Literature DB >> 27019800

Standardization in laboratory medicine: Adoption of common reference intervals to the Croatian population.

Zlata Flegar-Meštrić1, Sonja Perkov1, Andrea Radeljak1.   

Abstract

Considering the fact that the results of laboratory tests provide useful information about the state of health of patients, determination of reference value is considered an intrinsic part in the development of laboratory medicine. There are still huge differences in the analytical methods used as well as in the associated reference intervals which could consequently significantly affect the proper assessment of patient health. In a constant effort to increase the quality of patients' care, there are numerous international initiatives for standardization and/or harmonization of laboratory diagnostics in order to achieve maximum comparability of laboratory test results and improve patient safety. Through the standardization and harmonization processes of analytical methods the ability to create unique reference intervals is achieved. Such reference intervals could be applied globally in all laboratories using methods traceable to the same reference measuring system and analysing the biological samples from the populations with similar socio-demographic and ethnic characteristics. In this review we outlined the results of the harmonization processes in Croatia in the field of population based reference intervals for clinically relevant blood and serum constituents which are in accordance with ongoing activity for worldwide standardization and harmonization based on traceability in laboratory medicine.

Entities:  

Keywords:  Aminotransferase “common” reference intervals; Applicability of reference intervals; Calibration traceability; Creatinine enzymatic method; External quality assessment; Harmonization and standardisation; International Federation of Clinical Chemistry enzyme reference methods

Year:  2016        PMID: 27019800      PMCID: PMC4804256          DOI: 10.5662/wjm.v6.i1.93

Source DB:  PubMed          Journal:  World J Methodol        ISSN: 2222-0682


  32 in total

1.  Current databases on biological variation: pros, cons and progress.

Authors:  C Ricós; V Alvarez; F Cava; J V García-Lario; A Hernández; C V Jiménez; J Minchinela; C Perich; M Simón
Journal:  Scand J Clin Lab Invest       Date:  1999-11       Impact factor: 1.713

Review 2.  Reference intervals: an update.

Authors:  Paul S Horn; Amadeo J Pesce
Journal:  Clin Chim Acta       Date:  2003-08       Impact factor: 3.786

3.  The Nordic Reference Interval Project 2000: recommended reference intervals for 25 common biochemical properties.

Authors:  P Rustad; P Felding; L Franzson; V Kairisto; A Lahti; A Mårtensson; P Hyltoft Petersen; P Simonsson; H Steensland; A Uldall
Journal:  Scand J Clin Lab Invest       Date:  2004       Impact factor: 1.713

4.  A "Step-Up" approach for harmonization.

Authors:  Katleen Van Uytfanghe; Linde A De Grande; Linda M Thienpont
Journal:  Clin Chim Acta       Date:  2013-12-18       Impact factor: 3.786

5.  Verification of in vitro medical diagnostics (IVD) metrological traceability: responsibilities and strategies.

Authors:  Federica Braga; Mauro Panteghini
Journal:  Clin Chim Acta       Date:  2013-12-01       Impact factor: 3.786

6.  Pediatric reference intervals for 34 biochemical analytes in urban school children and adolescents.

Authors:  N Jagarinec; Z Flegar-Mestrić; B Surina; D Vrhovski-Hebrang; V Preden-Kereković
Journal:  Clin Chem Lab Med       Date:  1998-05       Impact factor: 3.694

7.  Application of the stockholm hierarchy to defining the quality of reference intervals and clinical decision limits.

Authors:  Ken Sikaris
Journal:  Clin Biochem Rev       Date:  2012-11

8.  Closing the gaps in pediatric laboratory reference intervals: a CALIPER database of 40 biochemical markers in a healthy and multiethnic population of children.

Authors:  David A Colantonio; Lianna Kyriakopoulou; Man Khun Chan; Caitlin H Daly; Davor Brinc; Allison A Venner; Maria D Pasic; David Armbruster; Khosrow Adeli
Journal:  Clin Chem       Date:  2012-02-27       Impact factor: 8.327

9.  The importance of standardization of creatinine in the implementation of guidelines and recommendations for CKD: implications for CKD management programmes.

Authors:  Wim Van Biesen; Raymond Vanholder; Nic Veys; Francis Verbeke; Joris Delanghe; Dirk De Bacquer; Norbert Lameire
Journal:  Nephrol Dial Transplant       Date:  2005-10-12       Impact factor: 5.992

10.  Applicability of common reference intervals for serum creatinine concentrations to the Croatian population.

Authors:  Zlata Flegar-Mestrić; Sonja Perkov; Barbara Simonović; Dubravka Juretić
Journal:  Clin Chem Lab Med       Date:  2010-02       Impact factor: 3.694

View more
  2 in total

1.  Key Performance Indicators to Measure Improvement After Implementation of Total Laboratory Automation Abbott Accelerator a3600.

Authors:  Marijana Miler; Nora Nikolac Gabaj; Lora Dukic; Ana-Maria Simundic
Journal:  J Med Syst       Date:  2017-12-27       Impact factor: 4.460

2.  Indirect determination of biochemistry reference intervals using outpatient data.

Authors:  Luisa Martinez-Sanchez; Christa M Cobbaert; Raymond Noordam; Nannette Brouwer; Albert Blanco-Grau; Yolanda Villena-Ortiz; Marc Thelen; Roser Ferrer-Costa; Ernesto Casis; Francisco Rodríguez-Frias; Wendy P J den Elzen
Journal:  PLoS One       Date:  2022-05-19       Impact factor: 3.752

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.