Literature DB >> 27004292

Marginal Bone Response Around Immediate- and Delayed-Loading Implants Supporting a Locator-Retained Mandibular Overdenture: A Randomized Controlled Study.

Gian Pietro Schincaglia, Satoko Rubin, Sejal Thacker, Ajay Dhingra, Leonardo Trombelli, Effie Ioannidou.   

Abstract

PURPOSE: Implant-supported mandibular overdentures (OVDs) have been proposed as the gold standard for the treatment of edentulous mandibles. There is limited evidence on the clinical outcomes of immediate loading of two unsplinted implants supporting a mandibular OVD. The purpose of this randomized controlled trial was to evaluate the performance of two unsplinted implants supporting a Locator-retained mandibular OVD over 12 months loaded immediately or after a delay.
MATERIALS AND METHODS: Each patient received two implants 4.0 mm in diameter and 8 to 15 mm long. Locator-retained mandibular OVDs were connected to the implants either immediately (IL) or 3 months postsurgery (DL). The primary response variable was radiographic bone loss (RBL) at 6 and 12 months postsurgery. Implant length, insertion torque, implant failure, prevalence of maintenance visits, and prosthetic complications were also recorded.
RESULTS: Thirty participants (15 in the IL and 15 in the DL groups) were evaluated at 12 months. The implant cumulative survival rates were 100% and 93% for DL and IL, respectively. The mean RBL from baseline to 1 year was 0.54 (± 0.5) mm and 0.25 (± 0.5) mm for DL and IL, respectively. A statistically significant difference was observed at 12 months, with less RBL in the IL group. Insertion torque and implant length were not correlated with RBL. Also, no difference in frequency of maintenance visits and prosthetic complications was reported between the groups.
CONCLUSION: Immediate loading of two unsplinted implants supporting a Locator-retained mandibular OVD seems to be a suitable treatment option. Significantly less RBL was observed after 1 year of loading around IL implants than around DL implants. Furthermore, neither implant length nor insertion torque seemed to affect RBL 1 year after surgical placement.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27004292     DOI: 10.11607/jomi.4118

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

Review 1.  Unsplinted Attachments and Patient-Reported Outcome Measures (PROMs) in 2-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Pravinkumar G Patil; Liang Lin Seow; Ting Jing Kweh; Smita Nimbalkar
Journal:  Int J Dent       Date:  2022-05-24

2.  Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.

Authors:  Fernanda Faot; Amália Machado Bielemann; Alessandra Julie Schuster; Raissa Micaella Marcello-Machado; Altair Antoninha Del Bel Cury; Gustavo G Nascimento; Otacílio Luiz Chagas-Junior
Journal:  Biomed Res Int       Date:  2019-06-02       Impact factor: 3.411

Review 3.  Comparison of immediate and conventional loading protocols with respect to marginal bone loss around implants supporting mandibular overdentures: A systematic review and meta-analysis.

Authors:  Minoru Sanda; Kenji Fueki; Pranjal Radke Bari; Kazuyoshi Baba
Journal:  Jpn Dent Sci Rev       Date:  2018-10-24

Review 4.  Marginal bone loss 1 year after implantation: a systematic review for fixed and removable restorations.

Authors:  Jennifer Zimmermann; Melanie Sommer; Leticia Grize; Stefan Stubinger
Journal:  Clin Cosmet Investig Dent       Date:  2019-07-16

5.  Effects of immediate and delayed loading protocols on marginal bone loss around implants in unsplinted mandibular implant-retained overdentures: a systematic review and meta-analysis.

Authors:  Wei Liu; He Cai; Junjiang Zhang; Jian Wang; Lei Sui
Journal:  BMC Oral Health       Date:  2021-03-17       Impact factor: 2.757

6.  Patient-reported outcomes for the immediate loading of mandibular overdentures supported by two implants soon after implant surgery.

Authors:  Yuriko Komagamine; Manabu Kanazawa; Daisuke Sato; Maiko Iwaki; A Miyayasu; Shunsuke Minakuchi
Journal:  J Dent Sci       Date:  2021-07-20       Impact factor: 2.080

7.  Patient-reported outcomes with immediate-loaded two-implant-supported mandibular overdentures: Results of a 5-year prospective study.

Authors:  Yuriko Komagamine; Manabu Kanazawa; Daisuke Sato; Maiko Iwaki; Anna Miyayasu; Shunsuke Minakuchi
Journal:  J Dent Sci       Date:  2021-06-17       Impact factor: 2.080

8.  Masticatory performances and maximum occlusal forces of immediate and conventional loaded two-implant supported overdentures retained by magnetic attachments: preliminary study of randomized controlled clinical trial.

Authors:  Awutsadaporn Katheng; Manabu Kanazawa; Yuriko Komagamine; Anna Miyayasu; Yoko Uehara; Daisuke Sato; Shunsuke Minakuchi
Journal:  Int J Implant Dent       Date:  2021-06-29
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.