Note: Durability analysis of optical fiber hydrogen sensor based on Pd-Y alloy film.

Peng-cheng Huang1, You-ping Chen1, Gang Zhang1, Han Song1, Yi Liu2.   

Abstract

The Pd-Y alloy sensing film has an excellent property for hydrogen detection, but just for one month, the sensing film's property decreases seriously. To study the failure of the sensing film, the XPS spectra analysis was used to explore the chemical content of the Pd-Y alloy film, and analysis results demonstrate that the yttrium was oxidized. The paper presented that such an oxidized process was the potential reason of the failure of the sensing film. By understanding the reason of the failure of the sensing film better, we could improve the manufacturing process to enhance the property of hydrogen sensor.

Entities:  

Year:  2016        PMID: 26931903     DOI: 10.1063/1.4941749

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  Modeling of hydrogen atom diffusion and response behavior of hydrogen sensors in Pd-Y alloy nanofilm.

Authors:  Yi Liu; Yanli Li; Pengcheng Huang; Han Song; Gang Zhang
Journal:  Sci Rep       Date:  2016-11-15       Impact factor: 4.379

Review 2.  Optical Fiber Grating Hydrogen Sensors: A Review.

Authors:  Jixiang Dai; Li Zhu; Gaopeng Wang; Feng Xiang; Yuhuan Qin; Min Wang; Minghong Yang
Journal:  Sensors (Basel)       Date:  2017-03-12       Impact factor: 3.576

  2 in total