Accuracy evaluation of the optical surface monitoring system on EDGE linear accelerator in a phantom study.

Pietro Mancosu1, Antonella Fogliata2, Antonella Stravato1, Stefano Tomatis1, Luca Cozzi1, Marta Scorsetti1.   

Abstract

Frameless stereotactic radiosurgery (SRS) requires dedicated systems to monitor the patient position during the treatment to avoid target underdosage due to involuntary shift. The optical surface monitoring system (OSMS) is here evaluated in a phantom-based study. The new EDGE linear accelerator from Varian (Varian, Palo Alto, CA) integrates, for cranial lesions, the common cone beam computed tomography (CBCT) and kV-MV portal images to the optical surface monitoring system (OSMS), a device able to detect real-time patient׳s face movements in all 6 couch axes (vertical, longitudinal, lateral, rotation along the vertical axis, pitch, and roll). We have evaluated the OSMS imaging capability in checking the phantoms׳ position and monitoring its motion. With this aim, a home-made cranial phantom was developed to evaluate the OSMS accuracy in 4 different experiments: (1) comparison with CBCT in isocenter location, (2) capability to recognize predefined shifts up to 2° or 3cm, (3) evaluation at different couch angles, (4) ability to properly reconstruct the surface when the linac gantry visually block one of the cameras. The OSMS system showed, with a phantom, to be accurate for positioning in respect to the CBCT imaging system with differences of 0.6 ± 0.3mm for linear vector displacement, with a maximum rotational inaccuracy of 0.3°. OSMS presented an accuracy of 0.3mm for displacement up to 1cm and 1°, and 0.5mm for larger displacements. Different couch angles (45° and 90°) induced a mean vector uncertainty < 0.4mm. Coverage of 1 camera produced an uncertainty < 0.5mm. Translations and rotations of a phantom can be accurately detect with the optical surface detector system.
Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  EDGE linear accelerator; Optical surface monitoring system; Patient positioning

Mesh:

Year:  2016        PMID: 26994827     DOI: 10.1016/j.meddos.2015.12.003

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  12 in total

Review 1.  Target delineation and optimal radiosurgical dose for pituitary tumors.

Authors:  Giuseppe Minniti; Mattia Falchetto Osti; Maximillian Niyazi
Journal:  Radiat Oncol       Date:  2016-10-11       Impact factor: 3.481

Review 2.  Re-irradiation of Recurrent Pineal Germ Cell Tumors with Radiosurgery: Report of Two Cases and Review of Literature.

Authors:  Kenneth Wong; Anthony B Opimo; Arthur J Olch; Sean All; Jonathan F Waxer; Desirae Clark; Justine Cheng; Alisha Chlebik; Anat Erdreich-Epstein; Mark D Krieger; Benita Tamrazi; Girish Dhall; Jonathan L Finlay; Eric L Chang
Journal:  Cureus       Date:  2016-04-25

3.  Patient motion tracking for non-isocentric and non-coplanar treatments via fixed frame-of-reference 3D camera.

Authors:  Sergey Gasparyan; Kyle Ko; Lawrie B Skinner; Ryan B Ko; Billy W Loo; Benjamin P Fahimian; Amy S Yu
Journal:  J Appl Clin Med Phys       Date:  2020-02-28       Impact factor: 2.102

4.  Intra-fractional patient motion when using the Qfix Encompass immobilization system during HyperArc treatment of patients with brain metastases.

Authors:  Riho Komiyama; Shingo Ohira; Hikari Ueda; Naoyuki Kanayama; Akira Masaoka; Masaru Isono; Yoshihiro Ueda; Masayoshi Miyazaki; Teruki Teshima
Journal:  J Appl Clin Med Phys       Date:  2021-03-03       Impact factor: 2.102

5.  Optical Surface Management System for Patient Positioning in Interfractional Breast Cancer Radiotherapy.

Authors:  Zhao Ma; Wei Zhang; Yi Su; Peiji Liu; Yinghua Pan; Gang Zhang; Yipeng Song
Journal:  Biomed Res Int       Date:  2018-01-09       Impact factor: 3.411

6.  Orthogonal image pairs coupled with OSMS for noncoplanar beam angle, intracranial, single-isocenter, SRS treatments with multiple targets on the Varian Edge radiosurgery system.

Authors:  Jasmine A Oliver; Patrick Kelly; Sanford L Meeks; Twyla R Willoughby; Amish P Shah
Journal:  Adv Radiat Oncol       Date:  2017-04-26

7.  A study of nonuniform CTV to PTV margin expansion incorporating both rotational and translational uncertainties.

Authors:  Junjie Miao; Yingjie Xu; Yuan Tian; Zhiqiang Liu; Jianrong Dai
Journal:  J Appl Clin Med Phys       Date:  2019-12-02       Impact factor: 2.102

8.  Validating robotic couch isocentricity with 3D surface imaging.

Authors:  Omar El-Sherif; Nicholas B Remmes; Jon J Kruse
Journal:  J Appl Clin Med Phys       Date:  2020-06-15       Impact factor: 2.102

9.  Performance assessment of two motion management systems for frameless stereotactic radiosurgery.

Authors:  Hao Wang; Zhiyong Xu; Kevin Grantham; Yongkang Zhou; Taoran Cui; Yin Zhang; Bo Liu; Xiao Wang; Irina Vergalasova; Meral Reyhan; Joseph Weiner; Shabbar F Danish; Ning Yue; Ke Nie
Journal:  Strahlenther Onkol       Date:  2020-10-12       Impact factor: 3.621

10.  Development and Longitudinal Analysis of Plan-Based Streamlined Quality Assurance on Multiple Positioning Guidance Systems With Single Phantom Setup.

Authors:  Shun Zhou; Junyu Li; Yi Du; Songmao Yu; Meijiao Wang; Hao Wu; Haizhen Yue
Journal:  Front Oncol       Date:  2021-06-16       Impact factor: 6.244

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.