A comparative study on the use of digital panoramic and periapical radiographs to assess proximal bone height around dental implants.

Zvi Gutmacher, Eli E Machtei, Ilan Hirsh, Hadar Zigdon-Giladi, Jacob Horwitz.   

Abstract

OBJECTIVE: The purpose of this study was to compare periapical radiographs (PA) and panoramic radiographs (PAN) in the measurement of proximal bone height around implants. METHOD AND MATERIALS: Patients files that contained digital PAN and PA together with information on implant lengths and diameters were selected for this study. For each radiograph, the implant size served as reference for calibration. Proximal radiographic bone levels and the linear distance between the bone crest and implant shoulder were measured twice by one examiner. Paired t test was used to assess intra-examiner variability and differences between the two radiographic methods. Correlation was then assessed using Pearson correlation coefficient test. Significance level was determined at 5%.
RESULTS: For the PAN measurements, the median mesial distances from bone crest to implant shoulder were 0.53 and 0.56 mm (first and second sets, P = .53). Likewise, for distal measurements these readings were 0.92 and 0.86 mm respectively (P = .66). For PA measurements, the corresponding measurements were 0.33 and 0.44 mm (P = .48) and 0.99 and 0.99 mm (P = .42), respectively. When PAN and PA measurements were compared, no statistically significant differences were detected between the two radiographic modalities. A very high positive correlation (r > 0.91) was attained for the PAN - PA measurements (P < .0001).
CONCLUSION: PAN are potentially as reliable and reproducible as PA for the assessment of proximal bone height around dental implants.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 26949765     DOI: 10.3290/j.qi.a35704

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  2 in total

Review 1.  Two-dimensional radiographs versus cone-beam computed tomography in planning mini-implant placement: A systematic review.

Authors:  Gabriela-Franco-da Rosa Caetano; Mariana-Quirino-Silveira Soares; Luciana-Butini Oliveira; José-Luiz-Cintra Junqueira; Monikelly-do Carmo-Chagas Nascimento
Journal:  J Clin Exp Dent       Date:  2022-08-01

2.  Effect of Smoking and Locations of Dental Implants on Peri-Implant Parameters: 3-Year Follow-Up.

Authors:  Emre Mumcu; Süleyman Çağatay Dayan
Journal:  Med Sci Monit       Date:  2019-08-15
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.