Literature DB >> 27025165

Can surface imaging improve the patient setup for proton postmastectomy chest wall irradiation?

Estelle Batin1, Nicolas Depauw2, Shannon MacDonald2, Hsiao-Ming Lu2.   

Abstract

PURPOSES/
OBJECTIVES: For postmastectomy radiation therapy by proton beams, the usual bony landmark based radiograph setup technique is indirect because the target volumes are generally superficial and far away from major bony structures. The surface imaging setup technique of matching chest wall surface directly to treatment planning computed tomography was evaluated and compared to the traditional radiograph-based technique. METHODS AND MATERIALS: Fifteen postmastectomy radiation therapy patients were included, with the first 5 patients positioned by standard radiograph-based technique; radiopaque makers, however, were added on the patient's skin surface to improve the relevance of the setup. AlignRT was used to capture patient surface images at different time points along the process, with the calculated position corrections recorded but not applied. For the remaining 10 patients, the orthogonal x-ray imaging was replaced by the AlignRT setup procedure followed by a beamline radiograph at the treatment gantry angle only as confirmation. The position corrections recorded during all fractions for all patients (28-31 each) were analyzed to evaluate the setup accuracy. The time spent on patient setup and treatment delivery was also analyzed.
RESULTS: The average position discrepancy over the treatment course relative to the planning computed tomography was significantly larger in the radiograph only group, particularly in translations (3.2 ± 2.0 mm in vertical, 3.1 ± 3.0 mm in longitudinal, 2.6 ± 2.5 mm in lateral), than AlignRT assisted group (1.3 ± 1.3 mm in vertical, 0.8 ± 1.2 mm in longitudinal, 1.5 ± 1.4 mm in lateral). The latter was well within the robustness limits (±3 mm) of the pencil beam scanning treatment established in our previous studies. The setup time decreased from an average of 11 minutes using orthogonal x-rays to an average of 6 minutes using AlignRT surface imaging.
CONCLUSIONS: The use of surface imaging allows postmastectomy chest wall patients to be positioned more accurately and substantially more efficiently than radiograph only-based techniques.
Copyright © 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27025165     DOI: 10.1016/j.prro.2016.02.001

Source DB:  PubMed          Journal:  Pract Radiat Oncol        ISSN: 1879-8500


  12 in total

1.  A Technical Guide for Passive Scattering Proton Radiation Therapy for Breast Cancer.

Authors:  Julie A Bradley; Meng Wei Ho; Zuofeng Li; Xiaoying Liang; Michael Rutenberg; Roi Dagan; Nancy P Mendenhall
Journal:  Int J Part Ther       Date:  2017-07-11

2.  Impact of surface-guided positioning on the use of portal imaging and initial set-up duration in breast cancer patients.

Authors:  Montserrat Pazos; Franziska Walter; Daniel Reitz; Stephan Schönecker; Dinah Konnerth; Annemarie Schäfer; Maya Rottler; Filippo Alongi; Philipp Freislederer; Maximilian Niyazi; Claus Belka; Stefanie Corradini
Journal:  Strahlenther Onkol       Date:  2019-07-22       Impact factor: 3.621

3.  Dosimetric consequences of image guidance techniques on robust optimized intensity-modulated proton therapy for treatment of breast Cancer.

Authors:  Xiaoying Liang; Raymond B Mailhot Vega; Zuofeng Li; Dandan Zheng; Nancy Mendenhall; Julie A Bradley
Journal:  Radiat Oncol       Date:  2020-02-27       Impact factor: 3.481

4.  Arms positioning in post-mastectomy proton radiation: Feasibility and development of a new arms down contouring atlas.

Authors:  Nicolas Depauw; Estelle Batin; Andrew Johnson; Shannon M MacDonald; Rachel B Jimenez
Journal:  Phys Imaging Radiat Oncol       Date:  2020-05-26

Review 5.  Particle Therapy for Breast Cancer.

Authors:  Roman O Kowalchuk; Kimberly S Corbin; Rachel B Jimenez
Journal:  Cancers (Basel)       Date:  2022-02-20       Impact factor: 6.639

6.  Surface guided radiation therapy: An international survey on current clinical practice.

Authors:  V Batista; M Gober; F Moura; A Webster; M Oellers; M Ramtohul; M Kügele; P Freislederer; M Buschmann; G Anastasi; E Steiner; H Al-Hallaq; J Lehmann
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-03-30

7.  Feasibility of surface guided radiotherapy for patient positioning in breast radiotherapy versus conventional tattoo-based setups- a systematic review.

Authors:  Wesley Naidoo; Michelle Leech
Journal:  Tech Innov Patient Support Radiat Oncol       Date:  2022-04-16

8.  Setup errors and effectiveness of Optical Laser 3D Surface imaging system (Sentinel) in postoperative radiotherapy of breast cancer.

Authors:  Xiaobo Wei; Mengjiao Liu; Yun Ding; Qilin Li; Changhai Cheng; Xian Zong; Wenming Yin; Jie Chen; Wendong Gu
Journal:  Sci Rep       Date:  2018-05-08       Impact factor: 4.379

Review 9.  Recent advanced in Surface Guided Radiation Therapy.

Authors:  P Freislederer; M Kügele; M Öllers; A Swinnen; T-O Sauer; C Bert; D Giantsoudi; S Corradini; V Batista
Journal:  Radiat Oncol       Date:  2020-07-31       Impact factor: 3.481

10.  Impact of use of optical surface imaging on initial patient setup for stereotactic body radiotherapy treatments.

Authors:  Brian Leong; Laura Padilla
Journal:  J Appl Clin Med Phys       Date:  2019-12       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.