Literature DB >> 26927879

Development of a readily applied method to quantify ractopamine residue in meat and bone meal by QuEChERS-LC-MS/MS.

Vanessa Gressler1, Angélica R L Franzen2, Gustavo J M M de Lima3, Fernando C Tavernari4, Osmar A Dalla Costa5, Vivian Feddern6.   

Abstract

A QuEChERS method of ractopamine (RCT) residue detection in swine meat and bone meal (MBM) samples was demonstrated. Samples were hydrolyzed with protease and β-glucuronidase prior to QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) extraction and clean-up. Samples were analyzed in a Liquid Chromatography (equipped with ACE 5 C18 column under gradient elution) coupled with a triple quadrupole mass spectrometer operating in positive electrospray ionization mode (using multiple reaction monitoring, MRM). The method was validated for its specificity, decision limit (CCα), detection capability (CCβ), recovery, repeatability, reproducibility, linearity, limits of detection (LODs), quantification (LOQs), and stability according to international guidelines (European Commission Decision 2002/657/EC). Recoveries ranged from 96.3 to 107.0%. Repeatability and reproducibility showed both RSD<5.7% and 3.1%, respectively. LODs and LOQs were 1.91 and 6.36 ppb, respectively. CCα and CCβ values were 1.91 and 2.37 ppb, respectively. RCT showed good stability for spiked samples and real samples when the concentration was higher, otherwise at lower concentration stability was lower. The proposed method can be successfully applied on a regular basis for the determination of RCT in MBM, demonstrating the usefulness of the method as a tool for compliance monitoring in regulatory laboratories.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Dispersive solid phase extraction; Feed ingredient; Mass spectrometer; Method development; Swine; β-agonist

Mesh:

Substances:

Year:  2016        PMID: 26927879     DOI: 10.1016/j.jchromb.2016.01.063

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  6 in total

1.  Gold nanoparticle-based colorimetric ELISA for quantification of ractopamine.

Authors:  Shuaijuan Han; Tianjiao Zhou; Bingjie Yin; Pingli He
Journal:  Mikrochim Acta       Date:  2018-03-07       Impact factor: 5.833

2.  Simultaneous Determination of Nitroimidazoles and Quinolones in Honey by Modified QuEChERS and LC-MS/MS Analysis.

Authors:  Haiyan Lei; Jianbo Guo; Zhuo Lv; Xiaohong Zhu; Xiaofeng Xue; Liming Wu; Wei Cao
Journal:  Int J Anal Chem       Date:  2018-01-01       Impact factor: 1.885

3.  Reproducible Molecularly Imprinted Piezoelectric Sensor for Accurate and Sensitive Detection of Ractopamine in Swine and Feed Products.

Authors:  Mingfei Pan; Rui Li; Leling Xu; Jingying Yang; Xiaoyuan Cui; Shuo Wang
Journal:  Sensors (Basel)       Date:  2018-06-07       Impact factor: 3.576

4.  Effects of differing withdrawal times from ractopamine hydrochloride on residue concentrations of beef muscle, adipose tissue, rendered tallow, and large intestine.

Authors:  Haley E Davis; Ifigenia Geornaras; Valerie Lindstrom; Jacqueline M Chaparro; Mahesh N Nair; Robert J Delmore; Terry E Engle; Keith E Belk; Jessica E Prenni
Journal:  PLoS One       Date:  2020-12-02       Impact factor: 3.240

5.  A portable colorimetric chemosensing regime for ractopamine in chicken samples using μPCD decorated by silver nanoprisms.

Authors:  Hossein Navay Baghban; Mohammad Hasanzadeh; Yuqian Liu; Farzad Seidi
Journal:  RSC Adv       Date:  2022-09-08       Impact factor: 4.036

6.  Determination of ractopamine and salbutamol in pig hair by liquid chromatography tandem mass spectrometry.

Authors:  Kai-Chun Chang; Yu-Ting Chang; Chin-En Tsai
Journal:  J Food Drug Anal       Date:  2017-11-12       Impact factor: 6.157

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.