Literature DB >> 27004629

Effects of an auditory biofeedback device on plantar pressure in patients with chronic ankle instability.

Luke Donovan1, Mark A Feger2, Joseph M Hart3, Susan Saliba4, Joseph Park5, Jay Hertel6.   

Abstract

Chronic ankle instability (CAI) patients have been shown to have increased lateral column plantar pressure throughout the stance phase of gait. To date, traditional CAI rehabilitation programs have been unable to alter gait. We developed an auditory biofeedback device that can be worn in shoes that elicits an audible cue when an excessive amount of pressure is applied to a sensor. This study determined whether using this device can decrease lateral plantar pressure in participants with CAI and alter surface electromyography (sEMG) amplitudes (anterior tibialis, peroneus longus, medial gastrocnemius, and gluteus medius). Ten CAI patients completed baseline treadmill walking while in-shoe plantar pressures and sEMG were measured (baseline condition). Next, the device was placed into the shoe and set to a threshold that would elicit an audible cue during each step of the participant's normal gait. Then, participants were instructed to walk in a manner that would not trigger the audible cue, while plantar pressure and sEMG measures were recorded (auditory feedback (AUD FB) condition). Compared to baseline, there was a statistically significant reduction in peak pressure in the lateral midfoot-forefoot and central forefoot during the AUD FB condition. In addition, there were increases in peroneus longus and medial gastrocnemius sEMG amplitudes 200 ms post-initial contact during the AUD FB condition. The use of this auditory biofeedback device resulted in decreased plantar pressure in the lateral column of the foot during treadmill walking in CAI patients and may have been caused by the increase in sEMG activation of the peroneus longus.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Gait retraining; Rehabilitation; Surface electromyography

Mesh:

Year:  2015        PMID: 27004629     DOI: 10.1016/j.gaitpost.2015.10.013

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  3 in total

1.  Embodiment of a virtual prosthesis through training using an EMG-based human-machine interface: Case series.

Authors:  Karina Aparecida Rodrigues; João Vitor da Silva Moreira; Daniel José Lins Leal Pinheiro; Rodrigo Lantyer Marques Dantas; Thaís Cardoso Santos; João Luiz Vieira Nepomuceno; Maria Angélica Ratier Jajah Nogueira; Esper Abrão Cavalheiro; Jean Faber
Journal:  Front Hum Neurosci       Date:  2022-08-04       Impact factor: 3.473

2.  Biomechanical Response to External Biofeedback During Functional Tasks in Individuals With Chronic Ankle Instability.

Authors:  Danielle M Torp; Abbey C Thomas; Tricia Hubbard-Turner; Luke Donovan
Journal:  J Athl Train       Date:  2021-03-01       Impact factor: 2.860

3.  The Effects of Insole-Based Visual Feedback on Weight-Bearing in Patients Undergoing Total Hip Replacement.

Authors:  Luca Marin; Matteo Vandoni; Giancarlo Zaza; Massimiliano Febbi; Luisella Pedrotti; Matteo Chiodaroli; Nicola Lovecchio; Federica Manzoni
Journal:  Int J Environ Res Public Health       Date:  2021-03-24       Impact factor: 3.390

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.