Literature DB >> 27016912

Development of a label-free SPR sensor for detection of matrixmetalloproteinase-9 by antibody immobilization on carboxymethyldextran chip.

Sara Mohseni1, Tahereh Tohidi Moghadam1, Bahareh Dabirmanesh2, Safoura Jabbari2, Khosro Khajeh3.   

Abstract

Surface plasmon resonance (SPR) immunosensor has been widely utilized for monitoring antigen-antibody interactions. The sensor measures changes of refractive index upon binding of analyte molecules to specific ligand immobilized on the sensor chip. This effort reports development of SPR immunosensor for real-time and label-free detection of recombinant human matrix metalloproteinases-9 (MMP-9), which has been associated with malignant tumor progression and metastasis by matrix degradation. MMP-9 was expressed in Escherichia coli BL21 and purified by Ni-NTA agarose column. CMD 50 D was activated by EDC/NHS for immobilization of monoclonal anti-MMP-9. Atomic force microscopy images showed uniform distribution of anti-MMP-9 over the sensor chip. Equilibrium constant (KD), maximum binding capacity (Rmax) and ∆Gb values for interaction of MMP-9 and anti-MMP-9 were 0.4nM, 680 µRIU and -53.51kJ/mol, respectively. Concentration of MMP-9 in saliva samples was determined, with linearity in the range of 10-200ng/mL. The limit of detection was found to be 8pg/mL, being lower than most of the previously reported techniques.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chronic periodontitis; Matrixmetalloproteinase-9; Refractive index; Sensor chip; Surface plasmon resonance

Mesh:

Substances:

Year:  2016        PMID: 27016912     DOI: 10.1016/j.bios.2016.03.038

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Surface Plasmon Resonance Immunosensor with Antibody-Functionalized Magnetoplasmonic Nanoparticles for Ultrasensitive Quantification of the CD5 Biomarker.

Authors:  Asta Kausaite-Minkstimiene; Anton Popov; Almira Ramanaviciene
Journal:  ACS Appl Mater Interfaces       Date:  2022-05-02       Impact factor: 10.383

2.  Assembly of Gold Nanorods on HSA Amyloid Fibrils to Develop a Conductive Nanoscaffold for Potential Biomedical and Biosensing Applications.

Authors:  Ramezan Ali Taheri; Yasin Akhtari; Tahereh Tohidi Moghadam; Bijan Ranjbar
Journal:  Sci Rep       Date:  2018-06-19       Impact factor: 4.379

Review 3.  Matrix Metalloproteinase-9 (MMP-9) as a Cancer Biomarker and MMP-9 Biosensors: Recent Advances.

Authors:  Hao Huang
Journal:  Sensors (Basel)       Date:  2018-09-27       Impact factor: 3.576

Review 4.  Emergent Biosensing Technologies Based on Fluorescence Spectroscopy and Surface Plasmon Resonance.

Authors:  Alessandra Camarca; Antonio Varriale; Alessandro Capo; Angela Pennacchio; Alessia Calabrese; Cristina Giannattasio; Carlos Murillo Almuzara; Sabato D'Auria; Maria Staiano
Journal:  Sensors (Basel)       Date:  2021-01-29       Impact factor: 3.576

Review 5.  Bioanalytical methods for circulating extracellular matrix-related proteins: new opportunities in cancer diagnosis.

Authors:  Ramón Lorenzo-Gómez; Rebeca Miranda-Castro; Noemí de-Los-Santos-Álvarez; María Jesús Lobo-Castañón
Journal:  Anal Bioanal Chem       Date:  2021-06-05       Impact factor: 4.142

Review 6.  Low-Fouling Substrates for Plasmonic Sensing of Circulating Biomarkers in Biological Fluids.

Authors:  Elba Mauriz
Journal:  Biosensors (Basel)       Date:  2020-06-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.