Literature DB >> 26961915

Polydimethylsiloxane/covalent triazine frameworks coated stir bar sorptive extraction coupled with high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental water samples.

Cheng Zhong1, Man He1, Huaping Liao1, Beibei Chen1, Cheng Wang1, Bin Hu2.   

Abstract

In this work, covalent triazine frameworks (CTFs) were introduced in stir bar sorptive extraction (SBSE) and a novel polydimethylsiloxane(PDMS)/CTFs stir bar coating was prepared by sol-gel technique for the sorptive extraction of eight phenols (including phenol, 2-chlorophenol, 2-nitrophenol, 4-nitrophenol, 2,4-dimethylphenol, p-chloro-m-cresol and 2,4-dichlorophenol, 2,4,6-trichlorophenol) from environmental water samples followed by high performance liquid chromatography-ultraviolet (HPLC-UV) detection. The prepared PDMS/CTFs coated stir bar showed good preparation reproducibility with the relative standard deviations (RSDs) ranging from 3.5 to 5.7% (n=7) in one batch, and from 3.7 to 9.3% (n=7) among different batches. Several parameters affecting SBSE of eight target phenols including extraction time, stirring rate, sample pH, ionic strength, desorption solvent and desorption time were investigated. Under the optimal experimental conditions, the limits of detection (LODs, S/N=3) were found to be in the range of 0.08-0.30 μg/L. The linear range was 0.25-500 μg/L for 2-nitrophenol, 0.5-500 μg/L for phenol, 2-chlorophenol, 4-nitrophenol as well as 2,4-dimethylphenol, and 1-500 μg/L for p-chloro-m-cresol, 2,4-dichlorophenol as well as 2,4,6-trichlorophenol, respectively. The intra-day relative standard deviations (RSDs) were in the range of 4.3-9.4% (n=7, c=2 μg/L) and the enrichment factors ranged from 64.9 to 145.6 fold (theoretical enrichment factor was 200-fold). Compared with commercial PDMS coated stir bar (Gerstel) and PEG coated stir bar (Gerstel), the prepared PDMS/CTFs stir bar showed better extraction efficiency for target phenol compounds. The proposed method was successfully applied to the analysis of phenols in environmental water samples and good relative recoveries were obtained with the spiking level at 2, 10, 50 μg/L, respectively.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Environmental water samples; High performance liquid chromatography-ultraviolet detector; Phenols; Polydimethylsiloxane/covalent triazine frameworks; Stir bar sorptive extraction

Mesh:

Substances:

Year:  2016        PMID: 26961915     DOI: 10.1016/j.chroma.2016.02.073

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

Review 1.  Recent Advances of Triazine-Based Materials for Adsorbent Based Extraction Techniques.

Authors:  Min Sun; Sen Han; Juanjuan Feng; Chunying Li; Xiangping Ji; Jiaqing Feng; Haili Sun
Journal:  Top Curr Chem (Cham)       Date:  2021-05-04

2.  An amino-functionalized ordered mesoporous polymer as a fiber coating for solid phase microextraction of phenols prior to GC-MS analysis.

Authors:  Lin Li; Lijin Huang; Shutang Sun; Qian Yan; Qin Shuai; Shenghong Hu
Journal:  Mikrochim Acta       Date:  2019-09-02       Impact factor: 5.833

3.  [Application progress of covalent organic framework materials in extraction of toxic and harmful substances].

Authors:  Wenmin Zhang; Guancheng Liu; Wende Ma; Min Fang; Lan Zhang
Journal:  Se Pu       Date:  2022-07

Review 4.  Covalent Organic Frameworks in Sample Preparation.

Authors:  Javier González-Sálamo; Gabriel Jiménez-Skrzypek; Cecilia Ortega-Zamora; Miguel Ángel González-Curbelo; Javier Hernández-Borges
Journal:  Molecules       Date:  2020-07-20       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.