Literature DB >> 26916568

Comparison of two different drug-coated balloons for the treatment of in-stent restenosis: A long-term single-centre experience.

Javier Benezet1, Antonio Agarrado2, Alejandro Gutiérrez-Barrios2, Dolores Ruiz-Fernandez2, Ana Del Río2, Dolores Cañadas2.   

Abstract

OBJECTIVES: We aim to evaluate the long-term efficacy of two different paclitaxel-coated balloons (PCBs) for the treatment of coronary in-stent restenosis (ISR).
METHODS: Between February 2011 and February 2012, all consecutive patients with ISR lesions treated with the SeQuent® Please (B. Braun, Melsungen, Germany) PCB or with the DIOR® (Eurocor GmbH, Bonn, Germany) PCB at our institution were prospectively included and followed up for 36months by clinical observation. The primary endpoint was the clinically driven target lesion revascularization (TLR) rate at 36months.
RESULTS: 65 patients with 74 ISR lesions were included. 43 ISR lesions were treated with the SeQuent® Please PCB and 31 with the DIOR® PCB. Baseline clinical, lesion characteristics and procedural data did not significantly differ between the groups. The TLR rate was significantly lower in patients treated with the SeQuent® Please PCB compared with the DIOR® PCB (4.7% vs. 22. 6%, p=0.03) at 36months.
CONCLUSIONS: This registry suggests that there are differences in terms of TLR between two clinically available PCBs. The SeQuent® Please PCB demonstrated lower TLR rate compared to the DIOR® PCB at 36months follow up.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Angioplasty; Drug-coated balloons; In stent restenosis; Target lesion revascularization

Mesh:

Substances:

Year:  2016        PMID: 26916568     DOI: 10.1016/j.carrev.2016.01.012

Source DB:  PubMed          Journal:  Cardiovasc Revasc Med        ISSN: 1878-0938


  2 in total

1.  Prevention of neointimal formation after angioplasty using tetramethylpyrazine-coated balloon catheters in a rabbit iliac artery model.

Authors:  Lijuan Chen; Si Pang; Chunshu Hao; Aiming Xie; Kongbo Zhu; Yanru He; Xiaoguo Zhang; Wenbing Lu; Genshan Ma; Zhong Chen
Journal:  Cardiovasc Diagn Ther       Date:  2019-10

2.  Linear Micro-patterned Drug Eluting Balloon (LMDEB) for Enhanced Endovascular Drug Delivery.

Authors:  KangJu Lee; Seul Gee Lee; Ilkwang Jang; Seung Hyun Park; Dasom Yang; Il Ho Seo; Sung-Kyung Bong; Duk Hwan An; Min Kwon Lee; In Kwon Jung; Yong Hoon Jang; Jung Sun Kim; WonHyoung Ryu
Journal:  Sci Rep       Date:  2018-03-05       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.