Literature DB >> 26973253

Comparison of seven videolaryngoscopes with the Macintosh laryngoscope in manikins by experienced and novice personnel.

B M A Pieters1, N E R Wilbers2, M Huijzer3, B Winkens4, A A J van Zundert5.   

Abstract

Videolaryngoscopy is often reserved for 'anticipated' difficult airways, but thereby can result in a higher overall rate of complications. We observed 65 anaesthetists, 67 residents in anaesthesia, 56 paramedics and 65 medical students, intubating the trachea of a standardised manikin model with a normal airway using seven devices: Macintosh classic laryngoscope, Airtraq(®) , Storz C-MAC(®) , Coopdech VLP-100(®) , Storz C-MAC D-Blade(®) , GlideScope Cobalt(®) , McGrath Series5(®) and Pentax AWS(®) ) in random order. Time to and proportion of successful intubation, complications and user satisfaction were compared. All groups were fastest using devices with a Macintosh-type blade. All groups needed significantly more attempts using the Airtraq and Pentax AWS (all p < 0.05). Devices with a Macintosh-type blade (classic laryngoscope and C-MAC) scored highest in user satisfaction. Our results underline the importance of variability in device performance across individuals and staff groups, which have important implications for which devices hospital providers should rationally purchase.
© 2016 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Keywords:  airway management; education; equipment; simulation; videolaryngoscopy

Mesh:

Year:  2016        PMID: 26973253     DOI: 10.1111/anae.13413

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  8 in total

1.  [Airway management in preclinical emergency anesthesia with respect to specialty and education].

Authors:  A Luckscheiter; T Lohs; M Fischer; W Zink
Journal:  Anaesthesist       Date:  2020-02-13       Impact factor: 1.041

2.  McGrath Series 5 videolaryngoscope vs Airtraq DL videolaryngoscope for double-lumen tube intubation: A randomized trial.

Authors:  Li Wan; Mingfeng Liao; Li Li; Wei Qian; Rong Hu; Kun Chen; Chuanhan Zhang; Wenlong Yao
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.889

3.  Comparison of VividTrac®, Airtraq®, King Vision®, Macintosh Laryngoscope and a Custom-Made Videolaryngoscope for difficult and normal airways in mannequins by novices.

Authors:  Szilárd Rendeki; Dóra Keresztes; Gábor Woth; Ákos Mérei; Martin Rozanovic; Mátyás Rendeki; József Farkas; Diána Mühl; Bálint Nagy
Journal:  BMC Anesthesiol       Date:  2017-05-26       Impact factor: 2.217

4.  Endotracheal Intubation Criteria and Stress Response: Airtraq versus Macintosh Laryngoscopes - A Prospective Randomized Controlled Trial.

Authors:  Sabry Ibrahim Abdallah; Khaled Mohamed Gaballah
Journal:  Anesth Essays Res       Date:  2019 Jul-Sep

5.  Intubation with channeled versus non-channeled video laryngoscopes in simulated difficult airway by junior doctors in an out-of-hospital setting: A crossover manikin study.

Authors:  Shi Hao Chew; Jonathan Zhao Min Lim; Benjamin Zhao Bin Chin; Jia Xin Chan; Raymond Chern Hwee Siew
Journal:  PLoS One       Date:  2019-10-22       Impact factor: 3.240

6.  Airway Management of Patients with Suspected or Confirmed COVID-19: Survey Results from Physicians from 19 Countries in Latin America.

Authors:  Manuel Granell; Nerea Sanchis; Carlos Delgado; Manuel Lozano; Marcio Pinho; Cecilia Sandoval; Carolina S Romero; Cesar Aldecoa; Juan P Cata; Jorge Neira; Jose De Andres; Alejandro Herreros-Pomares; Guillermo Navarro
Journal:  J Clin Med       Date:  2022-08-12       Impact factor: 4.964

7.  Impact of Macintosh blade size on endotracheal intubation success in intensive care units: a retrospective multicenter observational MacSize-ICU study.

Authors:  Thomas Godet; Audrey De Jong; Côme Garin; Renaud Guérin; Benjamin Rieu; Lucile Borao; Bruno Pereira; Nicolas Molinari; Jean-Etienne Bazin; Matthieu Jabaudon; Gérald Chanques; Emmanuel Futier; Samir Jaber
Journal:  Intensive Care Med       Date:  2022-08-16       Impact factor: 41.787

8.  Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial.

Authors:  In Kyong Yi; Hyun Jeong Kwak; Kyung Cheon Lee; Ji Hyea Lee; Sang Kee Min; Jong Yeop Kim
Journal:  Eur J Med Res       Date:  2020-08-20       Impact factor: 2.175

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.