Literature DB >> 26946947

Simultaneous Detection of Tumor Cell Apoptosis Regulators Bcl-2 and Bax through a Dual-Signal-Marked Electrochemical Immunosensor.

Shiwei Zhou1, Yingying Wang1, Jun-Jie Zhu1.   

Abstract

B-cell lymphoma 2 (Bcl-2) and Bcl-2-associated X protein (Bax) are often used to monitor the apoptosis of tumor cells and evaluate cancer drug effect. In this work, a novel sandwich-type dual-signal-marked electrochemical biosensor was fabricated for simultaneous detection of Bcl-2 and Bax proteins. Reduced graphene oxide (RGO) layers were used as substrate to immobilize Bcl-2 and Bax antibodies for further capturing target antigens. CdSeTe@CdS quantum dots (QDs) and Ag nanoclusters (NCs) with antibody modification and mesoporous silica amplification were used as signal probes, which were proportional to the amount of Bcl-2 and Bax antigens. Mesoporous SiO2 can provide a larger surface area, more effectively charged by ethylene imine polymer or poly(diallyldimethylammonium chloride) to adsorb more probes. The Bcl-2 and Bax proteins were determined indirectly by the detection of oxidation peak currents of Cd and Ag using anodic stripping voltammetry, showing a good linear relationship in the protein concentration range from 1 ng/mL to 250 ng/mL. The detection limit of trace protein level was ∼0.5 fmol. The biosensor was further introduced to investigate Bcl-2 and Bax expressions from nilotinib-treated chronic myeloid leukemia K562 cells. With the increase of drug dosage and incubation time, the up-regulation for Bax and down-regulation for Bcl-2 were observed, which indicated that the apoptosis level of K562 cells could be regulated by Bcl-2 family. The ratio of Bax/Bcl-2 was further calculated for evaluation of its drug effect and apoptosis level. The limited cell amount for detection reached less than 1 × 10(3) cells, much lower than traditional methods. Furthermore, completely independent detection step and stable acid solutions containing Ag(+) and Cd(2+) for long-time storage contribute to reducing the error from the sample differences and avoiding the potential errors from the photodegradation of fluorescent probes, enzymolysis of DNA, or inactivation of enzyme during an excess experimental period.

Entities:  

Keywords:  Bax; Bcl-2; CML; apoptosis; electrochemical immunosensor

Mesh:

Substances:

Year:  2016        PMID: 26946947     DOI: 10.1021/acsami.6b01010

Source DB:  PubMed          Journal:  ACS Appl Mater Interfaces        ISSN: 1944-8244            Impact factor:   9.229


  13 in total

1.  Photoelectrochemical aptasensor for sulfadimethoxine using g-C3N4 quantum dots modified with reduced graphene oxide.

Authors:  Xueming Dang; Huimin Zhao; Xiaona Wang; Tangnuer Sailijiang; Shuo Chen; Xie Quan
Journal:  Mikrochim Acta       Date:  2018-06-29       Impact factor: 5.833

2.  A Potential Anti-cancer Compound Separated from the Chloroform Extract of the Chinese Medicine Formula Shenqi San.

Authors:  Lu Shi; Yi-Jun Tu; Si-Qi Ye; Yu Xia; Chao-Zhi Ma; Xiao-Zhi Peng; Yan-Wen Liu; Zhong-Zhu Ai; Peng-Tao You
Journal:  Curr Med Sci       Date:  2020-03-13

Review 3.  The mechanisms of graphene-based materials-induced programmed cell death: a review of apoptosis, autophagy, and programmed necrosis.

Authors:  Lingling Ou; Shaoqiang Lin; Bin Song; Jia Liu; Renfa Lai; Longquan Shao
Journal:  Int J Nanomedicine       Date:  2017-09-07

Review 4.  Multiplexed Electrochemical Immunosensors for Clinical Biomarkers.

Authors:  Paloma Yáñez-Sedeño; Susana Campuzano; José M Pingarrón
Journal:  Sensors (Basel)       Date:  2017-04-27       Impact factor: 3.576

Review 5.  Nanomaterials for Electrochemical Immunosensing.

Authors:  Mingfei Pan; Ying Gu; Yaguang Yun; Min Li; Xincui Jin; Shuo Wang
Journal:  Sensors (Basel)       Date:  2017-05-05       Impact factor: 3.576

Review 6.  Advantages of Graphene Biosensors for Human Stem Cell Therapy Potency Assays.

Authors:  Roxana-Maria Amărandi; Diana F Becheru; George M Vlăsceanu; Mariana Ioniță; Jorge S Burns
Journal:  Biomed Res Int       Date:  2018-05-29       Impact factor: 3.411

Review 7.  Advances in Electrochemical and Acoustic Aptamer-Based Biosensors and Immunosensors in Diagnostics of Leukemia.

Authors:  Tibor Hianik
Journal:  Biosensors (Basel)       Date:  2021-05-31

8.  AMPK activation-dependent autophagy compromises oleanolic acid-induced cytotoxicity in human bladder cancer cells.

Authors:  Yarong Song; Peng Zhang; Yadong Sun; Xuechao Li; Lifeng Chen; Yajun Xiao; Yifei Xing
Journal:  Oncotarget       Date:  2017-07-04

Review 9.  Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis.

Authors:  Il-Hoon Cho; Dong Hyung Kim; Sangsoo Park
Journal:  Biomater Res       Date:  2020-02-04

Review 10.  Nanobioconjugates for Signal Amplification in Electrochemical Biosensing.

Authors:  Sebastian Cajigas; Jahir Orozco
Journal:  Molecules       Date:  2020-08-03       Impact factor: 4.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.