Literature DB >> 26901015

Dual-Energy CT-Based Differentiation of Benign Posttreatment Changes From Primary or Recurrent Malignancy of the Head and Neck: Comparison of Spectral Hounsfield Units at 40 and 70 keV and Iodine Concentration.

Hideomi Yamauchi1, Mark Buehler2, Mitchell M Goodsitt3, Nahid Keshavarzi4, Ashok Srinivasan5.   

Abstract

OBJECTIVE: The goals of our study were to evaluate dual-energy CT (DECT) differences between benign posttreatment changes and primary or recurrent head and neck malignancies in terms of spectral Hounsfield units for virtual monochromatic series at 40 keV and iodine concentration and compare their utility with that of spectral Hounsfield units at 70 keV.
MATERIALS AND METHODS: A retrospective review of patients with a history of head and neck malignancy evaluated with DECT of the neck from November 2012 through December 2014 revealed 16 patients with benign posttreatment changes and 24 with malignancies (17 primary tumors and seven recurrent tumors). One reader placed ROIs within benign posttreatment changes or malignant tumors in each patient to generate spectral Hounsfield units at 40 keV, iodine concentration, and spectral Hounsfield units at 70 keV, and the Wilcoxon rank sum test was used to evaluate the differences between the two cohorts. ROC curves were also generated, and AUC and partial AUC were calculated at the three following specificities: 75%, 80%, and 90%.
RESULTS: Malignant tissues were significantly different from benign posttreatment changes in spectral Hounsfield units at 40 keV (p < 0.0001), iodine concentration (p < 0.0001), and spectral Hounsfield units at 70 keV (p = 0.0001). The AUCs were 0.949, 0.943, and 0.858 for spectral Hounsfield units at 40 keV, iodine concentration, and spectral Hounsfield units at 70 keV, respectively. Both spectral Hounsfield units at 40 keV and iodine concentration had statistically higher partial AUCs than spectral Hounsfield units at 70 keV at 90% specificity (p = 0.0133 and 0.0063, respectively) but were not significantly different from each other.
CONCLUSION: DECT-derived spectral Hounsfield units at 40 keV and iodine concentration may be superior to spectral Hounsfield units at 70 keV, which is similar to MDCT, in differentiating benign posttreatment changes from primary or recurrent head and neck malignancies.

Entities:  

Keywords:  dual-energy CT; head and neck malignancy; spectral Hounsfield units

Mesh:

Substances:

Year:  2016        PMID: 26901015     DOI: 10.2214/AJR.15.14896

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Benefit of dual-energy CT iodine overlay technique for T1-hyperintense brain lesion.

Authors:  Younghen Lee; Hyung Suk Seo; Bo-Kyung Je; Sang-Dae Kim; Hwa Eun Oh
Journal:  Neurology       Date:  2017-09-26       Impact factor: 9.910

Review 2.  Extra-abdominal dual-energy CT applications: a comprehensive overview.

Authors:  Giuseppe Cicero; Giorgio Ascenti; Moritz H Albrecht; Alfredo Blandino; Marco Cavallaro; Tommaso D'Angelo; Maria Ludovica Carerj; Thomas J Vogl; Silvio Mazziotti
Journal:  Radiol Med       Date:  2020-01-10       Impact factor: 3.469

3.  Dual-energy CT in differentiating benign sinonasal lesions from malignant ones: comparison with simulated single-energy CT, conventional MRI, and DWI.

Authors:  Peng Wang; Zuohua Tang; Zebin Xiao; Rujian Hong; Rong Wang; Yuzhe Wang; Yang Zhan
Journal:  Eur Radiol       Date:  2021-08-24       Impact factor: 5.315

4.  Mastication in maxillectomy patients: A comparison between reconstructed maxillae and implant supported obturators: A cross-sectional study.

Authors:  Doke J M Buurman; Caroline M Speksnijder; Reilly J de Groot; Peter Kessler; Jana M Rieger
Journal:  J Oral Rehabil       Date:  2020-07-13       Impact factor: 3.837

5.  Dual-Layer Spectral CT Imaging of Upper Aerodigestive Tract Cancer: Analysis of Spectral Imaging Parameters and Impact on Tumor Staging.

Authors:  C C-T Hsu; C Jeavon; I Fomin; L Du; C Buchan; T W Watkins; Y Nae; N M Parry; R I Aviv
Journal:  AJNR Am J Neuroradiol       Date:  2021-07-29       Impact factor: 4.966

Review 6.  Dual-Energy CT in Head and Neck Imaging.

Authors:  Elise D Roele; Veronique C M L Timmer; Lauretta A A Vaassen; Anna M J L van Kroonenburgh; A A Postma
Journal:  Curr Radiol Rep       Date:  2017-03-29

7.  Therapy Effects of Advanced Hypopharyngeal and Laryngeal Squamous Cell Carcinoma: Evaluated using Dual-Energy CT Quantitative Parameters.

Authors:  Liang Yang; Dehong Luo; Junlin Yi; Lin Li; Yanfeng Zhao; Meng Lin; Wei Guo; Lei Hu; Chunwu Zhou
Journal:  Sci Rep       Date:  2018-06-13       Impact factor: 4.379

8.  Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study.

Authors:  Vanja Harsaker; Kristin Jensen; Hilde Kjernlie Andersen; Anne Catrine Martinsen
Journal:  Eur Radiol Exp       Date:  2021-06-23
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.