A study on the changes in attractive force of magnetic attachments for overdenture.

Han-Wool Leem1, In-Ho Cho1, Jong-Hyuk Lee1, Yu-Sung Choi1.   

Abstract

PURPOSE: Although magnetic attachment is used frequently for overdenture, it is reported that attractive force can be decreased by abrasion and corrosion. The purpose of this study was to establish the clinical basis about considerations and long term prognosis of overdenture using magnetic attachments by investigating the change in attractive force of magnetic attachment applied to the patients.
MATERIALS AND METHODS: Among the patients treated with overdenture using magnetic attachments in Dankook University Dental Hospital, attractive force records of 61 magnetic attachments of 20 subjects who re-visited from July 2013 to June 2014 were analyzed. Dental magnet tester (Aichi Micro Intelligent Co., Aichi, Japan) was used for measurement. The magnetic attachments used in this study were Magfit IP-B Flat, Magfit DX400, Magfit DX600 and Magfit DX800 (Aichi Steel Co., Aichi, Japan) filled with Neodymium (NdFeB), a rare-earth magnet.
RESULTS: Reduction ratio of attractive force had no significant correlation with conditional variables to which attachments were applied, and was higher when the maintenance period was longer (P<.05, r=.361). Reduction ratio of attractive force was significantly higher in the subject group in which attachments were used over 9 years than within 9 years (P<.05). Furthermore, 16.39% of total magnetic attachments showed detachment of keeper or assembly.
CONCLUSION: Attractive force of magnetic attachment is maintained regardless of conditional variables and reduction ratio increased as the maintenance period became longer. Further study on adhesive material, attachment method and design improvement to prevent detachment of magnetic attachment is needed.

Entities:  

Keywords:  Attractive force; Magnetic attachment; Overdenture

Year:  2016        PMID: 26949482      PMCID: PMC4769893          DOI: 10.4047/jap.2016.8.1.9

Source DB:  PubMed          Journal:  J Adv Prosthodont        ISSN: 2005-7806            Impact factor:   1.904


  31 in total

1.  Prosthetic aspects of osseointegrated fixtures supporting overdentures. A 4-year report.

Authors:  I Naert; M Quirynen; G Theuniers; D van Steenberghe
Journal:  J Prosthet Dent       Date:  1991-05       Impact factor: 3.426

2.  A randomised clinical trial on the influence of splinted and unsplinted oral implants in mandibular overdenture therapy. A 3-year report.

Authors:  I E Naert; S Gizani; M Vuylsteke; D van Steenberghe
Journal:  Clin Oral Investig       Date:  1997-06       Impact factor: 3.573

3.  An overdenture survey: preliminary report.

Authors:  P V Reitz; M G Weiner; B Levin
Journal:  J Prosthet Dent       Date:  1977-03       Impact factor: 3.426

4.  Prevention of complete denture problems by use of "overdentures".

Authors:  C A Dodge
Journal:  J Prosthet Dent       Date:  1973-10       Impact factor: 3.426

5.  Conventional rehabilitation of edentulous patients: the impact on oral health-related quality of life and patient satisfaction.

Authors:  Janice S Ellis; Nanita D Pelekis; J Mark Thomason
Journal:  J Prosthodont       Date:  2007 Jan-Feb       Impact factor: 2.752

6.  Magnetic retention for overdentures. Part II.

Authors:  B R Gillings
Journal:  J Prosthet Dent       Date:  1983-05       Impact factor: 3.426

7.  Photoelastic stess analysis of overdenture attachments.

Authors:  H H Thayer; A A Caputo
Journal:  J Prosthet Dent       Date:  1980-06       Impact factor: 3.426

8.  Magnetic retention for complete and partial overdentures. Part I.

Authors:  B R Gillings
Journal:  J Prosthet Dent       Date:  1981-05       Impact factor: 3.426

9.  Alveolar bone loss in overdentures: a 5-year study.

Authors:  R J Crum; G E Rooney
Journal:  J Prosthet Dent       Date:  1978-12       Impact factor: 3.426

10.  Prospective clinical evaluation of mandibular implant overdentures: Part II--Patient satisfaction and preference.

Authors:  D R Burns; J W Unger; R K Elswick; J A Giglio
Journal:  J Prosthet Dent       Date:  1995-04       Impact factor: 3.426

View more
  1 in total

1.  Corrosion behaviours of the dental magnetic keeper complexes made by different alloys and methods.

Authors:  Min-Ke Wu; Ning Song; Fei Liu; Liang Kou; Xiao-Wen Lu; Min Wang; Hang Wang; Jie-Fei Shen
Journal:  Int J Oral Sci       Date:  2016-09-29       Impact factor: 6.344

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.