The threshold limit value (TLV) guideline for ultraviolet (UV) radiation specifies that irradiance measurements to ensure occupant safety be taken over an angle of 80° at the sensor. The purpose of this study was to evaluate the effect of an 80° field of view (FOV) tube on lower room UV-C irradiation measurements. Measurements were made in an experimental chamber at a height of 1.73m with and without an FOV tube. The FOV tube reduced the lower room irradiance readings by 18-34%, a statistically significant reduction compared to the bare sensor. An 80° FOV tube should be used for lower room irradiance measurements to comply with the TLV guideline. The resulting lower readings would allow more UV-C radiation in the upper room without compromising occupant safety. More UV-C radiation in the upper room could increase efficacy of UVGI systems for reducing transmission of airborne infectious diseases. In addition, recommendations are made to standardize lower room irradiance measurement techniques.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Occupant safety measurements; Threshold limit value; Ultraviolet germicidal irradiation

Mesh:

Substances:

Year:  2016        PMID: 27038734      PMCID: PMC4854786          DOI: 10.1016/j.jphotobiol.2016.03.009

Source DB:  PubMed          Journal:  J Photochem Photobiol B        ISSN: 1011-1344            Impact factor:   6.252


  6 in total

1.  Monitoring human exposures to upper-room germicidal ultraviolet irradiation.

Authors:  Melvin W First; Robert A Weker; Shojiro Yasui; Edward A Nardell
Journal:  J Occup Environ Hyg       Date:  2005-05       Impact factor: 2.155

2.  Safety of upper-room ultraviolet germicidal air disinfection for room occupants: results from the Tuberculosis Ultraviolet Shelter Study.

Authors:  Edward A Nardell; Scott J Bucher; Philip W Brickner; Charles Wang; Richard L Vincent; Kathleen Becan-McBride; Mark A James; Max Michael; James D Wright
Journal:  Public Health Rep       Date:  2008 Jan-Feb       Impact factor: 2.792

Review 3.  Balancing the risk of eye irritation from UV-C with infection from bioaerosols.

Authors:  David Sliney
Journal:  Photochem Photobiol       Date:  2013-06-15       Impact factor: 3.421

4.  Aerosol susceptibility of influenza virus to UV-C light.

Authors:  James J McDevitt; Stephen N Rudnick; Lewis J Radonovich
Journal:  Appl Environ Microbiol       Date:  2012-01-06       Impact factor: 4.792

5.  Upper-room ultraviolet light and negative air ionization to prevent tuberculosis transmission.

Authors:  A Roderick Escombe; David A J Moore; Robert H Gilman; Marcos Navincopa; Eduardo Ticona; Bailey Mitchell; Catherine Noakes; Carlos Martínez; Patricia Sheen; Rocio Ramirez; Willi Quino; Armando Gonzalez; Jon S Friedland; Carlton A Evans
Journal:  PLoS Med       Date:  2009-03-17       Impact factor: 11.069

6.  Inactivation of poxviruses by upper-room UVC light in a simulated hospital room environment.

Authors:  James J McDevitt; Donald K Milton; Stephen N Rudnick; Melvin W First
Journal:  PLoS One       Date:  2008-09-10       Impact factor: 3.240

  6 in total
  2 in total

1.  Prototyping a low-cost residential air quality device using ultraviolet germicidal irradiation (UVGI) light.

Authors:  Mohammad Al-Rawi; Annette Lazonby; Callan Smith
Journal:  HardwareX       Date:  2021-12-16

2.  The Study of an Ultraviolet Radiation Technique for Removal of the Indoor Air Volatile Organic Compounds and Bioaerosol.

Authors:  Chao-Yun Liu; Chao-Heng Tseng; Huang-Chin Wang; Chuan-Fa Dai; Yi-Hsuan Shih
Journal:  Int J Environ Res Public Health       Date:  2019-07-17       Impact factor: 3.390

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.