The recrudescence of syphilis is leading to the development of new serological tests. The goal of this study was to compare the performance of the more recent Elecsys Syphilis assay, the Electro Chemiluminescence Immunoassay (ECLIA), with the former Architect Syphilis TP assay, the Chemiluminescent Microparticle Immunoassay (CMIA), for the detection of antibodies against Treponema pallidum in blood donors. Serum samples of 5543 voluntary blood donors were screened in parallel with two tests. All repeatedly reactive (RR) samples by one or both assays were further analysed for confirmation by immmunoblot INNO-LIA and TPHA. Of 32 RR samples by CMIA, 21 were confirmed positive; of 21 RR samples by ECLIA, 20 were confirmed positive. The sensitivities of CMIA and ECLIA were 100% and 95.24% (95% CI = 85.71-100), respectively, not significant (p > 0.05). The specificity and predictive positive value (PPV) of CMIA were 99.86% (95% CI = 99.74-99.94) and 72.41%, respectively, while the specificity and PPV of ECLIA were both 100%, being statistically significant (p = 0.01 for both). The overall agreement was 99.80% and the Cohen's kappa coefficients was 0.79. In conclusion, the recent Elecsys Syphilis assay could represent another reliable assay for blood donor screening.

Entities:  

Keywords:  CMIA; ECLIA; Syphilis assay; blood donors; serological screening

Mesh:

Substances:

Year:  2016        PMID: 27030921     DOI: 10.3109/23744235.2016.1142674

Source DB:  PubMed          Journal:  Infect Dis (Lond)        ISSN: 2374-4243


  2 in total

Review 1.  Occult Hepatitis Infection in Transfusion Medicine: Screening Policy and Assessment of Current Use of Anti-HBc Testing.

Authors:  Antonella Esposito; Chiara Sabia; Carmela Iannone; Giovanni F Nicoletti; Linda Sommese; Claudio Napoli
Journal:  Transfus Med Hemother       Date:  2017-05-05       Impact factor: 3.747

2.  Evaluate performance of the Abbott chemiluminescent microparticle immunoassay assay for detection of syphilis infection in Chinese blood donors.

Authors:  Ping Fu; Sushil Devare; Jian-Fang Liu; Xiao-Ting Lv; Peng Yin; Bing-Ting Wu; Ling Ke; Yu Liu; Hua Shan
Journal:  J Clin Lab Anal       Date:  2019-10-16       Impact factor: 2.352

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.