Literature DB >> 27035060

Maximum Standardized Uptake Value of (99m)Tc Hydroxymethylene Diphosphonate SPECT/CT for the Evaluation of Temporomandibular Joint Disorder.

Min Seok Suh1, Won Woo Lee1, Young-Kyun Kim1, Pil-Young Yun1, Sang Eun Kim1.   

Abstract

Purpose To evaluate the diagnostic accuracy of the quantitative parameter standardized uptake value (SUV) at single photon emission computed tomography (SPECT)/computed tomography (CT) for the evaluation of temporomandibular joint (TMJ) disorder (TMD). Materials and Methods This study was approved by the institutional review board, and the need for informed consent was waived. Forty-four TMJs in 22 patients with TMD (five men and 17 women; mean age ± standard deviation, 30.0 years ± 12.1) were evaluated. The patients underwent planar bone scintigraphy and SPECT/CT 3-4 hours after injection of technetium 99m hydroxymethylene diphosphonate. The planar scintigraphy parameter of relative ratio (RR) and SPECT/CT parameters mean SUV (SUVmean) and maximum SUV (SUVmax) were compared for the visual assessment of TMD on planar scintigraphy images and for the presence of TMJ arthralgia. Group comparisons, receiver operating characteristic analysis, and Pearson correlation analysis were conducted. Results SUVmax gradually increased from normal (2.82 ± 0.73) to mild or moderately abnormal (3.56 ± 0.76, P < .05) and then to severely abnormal (4.86 ± 1.25, P < .05). However, RR and SUVmean did not vary significantly according to visual grade (P > .05). On the other hand, SUVmax was significantly greater in arthralgic TMJs (4.15 ± 1.11) than in nonarthralgic TMJs (2.97 ± 0.75, P < .001), as was SUVmean (1.63 ± 0.42 vs 1.30 ± 0.31, respectively; P = .005). However, there was no significant difference in RR (3.61 ± 0.57 vs 3.76 ± 0.68, P = .45). In receiver operating characteristic curve analyses for arthralgic TMJ, SUVmax had the greatest area under the curve (area of 0.815). Conclusion SUVmax derived from bone SPECT/CT may be useful for the evaluation of TMD. (©) RSNA, 2016 Online supplemental material is available for this article.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27035060     DOI: 10.1148/radiol.2016152294

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  29 in total

Review 1.  Clinical Applications of Technetium-99m Quantitative Single-Photon Emission Computed Tomography/Computed Tomography.

Authors:  Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2019-03-15

2.  Quantification of osteoblastic activity in epiphyseal growth plates by quantitative bone SPECT/CT.

Authors:  Tomohiko Yamane; Ichiei Kuji; Akira Seto; Ichiro Matsunari
Journal:  Skeletal Radiol       Date:  2018-01-11       Impact factor: 2.199

3.  Meniscal pathologies on MRI correlate with increased bone tracer uptake in SPECT/CT.

Authors:  Jan Rechsteiner; Michael T Hirschmann; Milos Dordevic; Anna L Falkowski; Enrique A Testa; Felix Amsler; Anna Hirschmann
Journal:  Eur Radiol       Date:  2018-05-22       Impact factor: 5.315

Review 4.  KSNM 60 in General Nuclear Medicine: the Old Dream Comes True.

Authors:  Won Woo Lee; Jin-Sook Ryu
Journal:  Nucl Med Mol Imaging       Date:  2022-01-28

Review 5.  Recent Advances in Nuclear Cardiology.

Authors:  Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2016-07-13

6.  Minimum Standardized Uptake Value from Quantitative Bone Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Femoral Head Viability in Patients with Femoral Neck Fracture.

Authors:  Hyun Gee Ryoo; Won Woo Lee; Ji Young Kim; Eunjung Kong; Woo Hee Choi; Joon-Kee Yoon
Journal:  Nucl Med Mol Imaging       Date:  2019-06-22

7.  Assessment of inflammatory jaw pathologies using bone SPECT/CT maximum standardized uptake value.

Authors:  Hiroo Toshima; Ichiro Ogura
Journal:  Dentomaxillofac Radiol       Date:  2020-06-15       Impact factor: 2.419

8.  Analysis of medication-related osteonecrosis of the jaw with bone SPECT/CT: relationship between patient characteristics and maximum standardized uptake value.

Authors:  Ruri Ogawa; Ichiro Ogura
Journal:  Dentomaxillofac Radiol       Date:  2021-05-21       Impact factor: 2.419

9.  Quantitative Single-Photon Emission Computed Tomography/Computed Tomography for Evaluation of Salivary Gland Dysfunction in Sjögren's Syndrome Patients.

Authors:  Jihyun Kim; Hyunjong Lee; Hwanhee Lee; Ji-In Bang; Yeon-Koo Kang; Sungwoo Bae; Yoo Sung Song; Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2018-09-19

10.  Quantitative Single-Photon Emission Computed Tomography/Computed Tomography for Glomerular Filtration Rate Measurement.

Authors:  Yeon-Koo Kang; Sohyun Park; Min Seok Suh; Seok-Soo Byun; Dong-Wan Chae; Won Woo Lee
Journal:  Nucl Med Mol Imaging       Date:  2017-08-24
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.