Literature DB >> 26975735

Organ doses can be estimated from the computed tomography (CT) dose index for cone-beam CT on radiotherapy equipment.

Colin J Martin1, Abdullah Abuhaimed, Marimuthu Sankaralingam, Mohamed Metwaly, David J Gentle.   

Abstract

Cone beam computed tomography (CBCT) systems are fitted to radiotherapy linear accelerators and used for patient positioning prior to treatment by image guided radiotherapy (IGRT). Radiotherapists' and radiographers' knowledge of doses to organs from CBCT imaging is limited. The weighted CT dose index for a reference beam of width 20 mm (CTDIw,ref) is displayed on Varian CBCT imaging equipment known as an On-Board Imager (OBI) linked to the Truebeam linear accelerator. This has the potential to provide an indication of organ doses. This knowledge would be helpful for guidance of radiotherapy clinicians preparing treatments. Monte Carlo simulations of imaging protocols for head, thorax and pelvic scans have been performed using EGSnrc/BEAMnrc, EGSnrc/DOSXYZnrc, and ICRP reference computational male and female phantoms to derive the mean absorbed doses to organs and tissues, which have been compared with values for the CTDIw,ref displayed on the CBCT scanner console. Substantial variations in dose were observed between male and female phantoms. Nevertheless, the CTDIw,ref gave doses within  ±21% for the stomach and liver in thorax scans and 2  ×  CTDIw,ref can be used as a measure of doses to breast, lung and oesophagus. The CTDIw,ref could provide indications of doses to the brain for head scans, and the colon for pelvic scans. It is proposed that knowledge of the link between CTDIw for CBCT should be promoted and included in the training of radiotherapy staff.

Entities:  

Mesh:

Year:  2016        PMID: 26975735     DOI: 10.1088/0952-4746/36/2/215

Source DB:  PubMed          Journal:  J Radiol Prot        ISSN: 0952-4746            Impact factor:   1.394


  3 in total

1.  Dosimetric assessment of the exposure of radiotherapy patients due to cone-beam CT procedures.

Authors:  Mariana Baptista; Salvatore Di Maria; Sandra Vieira; Joana Santos; Joana Pereira; Miguel Pereira; Pedro Vaz
Journal:  Radiat Environ Biophys       Date:  2018-11-03       Impact factor: 1.925

2.  Areas of breast tissue covered in cone beam breast CT imaging.

Authors:  Min Xu; Xue Cheng; Xingyao Cheng; Xilin Lan; Shuzheng Chen; Jiansong Ji
Journal:  Exp Ther Med       Date:  2017-01-27       Impact factor: 2.447

3.  Setup Error Assessment and Correction in Planar kV Image- Versus Cone Beam CT Image-Guided Radiation Therapy: A Clinical Study of Early Breast Cancer Treated With External Beam Partial Breast Irradiation.

Authors:  Wei Wang; Ting Yu; Min Xu; Qian Shao; Yingjie Zhang; Jianbin Li
Journal:  Technol Cancer Res Treat       Date:  2019 Jan-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.