Long-Term Outcomes and Durability of the Mitroflow Aortic Bioprosthesis.

Victor X Mosquera1, Alberto Bouzas-Mosquera2, Carlos Velasco-García1, Javier Muñiz3, Francisco Estévez-Cid1, Francisco Portela-Torron1, José M Herrera-Noreña1, José J Cuenca-Castillo1.   

Abstract

BACKGROUND: This study aims to determine the incidence and causes of structural valve deterioration (SVD) among all models of Mitroflow bioprostheses (A12/LX/DL), as well as to define their long-term clinical and hemodynamic performance. METHODS AND
RESULTS: We retrospectively reviewed a series of 1023 patients who underwent aortic valve replacement with Mitroflow bioprostheses between 2001 and 2014. A small aortic root was found in 22.4% of patients. There were two cases of severe patient-prosthesis mismatch. Only 31 patients developed SVD. The rate of incidence was 8.1 cases per 1000 patient-years. Cumulative incidence of SVD was 1.4% and 3% at five and 10 years, respectively. Freedom from SVD was 97.4% and 88.2% at five and 10 years, respectively. Anticalcification phospholipid reduction treatment (PRT) for model DL was a protective factor for SVD. Multivariable analysis confirmed age <70 years and use of 19 mm valve as independent predictors of SVD. Cumulative survival was 76.6% at five years and 42.3% at 10 years (mean follow-up 3.8 ± 3.1 years). In multivariable analysis, neither the use of small aortic prosthesis (p = 0.18) nor the occurrence of SVD (p = 0.85) was found to be independent predictors of long-term survival.
CONCLUSIONS: Mitroflow valves demonstrate an acceptable rate of SVD and satisfactory long-term hemodynamic performance, particularly in patients with small aortic roots, age >70 years, and cases with severe left ventricular hypertrophy. PRT might contribute to improved long-term durability. doi: 10.1111/jocs.12726 (J Card Surg 2016;31:264-273).
© 2016 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2016        PMID: 26991888     DOI: 10.1111/jocs.12726

Source DB:  PubMed          Journal:  J Card Surg        ISSN: 0886-0440            Impact factor:   1.620


  4 in total

1.  Early structural degeneration of Mitroflow aortic valve: another issue in addition to the mismatch?

Authors:  Giovanni Ruvolo; Calogera Pisano; Carmela Rita Balistreri; Emiliano Maresi; Oreste Fabio Triolo; Vincenzo Argano; Carlo Bassano; Sara Rita Vacirca; Paolo Nardi; Augusto Orlandi
Journal:  J Thorac Dis       Date:  2018-04       Impact factor: 2.895

2.  Balloon-expanding transcatheter aortic valve implantation for degenerated Mitroflow bioprostheses: clinical and echocardiographic long-term outcomes.

Authors:  Victor X Mosquera; Alberto Bouzas-Mosquera; Yago Vilela-González; Carlos Velasco; Jorge Salgado-Fernández; Ramón Calviño-Santos; Nicolás Vázquez-González; José M Vázquez-Rodríguez; José M Herrera-Noreña
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-07-26

3.  Magna ease bioprosthetic aortic valve: mid-term haemodynamic outcomes in 1126 patients.

Authors:  Stephen D Thorp; Jawad Khazaal; Grace Yu; Jessica L Parker; Tomasz A Timek
Journal:  Interact Cardiovasc Thorac Surg       Date:  2021-05-27

4.  Severe Aortic Regurgitation of Early Degenerated Mitroflow Bioprosthesis: From Echocardiographic Diagnosis to Treatment with Valve-in-Valve Transcatheter Aortic Valve Implantation.

Authors:  Matteo Pernigo; Marco Triggiani; Marianna Adamo; Gian Franco Pasini
Journal:  J Cardiovasc Echogr       Date:  2021-05-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.