL and PASL data, respectively. Differences of further metrics parameterizing the perfusion time course were not significant between pCASL and PASL measurements (P > 0.05). CONCLUSION: No change in pCASL labeling efficiency was detected despite the almost 10-fold increase in average blood flow velocity in the popliteal artery. pCASL and PASL provide precise and consistent measurement of skeletal muscle reactive hyperemia perfusion dynamics. J. MAGN. RESON. IMAGING 2016;44:929-939.
Authors: Garry E Gold; Eric Han; Jeff Stainsby; Graham Wright; Jean Brittain; Christopher Beaulieu Journal: AJR Am J Roentgenol Date: 2004-08 Impact factor: 3.959
Authors: Christopher P Elder; Ryan N Cook; Kenneth L Wilkens; Marti A Chance; Otto A Sanchez; Bruce M Damon Journal: J Appl Physiol (1985) Date: 2010-12-16
Authors: Sina Aslan; Feng Xu; Peiying L Wang; Jinsoo Uh; Uma S Yezhuvath; Matthias van Osch; Hanzhang Lu Journal: Magn Reson Med Date: 2010-03 Impact factor: 4.668
Authors: Justin D Anderson; Frederick H Epstein; Craig H Meyer; Klaus D Hagspiel; Hongkun Wang; Stuart S Berr; Nancy L Harthun; Arthur Weltman; Joseph M Dimaria; Amy M West; Christopher M Kramer Journal: J Am Coll Cardiol Date: 2009-08-11 Impact factor: 24.094
Authors: Erin K Englund; Michael C Langham; Cheng Li; Zachary B Rodgers; Thomas F Floyd; Emile R Mohler; Felix W Wehrli Journal: J Cardiovasc Magn Reson Date: 2013-08-19 Impact factor: 5.364
Authors: Erin K Englund; Zachary B Rodgers; Michael C Langham; Emile R Mohler; Thomas F Floyd; Felix W Wehrli Journal: Magn Reson Med Date: 2017-05-11 Impact factor: 4.668
Authors: Jessica E Caterini; Kate Rendall; Barbara Cifra; Jane E Schneiderman; Felix Ratjen; Mike Seed; Tammy Rayner; Ruth Weiss; Brian W McCrindle; Michael D Noseworthy; Craig A Williams; Alan R Barker; Gregory D Wells Journal: Physiol Rep Date: 2022-05
Authors: Christian R Meixner; Armin M Nagel; Svenja A Höger; Lena V Gast; Marco Wiesmueller; Michael Uder; Matthias S May; Thilo Hotfiel; Rafael Heiss Journal: Quant Imaging Med Surg Date: 2022-09