Literature DB >> 26969529

Effectiveness of hydrogen peroxide and electron-beam irradiation treatment for removal and inactivation of viruses in equine-derived xenografts.

Riccardo Cusinato1, Monia Pacenti2, Thomas Martello3, Paolo Fattori4, Marco Morroni5, Giorgio Palù6.   

Abstract

Bone grafting is a common procedure for bone reconstruction in dentistry, orthopedics, and neurosurgery. A wide range of grafts are currently used, and xenografts are regarded as an interesting alternative to autogenous bone because all mammals share the same bone mineral component composition and morphology. Antigens must be eliminated from bone grafts derived from animal tissues in order to make them biocompatible. Moreover, the processing method must also safely inactivate and/or remove viruses or other potential infectious agents. This study assessed the efficacy of two steps applied in manufacturing some equine-derived xenografts: hydrogen-peroxide and e-beam sterilization treatments for inactivation and removal of viruses in equine bone granules (cortical and cancellous) and collagen and pericardium membranes. Viruses belonging to three different human viral species (Herpes simplex virus type 1, Coxsackievirus B1, and Influenzavirus type A H1N1) were selected and used to spike semi-processed biomaterials. For each viral species, the tissue culture infective dose (TCID50) on cell lines and the number of genome copies through qPCR were assessed. Both treatments were found to be effective at virus inactivation. Considering the model viruses studied, the application of hydrogen peroxide and e-beam irradiation could also be considered effective for processing bone tissue of human origin.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Bone graft; Deantigenation; Electron-beam irradiation; Hydrogen peroxide; Virus inactivation

Mesh:

Substances:

Year:  2016        PMID: 26969529     DOI: 10.1016/j.jviromet.2016.03.001

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  6 in total

1.  Bone integration in acetabular revision hip arthroplasty using equine-derived bone grafts: a retrospective study.

Authors:  Nicola Piolanti; Andrea Del Chiaro; Fabrizio Matassi; Lorenzo Nistri; Angelo Graceffa; Massimiliano Marcucci
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-12-19

2.  Inactivation of porcine epidemic diarrhea virus with electron beam irradiation under cold chain conditions.

Authors:  Yan Liu; Yang Shao; Lu Wang; Weilai Lu; Shihua Li; Diandou Xu; Yu Vincent Fu
Journal:  Environ Technol Innov       Date:  2022-06-06

3.  Coxsackieviruses B3 infection of myocardial microvascular endothelial cells activates fractalkine via the ERK1/2 signaling pathway.

Authors:  Jili Wen; Congxin Huang
Journal:  Mol Med Rep       Date:  2017-09-20       Impact factor: 2.952

Review 4.  Hydrogen peroxide and viral infections: A literature review with research hypothesis definition in relation to the current covid-19 pandemic.

Authors:  Arturo Armone Caruso; Antonio Del Prete; Antonio Ivan Lazzarino
Journal:  Med Hypotheses       Date:  2020-06-01       Impact factor: 1.538

5.  Electron Beam Irradiated Corneal Versus Gamma-Irradiated Scleral Patch Graft Erosion Rates in Glaucoma Drainage Device Surgery.

Authors:  Ross M Passo; Zachary B Hoskins; Khoa D Tran; Corrina Patzer; Beth Edmunds; John C Morrison; Mansi Parikh; Hana L Takusagawa; Shandiz Tehrani
Journal:  Ophthalmol Ther       Date:  2019-06-06

6.  Steam Sterilization of Equine Bone Block: Morphological and Collagen Analysis.

Authors:  R Lo Giudice; G Rizzo; A Centofanti; A Favaloro; D Rizzo; G Cervino; R Squeri; B G Costa; V La Fauci; G Lo Giudice
Journal:  Biomed Res Int       Date:  2018-08-13       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.