Thermoluminescent characteristics of LiF:Mg, Cu, P and CaSO4:Dy for low dose measurement.

S Del Sol Fernández1, R García-Salcedo2, J Guzmán Mendoza2, D Sánchez-Guzmán2, G Ramírez Rodríguez3, E Gaona4, T Rivera Montalvo2.   

Abstract

Thermoluminescence (TL) characteristics for LiF:Mg, Cu, P, and CaSO4:Dy under the homogeneous field of X-ray beams of diagnostic irradiation and its verification using thermoluminescence dosimetry are presented. The irradiation were performed utilizing a conventional X-ray equipment installed at the Hospital Juárez Norte of México. Different thermoluminescence characteristics of two material were studied, such as batch homogeneity, glow curve, linearity, detection threshold, reproducibility, relative sensitivity and fading. Materials were calibrated in terms of absorbed dose to the standard calibration distance and they were positioned in a generic phantom. The dose analysis, verification and comparison with the measurements obtained by the TLD-100 were performed. Results indicate that the dosimetric peak appears at 202°C and 277.5°C for LiF:Mg, Cu, P and CaSO4:Dy, respectively. TL response as a function of X-ray dose showed a linearity behavior in the very low dose range for all materials. However, the TLD-100 is not accurate for measurements below 4mGy. CaSO4:Dy is 80% more sensitive than TLD-100 and it show the lowest detection threshold, whereas LiF:Mg, Cu, P is 60% more sensitive than TLD-100. All materials showed very good repeatability. Fading for a period of one month at room temperature showed low fading LiF:Mg, Cu, P, medium and high for TLD-100 and CaSO4:Dy. The results suggest that CaSO4:Dy and LiF:Mg, Cu, P are suitable for measurements at low doses used in radiodiagnostic.
Copyright © 2016 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dosimetry; Low dose X-ray; Radiodiagnostic; Thermoluminescent materials

Year:  2016        PMID: 26922395     DOI: 10.1016/j.apradiso.2016.02.011

Source DB:  PubMed          Journal:  Appl Radiat Isot        ISSN: 0969-8043            Impact factor:   1.513


  1 in total

1.  Thermoluminescent Characteristics of GR-200, TLD-700H and TLD-100 for Low Dose Measurement: Linearity, Repeatability, Dose Rate and Photon Energy Dependence.

Authors:  Mojgan Alizadeh; Mehran Mohseni; Bagher Farhood; Akbar Aliasgharzadeh; Habiballah Moradi; Ahmad Ramazani-Moghaddam-Arani
Journal:  J Biomed Phys Eng       Date:  2022-04-01
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.