Literature DB >> 27014425

Use of automated irrigation pumps improves quality of bowel preparation for colonoscopy.

Sujan Ravi1, Rana Sabbagh1, Fadi Antaki1.   

Abstract

AIM: To evaluate the effectiveness of automated irrigation pumps (AIPs) in improving the quality of the bowel preparation and the yield of colonoscopy.
METHODS: A retrospective observational study was conducted at a single medical center. Outpatient colonoscopies performed during a 4-mo time period when AIPs were not in use, were compared to colonoscopies performed during control period. The main outcomes measured were quality of bowel preparation, procedures aborted due to poor preparation, recommendations to repeat at short interval due to sub-optimal bowel preparation and adenoma detection rates.
RESULTS: One thousand and thirty-seven colonoscopies were included. A higher proportion of cases did not achieve a satisfactory bowel preparation when AIPs were not used (24.4% vs 10.3%, P < 0.01). The number of procedures aborted due to inadequate preparation was not significantly different, however a repeat procedure at a short interval was recommended in a higher proportion of cases when AIPs were not used (21.3% vs 6.9%, P < 0.01). Good or excellent preparation was 2.91 (95%CI: 2.04-4.15) times more likely when AIPs were used. Detection of polyps and adenomas was not significantly different.
CONCLUSION: AIP use during colonoscopy results in a higher proportion of colonic preparation rated as satisfactory, although polyp detection rate is not significantly affected. Recommendations for repeat colonoscopy at shorter interval significantly decrease with the use of AIPs. This study supports the use of the irrigation pumps in endoscopy units to improve the quality of colonoscopy.

Entities:  

Keywords:  Adenoma; Automated irrigation pumps; Bowel preparation; Colonoscopy; Polyps; Quality; Surveillance interval

Year:  2016        PMID: 27014425      PMCID: PMC4804187          DOI: 10.4253/wjge.v8.i6.295

Source DB:  PubMed          Journal:  World J Gastrointest Endosc


  19 in total

1.  The impact of colon cleanliness assessment on endoscopists' recommendations for follow-up colonoscopy.

Authors:  Shomron Ben-Horin; Simon Bar-Meir; Benjamin Avidan
Journal:  Am J Gastroenterol       Date:  2007-08-21       Impact factor: 10.864

2.  Prevalence of missed adenomas in patients with inadequate bowel preparation on screening colonoscopy.

Authors:  Reena V Chokshi; Christine E Hovis; Thomas Hollander; Dayna S Early; Jean S Wang
Journal:  Gastrointest Endosc       Date:  2012-02-28       Impact factor: 9.427

Review 3.  Colorectal cancer screening: health impact and cost effectiveness.

Authors:  Michael V Maciosek; Leif I Solberg; Ashley B Coffield; Nichol M Edwards; Michael J Goodman
Journal:  Am J Prev Med       Date:  2006-07       Impact factor: 5.043

4.  The effect of colonoscopy preparation quality on adenoma detection rates.

Authors:  Eric A Sherer; Timothy D Imler; Thomas F Imperiale
Journal:  Gastrointest Endosc       Date:  2011-12-03       Impact factor: 9.427

5.  Association of colonoscopy and death from colorectal cancer.

Authors:  Nancy N Baxter; Meredith A Goldwasser; Lawrence F Paszat; Refik Saskin; David R Urbach; Linda Rabeneck
Journal:  Ann Intern Med       Date:  2008-12-15       Impact factor: 25.391

6.  Impact of colonic cleansing on quality and diagnostic yield of colonoscopy: the European Panel of Appropriateness of Gastrointestinal Endoscopy European multicenter study.

Authors:  Florian Froehlich; Vincent Wietlisbach; Jean-Jacques Gonvers; Bernard Burnand; John-Paul Vader
Journal:  Gastrointest Endosc       Date:  2005-03       Impact factor: 9.427

7.  Screening colonoscopy for colorectal cancer prevention: results from a German online registry on 269000 cases.

Authors:  Bernd Bokemeyer; Herbert Bock; Dietrich Hüppe; Marc Düffelmeyer; Axel Rambow; Wolfgang Tacke; Herbert Koop
Journal:  Eur J Gastroenterol Hepatol       Date:  2009-06       Impact factor: 2.566

8.  Are physicians doing too much colonoscopy? A national survey of colorectal surveillance after polypectomy.

Authors:  Pauline A Mysliwiec; Martin L Brown; Carrie N Klabunde; David F Ransohoff
Journal:  Ann Intern Med       Date:  2004-08-17       Impact factor: 25.391

9.  Effectiveness of a simplified "patient friendly" split dose polyethylene glycol colonoscopy prep in Veterans Health Administration patients.

Authors:  Benjamin Cohen; Raymond S Tang; Erik Groessl; Ann Herrin; Samuel B Ho
Journal:  J Interv Gastroenterol       Date:  2012-10-01

10.  The impact of fair colonoscopy preparation on colonoscopy use and adenoma miss rates in patients undergoing outpatient colonoscopy.

Authors:  Stacy B Menees; H Myra Kim; Eric E Elliott; Jennifer L Mickevicius; Brittany B Graustein; Philip S Schoenfeld
Journal:  Gastrointest Endosc       Date:  2013-04-30       Impact factor: 9.427

View more