Literature DB >> 26963349

Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges.

T Y Abay1, P A Kyriacou.   

Abstract

Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of this study was to investigate all the techniques simultaneously on healthy subjects during vascular occlusion challenges. Sensors were attached on the forearm (NIRS and LDF) and fingers (PPG and PO) of 19 healthy volunteers. Different degrees of vascular occlusion were induced by inflating a pressure cuff on the upper arm. The responses of tissue oxygenation index (NIRS), tissue haemoglobin index (NIRS), flux (LDF), perfusion index (PPG), and arterial oxygen saturation (PO) have been recorded and analyzed. Moreover, the optical densities were calculated from slow varying dc PPG, in order to distinguish changes in venous blood volumes. The indexes showed significant changes (p  <  0.05) in almost all occlusions, either venous or over-systolic occlusions. However, differentiation between venous and arterial occlusion by LDF may be challenging and the perfusion index (PI) may not be adequate to indicate venous occlusions. Optical densities may be an additional tool to detect venous occlusions by PPG.

Entities:  

Mesh:

Year:  2016        PMID: 26963349     DOI: 10.1088/0967-3334/37/4/503

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  6 in total

1.  Blood oxygenation and flow measurements using a single 720-nm tunable V-cavity laser.

Authors:  Yafei Feng; Haoyu Deng; Xin Chen; Jian-Jun He
Journal:  Biomed Opt Express       Date:  2017-07-03       Impact factor: 3.732

2.  Photoplethysmography for the Assessment of Haemorheology.

Authors:  Haneen Njoum; Panayiotis A Kyriacou
Journal:  Sci Rep       Date:  2017-05-03       Impact factor: 4.379

3.  Impact of Fitness Status on the Optically Measured Hemodynamic Indexes.

Authors:  B I Kuznik; Y N Smolyakov; S O Davydov; N N Tsybikov; O G Maksimova; A V Malinina; L Shenkman; A Kaminsky; I Fine
Journal:  J Healthc Eng       Date:  2018-01-09       Impact factor: 2.682

Review 4.  An Overview of In Vitro, In Vivo, and Computational Techniques for Cancer-Associated Angiogenesis Studies.

Authors:  Heshu Sulaiman Rahman; Bee Ling Tan; Hemn Hassan Othman; Max Stanley Chartrand; Yashwant Pathak; Syam Mohan; Rasedee Abdullah; Noorjahan Banu Alitheen
Journal:  Biomed Res Int       Date:  2020-12-10       Impact factor: 3.411

Review 5.  Noninvasive hemoglobin sensing and imaging: optical tools for disease diagnosis.

Authors:  Michaela Taylor-Williams; Graham Spicer; Gemma Bale; Sarah E Bohndiek
Journal:  J Biomed Opt       Date:  2022-08       Impact factor: 3.758

6.  Compact dual-mode diffuse optical system for blood perfusion monitoring in a porcine model of microvascular tissue flaps.

Authors:  Seung Yup Lee; Julia M Pakela; Michael C Helton; Karthik Vishwanath; Yooree G Chung; Noah J Kolodziejski; Christopher J Stapels; Daniel R McAdams; Daniel E Fernandez; James F Christian; Jameson O'Reilly; Dana Farkas; Brent B Ward; Stephen E Feinberg; Mary-Ann Mycek
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.