Literature DB >> 27027625

Corneal Power Measurement With the Dual Scheimpflug-Placido Topographer After Myopic Excimer Laser Surgery.

Chao Pan, Yanjun Hua, Jinhai Huang, Weina Tan, Weicong Lu, Qinmei Wang.   

Abstract

PURPOSE: To evaluate the ability of the Sirius Scheimpflug-Placido Topographer (Costruzione Strumenti Oftalmici, Florence, Italy) in predicting corneal power in eyes with previous myopic corneal refractive surgery.
METHODS: The following corneal refractive power measurements were obtained with Sirius in 38 eyes with prior myopic excimer laser surgery: simulated keratometry (SimK), true net power based on the Gaussian optical formula (TNP), and the mean pupil power (MPP) calculated by ray tracing within the diameter of the entrance pupil range from 2.5 to 6 mm. These values, along with the corresponding keratometric value, which was based on the equation that converted the MPP within 4.5-mm entrance pupil diameter to a keratometric reading in 75 myopic eyes, were compared using the clinical history method.
RESULTS: SimK significantly overestimated corneal power by 0.67 ± 0.52 diopters (D), whereas TNP significantly underestimated corneal power by -1.05 ± 0.48 D. The only measurements that showed no statistically significant difference by the clinical history method were the 5 mm MPP, 5.5 mm MPP, and KMPP4.5POST, and the 95% limits of agreement (LOA) were -1.10 to 0.62, -0.91 to 0.89, and -0.67 to 1.05 D, respectively.
CONCLUSIONS: The Sirius Scheimpflug-Placido Topographer is an alternative method of measuring corneal power in eyes with previous corneal refractive surgery for myopia when preoperative data are not available. The best options seem to be the 5 mm MPP, 5.5 mm MPP, and the keratometric reading calculated from the regression formula. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27027625     DOI: 10.3928/1081597X-20160106-02

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  4 in total

1.  Corneal power measurement with a new aberrometer/corneal topographer in eyes after small incision lenticule extraction for myopia.

Authors:  Chao Pan; Weina Tan; Yanjun Hua; Xiaohua Lei
Journal:  Int Ophthalmol       Date:  2019-05-27       Impact factor: 2.031

2.  A novel analysis of Scheimpflug total corneal refractive power following corneal cross-linking in mild to moderate keratoconus.

Authors:  Chao Pan; Wei-Na Tan; Dan Chen; Yu Liu; Hao-Yu Wang; Deng-Feng Liang; Yan-Jun Hua; Xiao-Hua Lei; Qing-Yan Zeng; Shao-Zhen Zhao
Journal:  Int J Ophthalmol       Date:  2022-05-18       Impact factor: 1.779

3.  Comprehensive evaluation of total corneal refractive power by ray tracing in predicting corneal power in eyes after small incision lenticule extraction.

Authors:  Chao Pan; Weina Tan; Yanjun Hua; Xiaohua Lei
Journal:  PLoS One       Date:  2019-06-06       Impact factor: 3.240

4.  Corneal power changes with Scheimpflug rotating camera after hyperopic LASIK.

Authors:  Woong-Joo Whang; Young-Sik Yoo; Choun-Ki Joo
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

  4 in total