Literature DB >> 27007131

A comparison of electrothermal bipolar vessel sealing system and electrocautery in selective neck dissection.

Kerem Ozturk1, Isa Kaya1, Goksel Turhal2, Arin Ozturk1, Gulce Gursan3, Serdar Akyildiz1.   

Abstract

The use of LigaSure™ vessel sealing system in head and neck surgery was reported to be reliable and safe, providing sufficient hemostasis and reducing operating time. The aim of this study was to evaluate efficacy of this technique in patients undergoing selective neck dissections. This study was carried out as a prospective controlled study at an otolaryngology department of a tertiary medical center between July 2013 and July 2015. Twenty-five patients older than 18 years who underwent unilateral selective neck dissection for head and neck cancer were included in the study. In the control group (group 2, 10 patients) only monopolar and bipolar diathermy was used; in the Ligasure group (group 1, 15 patients) Ligasure was used for hemostasis and dissection in addition to the conventional techniques. Cervical lymphadenectomy time, operation time, preoperative hemoglobin levels, preoperative hematocrit levels, postoperative hemoglobin levels, postoperative hematocrit levels, total neck drainage and drain removal time were analyzed and compared between the groups. Median operation time in group 1 and 2 were 95 min (IQR = 35) and 142.5 min (IQR = 63), respectively. Median cervical lymphadenectomy time in group 1 and 2 were 55 min (IQR = 23) and 102.5 min (IQR = 49), respectively. Median operation time and cervical operation time were significantly lower in group 1 (p < 0.05). In conclusion, LigaSure™ vessel sealing system is a safe, efficacious technique and significantly lowers cervical lymphadenectomy and operation time in selective neck dissections compared to controls. Given the superb hemostatic properties, this technique should be in the surgeon's armamentarium when possible.

Entities:  

Keywords:  Bipolar diathermy; Electrocautery; Ligasure; Neck dissection; Vessel sealing

Mesh:

Year:  2016        PMID: 27007131     DOI: 10.1007/s00405-016-3999-0

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  19 in total

1.  Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery.

Authors:  J Dubuc-Lissoir
Journal:  Surg Endosc       Date:  2002-10-31       Impact factor: 4.584

Review 2.  The use of the Ligasure vessel sealing system in head and neck surgery: a report on six years of experience and a review of the literature.

Authors:  E P Prokopakis; V A Lachanas; A S Vardouniotis; G A Velegrakis
Journal:  B-ENT       Date:  2010       Impact factor: 0.082

3.  The use of Ligasure Vessel Sealing System in thyroid surgery.

Authors:  Vassilios A Lachanas; Emmanuel P Prokopakis; Antonios A Mpenakis; Alexander D Karatzanis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-03       Impact factor: 3.497

4.  The use of the Ligasure Vessel Sealing System in parotid gland surgery.

Authors:  Emmanuel P Prokopakis; Vassilios A Lachanas; Emmanuel S Helidonis; George A Velegrakis
Journal:  Otolaryngol Head Neck Surg       Date:  2005-11       Impact factor: 3.497

5.  How we do it: application of Ligasure Vessel Sealing System in patients undergoing total laryngectomy and radical neck dissection.

Authors:  E P Prokopakis; V A Lachanas; A D Karatzanis; A A Benakis; G A Velegrakis
Journal:  Clin Otolaryngol       Date:  2005-04       Impact factor: 2.597

6.  Tonsillectomy using the Ligasure vessel sealing system. A preliminary report.

Authors:  Emmanuel P Prokopakis; Vassilios A Lachanas; Antonios A Benakis; Emmanuel S Helidonis; George A Velegrakis
Journal:  Int J Pediatr Otorhinolaryngol       Date:  2005-09       Impact factor: 1.675

7.  A comparison of the outcome using Ligasure™ small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study.

Authors:  S Coiro; F M Frattaroli; F De Lucia; E Manna; F Fabi; J M Frattaroli; G Pappalardo
Journal:  Langenbecks Arch Surg       Date:  2015-01-13       Impact factor: 3.445

8.  High-burst-strength, feedback-controlled bipolar vessel sealing.

Authors:  J S Kennedy; P L Stranahan; K D Taylor; J G Chandler
Journal:  Surg Endosc       Date:  1998-06       Impact factor: 4.584

9.  Laparoscopic nephrectomy using Ligasure system: preliminary experience.

Authors:  Costantino Leonardo; Salvatore Guaglianone; Piero De Carli; Vincenzo Pompeo; Ester Forastiere; Michele Gallucci
Journal:  J Endourol       Date:  2005-10       Impact factor: 2.942

10.  Energy sources for laparoscopic colectomy: a prospective randomized comparison of conventional electrosurgery, bipolar computer-controlled electrosurgery and ultrasonic dissection. Operative outcome and costs analysis.

Authors:  Eduardo Ma Targarona; Carmen Balague; Juan Marin; Rene Berindoague Neto; Carmen Martinez; Jordi Garriga; Manuel Trias
Journal:  Surg Innov       Date:  2005-12       Impact factor: 2.058

View more
  6 in total

1.  Detection of the Lateral Thermal Spread during Bipolar Vessel Sealing in an Ex Vivo Model-Preliminary Results.

Authors:  Andreas Kirschbaum; Jan Jonas; Thomas M Surowiec; Anika Pehl; Nikolas Mirow
Journal:  Diagnostics (Basel)       Date:  2022-05-12

2.  In silico evaluation of geometry variations with respect to the thermal spread during coagulation of egg white using bipolar vessel sealing instruments.

Authors:  Jay Wagenpfeil; Christina Schöllig; Volker Mayer; Ronny Feuer; Bernhard Nold; Alexander Neugebauer; Michael Ederer; Ralf Rothmund; Bernhard Krämer; Sara Brucker; Markus Enderle; Oliver Sawodny; Julia Rex
Journal:  Biomed Eng Online       Date:  2016-11-02       Impact factor: 2.819

3.  Scalpel can achieve better clinical outcomes compared with electric cautery in primary total knee arthroplasty: a comparison study.

Authors:  Wei Lin; Yike Dai; Jinghui Niu; Guangmin Yang; Ming Li; Fei Wang
Journal:  BMC Musculoskelet Disord       Date:  2020-06-29       Impact factor: 2.362

4.  LigaSure small jaw versus conventional neck dissection: a systematic review and meta-analysis.

Authors:  Tai-Yu Chen; Li-Jen Hsin; Wan-Ni Lin; Ming-Shao Tsai; Yao-Te Tsai; Yi-Chan Lee
Journal:  J Otolaryngol Head Neck Surg       Date:  2021-03-29

5.  Bipolar Vessel Sealing System Versus Suture Ligation in Selective Neck Dissection.

Authors:  Niranjan Mishra; Dipti Samal; Indu Bhusan Kar; Gaurav Sharma; Shadab Ali Baig; Rosalin Kar; Krishna Gopal Birmiwal; Gyana Ranjan Sahu
Journal:  J Maxillofac Oral Surg       Date:  2017-12-11

6.  Comparing Two Approaches for Thyroidectomy: A Health Technology Assessment through DMAIC Cycle.

Authors:  Carlo Ricciardi; Adelmo Gubitosi; Donatella Vecchione; Giuseppe Cesarelli; Francesco De Nola; Roberto Ruggiero; Ludovico Docimo; Giovanni Improta
Journal:  Healthcare (Basel)       Date:  2022-01-08
  6 in total