Literature DB >> 26940824

[Custom-fit kinematic alignment in total knee arthroplasty using PSI. The story of ShapeMatch technology].

T Calliess1, M Ettinger2, C Stukenborg-Colsmann2, H Windhagen2.   

Abstract

BACKGROUND: The story of ShapeMatch® custom-fit cutting guides for primary total knee arthroplasty (TKA) is special compared to other available techniques. First, it was the first such patient-specific instrument (PSI) on the market. Second, the underlying philosophy of kinematic alignment is unique compared to other competitors. Finally, it is the only PSI technique that has been withdrawn from the market. OBJECTIVES AND METHODS: The objective of this paper is to summarize the history of the ShapeMatch® technology and to review the current literature regarding clinical evidence for kinematically aligned TKA. RESULTS AND
CONCLUSIONS: In the recent literature, faster rehabilitation, better knee function and higher patient satisfaction are described for kinematically aligned TKA compared to conventional alignment. However, there is also evidence for inaccuracies by using the PSI technology as a possible cause of treatment failures. Due to those problems, this technology was recalled from the market. As an alternative method to achieve kinematic alignment in TKA, manual as well as computer-assisted techniques are currently under development and are discussed here.

Entities:  

Keywords:  Kinematic alignment; Patient specific intruments; Primary total knee arthroplasty; Review; Stryker ShapeMatch®

Mesh:

Year:  2016        PMID: 26940824     DOI: 10.1007/s00132-016-3240-2

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  14 in total

1.  Kinematically versus mechanically aligned total knee arthroplasty.

Authors:  H Gene Dossett; George J Swartz; Nicolette A Estrada; George W LeFevre; Bertram G Kwasman
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

2.  Custom-fit total knee arthroplasty (OtisKnee) results in malalignment.

Authors:  Brian A Klatt; Nitin Goyal; Matthew S Austin; William J Hozack
Journal:  J Arthroplasty       Date:  2008-01       Impact factor: 4.757

Review 3.  [Computer-assisted systems in total knee arthroplasty. Useful aid or only additional costs].

Authors:  T Calliess; M Ettinger; H Windhagen
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

Review 4.  [Kinematic alignment in total knee arthroplasty : Concept, evidence base and limitations].

Authors:  T Calliess; M Ettinger; C Stukenborg-Colsmann; H Windhagen
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

5.  Do patient-specific guides improve coronal alignment in total knee arthroplasty?

Authors:  Ryan M Nunley; Bradley S Ellison; Jinjun Zhu; Erin L Ruh; Stephen M Howell; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2011-12-20       Impact factor: 4.176

6.  A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results.

Authors:  H G Dossett; N A Estrada; G J Swartz; G W LeFevre; B G Kwasman
Journal:  Bone Joint J       Date:  2014-07       Impact factor: 5.082

7.  The John Insall Award: No Functional Benefit After Unicompartmental Knee Arthroplasty Performed With Patient-specific Instrumentation: A Randomized Trial.

Authors:  Matthieu Ollivier; Sebastien Parratte; Alexandre Lunebourg; Elke Viehweger; Jean-Noel Argenson
Journal:  Clin Orthop Relat Res       Date:  2016-01       Impact factor: 4.176

8.  Results of an initial experience with custom-fit positioning total knee arthroplasty in a series of 48 patients.

Authors:  Stephen M Howell; Kyle Kuznik; Maury L Hull; Robert A Siston
Journal:  Orthopedics       Date:  2008-09       Impact factor: 1.390

9.  Femoral bone and cartilage wear is predictable at 0° and 90° in the osteoarthritic knee treated with total knee arthroplasty.

Authors:  Denis Nam; Kenneth M Lin; Stephen M Howell; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-20       Impact factor: 4.342

10.  Accurate alignment and high function after kinematically aligned TKA performed with generic instruments.

Authors:  Stephen M Howell; Stelios Papadopoulos; Kyle T Kuznik; Maury L Hull
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-08-15       Impact factor: 4.342

View more
  1 in total

Review 1.  [Limits of kinematic alignment and recommendations for its safe application].

Authors:  Tilman Calliess; Max Ettinger
Journal:  Orthopade       Date:  2020-07       Impact factor: 1.087

  1 in total