Technical Note: Cortical thickness and density estimation from clinical CT using a prior thickness-density relationship.

Ludovic Humbert1, Javad Hazrati Marangalou2, Luis Miguel Del Río Barquero3, G Harry van Lenthe4, Bert van Rietbergen2.   

Abstract

PURPOSE: Cortical thickness and density are critical components in determining the strength of bony structures. Computed tomography (CT) is one possible modality for analyzing the cortex in 3D. In this paper, a model-based approach for measuring the cortical bone thickness and density from clinical CT images is proposed.
METHODS: Density variations across the cortex were modeled as a function of the cortical thickness and density, location of the cortex, density of surrounding tissues, and imaging blur. High resolution micro-CT data of cadaver proximal femurs were analyzed to determine a relationship between cortical thickness and density. This thickness-density relationship was used as prior information to be incorporated in the model to obtain accurate measurements of cortical thickness and density from clinical CT volumes. The method was validated using micro-CT scans of 23 cadaver proximal femurs. Simulated clinical CT images with different voxel sizes were generated from the micro-CT data. Cortical thickness and density were estimated from the simulated images using the proposed method and compared with measurements obtained using the micro-CT images to evaluate the effect of voxel size on the accuracy of the method. Then, 19 of the 23 specimens were imaged using a clinical CT scanner. Cortical thickness and density were estimated from the clinical CT images using the proposed method and compared with the micro-CT measurements. Finally, a case-control study including 20 patients with osteoporosis and 20 age-matched controls with normal bone density was performed to evaluate the proposed method in a clinical context.
RESULTS: Cortical thickness (density) estimation errors were 0.07 ± 0.19 mm (-18 ± 92 mg/cm(3)) using the simulated clinical CT volumes with the smallest voxel size (0.33 × 0.33 × 0.5 mm(3)), and 0.10 ± 0.24 mm (-10 ± 115 mg/cm(3)) using the volumes with the largest voxel size (1.0 × 1.0 × 3.0 mm(3)). A trend for the cortical thickness and density estimation errors to increase with voxel size was observed and was more pronounced for thin cortices. Using clinical CT data for 19 of the 23 samples, mean errors of 0.18 ± 0.24 mm for the cortical thickness and 15 ± 106 mg/cm(3) for the density were found. The case-control study showed that osteoporotic patients had a thinner cortex and a lower cortical density, with average differences of -0.8 mm and -58.6 mg/cm(3) at the proximal femur in comparison with age-matched controls (p-value < 0.001).
CONCLUSIONS: This method might be a promising approach for the quantification of cortical bone thickness and density using clinical routine imaging techniques. Future work will concentrate on investigating how this approach can improve the estimation of mechanical strength of bony structures, the prevention of fracture, and the management of osteoporosis.

Entities:  

Mesh:

Year:  2016        PMID: 27036590     DOI: 10.1118/1.4944501

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Analysis of the evolution of cortical and trabecular bone compartments in the proximal femur after spinal cord injury by 3D-DXA.

Authors:  L Gifre; L Humbert; A Muxi; L Del Rio; J Vidal; E Portell; A Monegal; N Guañabens; P Peris
Journal:  Osteoporos Int       Date:  2017-10-17       Impact factor: 4.507

2.  Effects of osteoporosis drug treatments on cortical and trabecular bone in the femur using DXA-based 3D modeling.

Authors:  R Winzenrieth; L Humbert; S Di Gregorio; E Bonel; M García; L Del Rio
Journal:  Osteoporos Int       Date:  2018-07-04       Impact factor: 4.507

3.  Measuring the thickness of vertebral endplate and shell using digital tomosynthesis.

Authors:  Yener N Yeni; Michael R Dix; Angela Xiao; Daniel J Oravec; Michael J Flynn
Journal:  Bone       Date:  2022-01-28       Impact factor: 4.398

Review 4.  Cortical Bone Mapping: Measurement and Statistical Analysis of Localised Skeletal Changes.

Authors:  Graham Treece; Andrew Gee
Journal:  Curr Osteoporos Rep       Date:  2018-10       Impact factor: 5.096

5.  Proximal Femur Responses to Sequential Therapy With Abaloparatide Followed by Alendronate in Postmenopausal Women With Osteoporosis by 3D Modeling of Hip Dual-Energy X-Ray Absorptiometry (DXA).

Authors:  Renaud Winzenrieth; Paul Kostenuik; John Boxberger; Yamei Wang; Ludovic Humbert
Journal:  JBMR Plus       Date:  2022-03-10