| Literature DB >> 26968038 |
Heidi Weberruß1, Raphael Pirzer2, Robert Dalla Pozza2, Heinrich Netz2, Renate Oberhoffer1.
Abstract
Carotid intima-media thickness (cIMT) is a surrogate marker of early atherosclerotic changes in children. cIMT-studies are hard to compare, due to variations in ultrasound protocols, especially regarding the common carotid artery (CCA) segment measured in relation to the bulb. This study's purpose was therefore to compare two distinct CCA segments in children, to see if cIMT values differ substantially according to the site of measurement. cIMT was assessed after power calculation in 30 children (15 girls) aged 8-17, using B-Mode ultrasound (5-13 MHz) at two CCA locations. The first measurement was performed over a distance of 1 cm immediately after the bulb (A), the second 1cm proximal the bulb (B) over the same distance of 1cm length. Means of end-diastolic far wall cIMT were compared between measurement A and B. cIMT in 30 participants was 0.51±0.06 mm for measurement A and 0.51±0.05 mm for measurement B. Results did not differ significantly (p = .947) over a distance of 2 cm after the bulb. According to our results, studies measuring CCA IMT within the first 2 cm, either close to the bulb or further proximal, can be compared. This will improve interpretation of data and application of reference values.Entities:
Mesh:
Year: 2016 PMID: 26968038 PMCID: PMC4788416 DOI: 10.1371/journal.pone.0149057
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Summary of ultrasound B-mode studies measuring intima-media thickness in children and adolescents with different protocols.
| Subjects (females) | Age (years) | IMT (mm±SD) /range (mm) | CCA | ICA | Bulb | Measurement location | Cardiac Cycle | left side | right side | far wall | near wall | Angle | IMT detection | IMT calculation | |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Aggoun [ | n = 57 | 11.1±3 | 0.5–0.53±0.03 | x | 1-2cm proximal the BIF | end-diastolic | x | N/A | automatic | mean | |||||
| Dawson [ | n = 635 (322) | 11–34 | 0.49±0.04 | x | x | x | N/A | N/A | x | x | x | x | 3 diff. angles. | N/A | Mean |
| Iannuzzi [ | n = 100 (39) | 6–14 | 0.51–0.54 | x | 1cm distance from BIF | N/A | x | x | x | x | N/A | N/A | max | ||
| Ishizu [ | n = 60 (33) | 5–14 | 0.44±0.05 | x | 1-2cm proximal the bulb | end-diastolic | x | x | x | ant./ lat. | N/A | mean and max | |||
| Jarvisalo [ | n = 75 (27) | 7–14 | 0.42–0.47±0.03 | x | x | 1-2cm proximal the bulb, left bulb | end-diastolic | x | x | x | ant. oblique/ lat. | caliper | mean and max | ||
| Jarvisalo [ | n = 88 (33) | 11±2 | 0.42–0.47±0.04 | x | 1-2cm proximal the bulb | end-diastolic | x | x | x | ant. oblique/ lat. | caliper | mean | |||
| Krantz [ | n = 229 (131) | 12–25 | 0.54–0.56±0.06 | x | distal CCA | N/A | x | x | N/A | automatic | N/A | ||||
| Krebs [ | n = 100 (53) | 5–18 | 0.54 | x | 1cm proximal the bulb | N/A | x | x | lat./ post.oblique | automatic | mean and max | ||||
| Lande [ | n = 56 | 10–18 | 0.53–0.93 | x | 1cm proximal BIF | N/A | x | x | N/A | N/A | mean | ||||
| Lavrencic [ | n = 56 (32) | 11–27 | 0.49–0.71 | x | 1cm proximal ICA, BIF, 1cm distal BIF | N/A | x | x | x | N/A | N/A | max | |||
| Litwin [ | n = 110 (40) | 6–20 | 0.41–0.45±0.05 | x | 1-2cm below BIF | N/A | x | x | x | N/A | N/A | N/A | |||
| Menees [ | n = 49 (22) | 6–19 | 0.46±0.04 | x | 2cm proximal BIF | CRS/ non-CRS | x | x | x | N/A | semi-automatic | mean | |||
| Meyer [ | n = 52 (29) | 9–16 | 0.39±0.05/ 0.49±0.08 | x | x | 1cm distal the bulb, BIF | N/A | x | x | x | x | N/A | N/A | mean and max | |
| Mittelman [ | n = 599 (307) | 5–20 | 0.38±0.04 | x | 1cm proximal BIF | N/A | x | x | N/A | automatic | N/A | ||||
| Sass [ | n = 193 (108) | 10–24 | 0.48–0. 5±0.05 | x | 3cm proximal BIF | N/A | x | x | x | N/A | automatic | mean | |||
| Böhm [ | n = 267 (143) | 6–17 | 0.51 | x | 8-18mm proximal BIF | end-systolic | x | x | N/A | semi-automatic | mean | ||||
| Jourdan [ | n = 247 (127) | 10–20 | 0.38–0.4±0.04 | x | 1-2cm proximal BIF | N/A | x | x | x | N/A | caliper | N/A | |||
| Doyon [ | n = 1051 | 6–18 | 0.37–0.41 | x | 1-2cm proximal BIF | N/A | x | x | x | N/A | caliper/semi-automatic | N/A | |||
| Pauciullo [ | n = 94 (45) | 2–14 | 0.39–0.4±0.03 | x | 1cm proximal BIF | systolic | x | x | x | x | ant./post. | N/A | mean and max | ||
| Reinehr [ | n = 124 (75) | 9–13 | 0.4–0.6 | x | near BIF | N/A | x | x | x | N/A | N/A | max | |||
| Singh [ | n = 66 (31) | 10–18 | 0.32±0.08/ 0.33±0.05 | x | 1cm proximal the bulb | N/A | x | x | x | N/A | N/A | N/A | |||
| Sorof [ | n = 32 (7) | 13.9 | 0.64±0.12 | x | 2cm distal the flow divider | N/A | x | x | x | N/A | digital caliper | max | |||
| Tonstad [ | n = 90 (29) | 10–19 | 0.48±0.07 | x | 1cm proximal and distal the bulb | end-diastolic | x | x | N/A | N/A | mean and max | ||||
| Virkola [ | n = 46 (16) | 2.7–19 | 0.33–0.5±0.1 | x | 2cm below BIF | end-diastolic | x | x | x | N/A | electronic caliper | N/A | |||
| Weberruß [ | n = 690 (380) | 7–17 | 0.46±0.03 | x | 1cm proximal the bulb, | end-diastolic | x | x | x | N/A | semi-automatic | mean | |||
| Woo [ | n = 72 (30) | 7–12 | 0.45–0.49±0.04 | x | 1cm distal the bulb | N/A | x | x | x | ant/ lat./ post.oblique | automatic | max |
IMT, intima-media thickness; CCA, common carotid artery; ICA, internal carotid artery; BULB, bulbus; BIF, bifurcation
Fig 1B-Mode Ultrasound image of the common carotid artery.
Segment A defines the first measurement about a distance of 1cm immediately proximal to the bulb. Segment B defines the second measurement over the same length of 1cm proximal to segment A.
Anthropometric data and cIMT values of study participants in mean±SD.
| Boys (n = 15) | Girls (n = 15) | p-value | |
|---|---|---|---|
| 13.1±3.1 | 12.9±2.9 | .854 | |
| 158.4±17.2 | 152.1±12.2 | .260 | |
| 53±23.2 | 46.5±12.1 | .653 | |
| 19.7±3 | 20.2±4.9 | .935 | |
| 0.26±1.1 | 0.23±0.9 | .928 | |
| 0.47±0.04 | 0.47±0.04 | .804 | |
| -0.02±1.16 | 0.21±1.02 | .566 |
a SDS is for Standard Deviation Scores, according to the german reference population for Body Mass Index (BMI) [39] and carotid intima-media thickness (cIMT) [26].
Fig 2Bland-Altman analysis of measurement A and B.