Literature DB >> 26919069

Investigating the impact of non-Newtonian blood models within a heart pump.

Mohammed G Al-Azawy1,2, A Turan1, A Revell1.   

Abstract

A detailed computational fluid dynamics (CFD) study of transient, turbulent blood flow through a positive displacement left ventricular assist device is performed. Two common models for non-Newtonian blood flow are compared to the Newtonian model to investigate their impact on predicted levels of shear rate and wall shear stress. Given that both parameters are directly relevant to the evaluation of risk from thrombus and haemolysis, there is a need to assess the sensitivity to modelling non-Newtonian flow effects within a pulsatile turbulent flow, in order to identify levels of uncertainly in CFD. To capture the effects of turbulence, the elliptic blending Reynolds stress model is used in the present study, on account of superior performance of second moment closure schemes previously identified by the present authors. The CFD configuration includes two cyclically rotating valves and a moving pusher plate to periodically vary the chamber volume. An overset mesh algorithm is used for each instance of mesh motion, and a zero gap technique was employed to ensure full valve closure. The left ventricular assist device was operated at a pumping rate of 86 BPM (beats per minute) and a systolic duration of 40% of the pumping cycle, in line with existing experimental data to which comparisons are made. The sensitivity of the variable viscosity models is investigated in terms of mean flow field, levels of turbulence and global shear rate, and a non-dimensional index is used to directly evaluate the impact of non-Newtonian effects. The clinical relevance of the results is reported along with a discussion of modelling uncertainties, observing that the turbulent kinetic energy is generally predicted to be higher in non-Newtonian flow than that observed in Newtonian flow.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  computational fluid dynamics (CFD); left ventricular assist device (LVAD); non-Newtonian flow; overset mesh; turbulence modelling

Mesh:

Year:  2016        PMID: 26919069     DOI: 10.1002/cnm.2780

Source DB:  PubMed          Journal:  Int J Numer Method Biomed Eng        ISSN: 2040-7939            Impact factor:   2.747


  7 in total

1.  Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation.

Authors:  Andrew L Cheng; Niema M Pahlevan; Derek G Rinderknecht; John C Wood; Morteza Gharib
Journal:  Eur J Mech B Fluids       Date:  2017-12-27       Impact factor: 2.183

2.  Reconstruction of carotid stenosis hemodynamics based on guidewire pressure data and computational modeling.

Authors:  Huy Dinh; Fernando Vinuela; Viktor Szeder; Kasra Khatibi; Lucido Ponce Mejia; Aichi Chien
Journal:  Med Biol Eng Comput       Date:  2022-03-31       Impact factor: 3.079

3.  Non-Newtonian blood rheology impacts left atrial stasis in patient-specific simulations.

Authors:  Alejandro Gonzalo; Manuel García-Villalba; Lorenzo Rossini; Eduardo Durán; Davis Vigneault; Pablo Martínez-Legazpi; Oscar Flores; Javier Bermejo; Elliot McVeigh; Andrew M Kahn; Juan C Del Alamo
Journal:  Int J Numer Method Biomed Eng       Date:  2022-04-07       Impact factor: 2.648

4.  A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow.

Authors:  Andrew L Cheng; Choo Phei Wee; Niema M Pahlevan; John C Wood
Journal:  Am J Physiol Heart Circ Physiol       Date:  2019-10-04       Impact factor: 4.733

5.  Turbulent Flow Promotes Cleavage of VWF (von Willebrand Factor) by ADAMTS13 (A Disintegrin and Metalloproteinase With a Thrombospondin Type-1 Motif, Member 13).

Authors:  Maria Bortot; Katrina Ashworth; Alireza Sharifi; Faye Walker; Nathan C Crawford; Keith B Neeves; David Bark; Jorge Di Paola
Journal:  Arterioscler Thromb Vasc Biol       Date:  2019-07-11       Impact factor: 10.514

Review 6.  Innovative Modeling Techniques and 3D Printing in Patients with Left Ventricular Assist Devices: A Bridge from Bench to Clinical Practice.

Authors:  Rishi Thaker; Raquel Araujo-Gutierrez; Hernan G Marcos-Abdala; Tanushree Agrawal; Nadia Fida; Mahwash Kassi
Journal:  J Clin Med       Date:  2019-05-09       Impact factor: 4.241

7.  Tunable Blood Shunt for Neonates With Complex Congenital Heart Defects.

Authors:  Ellen Garven; Christopher B Rodell; Kristen Shema; Krianthan Govender; Samantha E Cassel; Bryan Ferrick; Gabriella Kupsho; Ethan Kung; Kara L Spiller; Randy Stevens; Amy L Throckmorton
Journal:  Front Bioeng Biotechnol       Date:  2022-01-13
  7 in total