Hypoxic events and concomitant factors in preterm infants on non-invasive ventilation.

Omid Sadeghi Fathabadi1, Timothy Gale2, Kevin Wheeler3,4, Gemma Plottier3, Louise S Owen4,5,6, J C Olivier2, Peter A Dargaville3,7.   

Abstract

Automated control of inspired oxygen for newborn infants is an emerging technology, currently limited by reliance on a single input signal (oxygen saturation, SpO2). This is while other signals that may herald the onset of hypoxic events or identify spurious hypoxia are not usually utilised. We wished to assess the frequency of apnoea, loss of circuit pressure and/or motion artefact in proximity to hypoxic events in preterm infants on non-invasive ventilation. Hypoxic events (SpO2 < 80 %) were identified using a previously acquired dataset obtained from preterm infants receiving non-invasive ventilation. Events with concomitant apnoea, loss of circuit pressure or oximetry motion artefact were annotated, and the frequency of each of these factors was determined. The effect of duration and timing of apnoea on the characteristics of the associated hypoxic events was studied. Among 1224 hypoxic events, 555 (45 %) were accompanied by apnoea, 31 (2.5 %) by loss of circuit pressure and 696 (57 %) by motion artefact, while for 224 (18 %) there were no concomitant factors identified. Respiratory pauses of longer duration (>15 s) preceding hypoxic events, were associated with a relatively slow decline in SpO2 and more prolonged hypoxia compared to shorter pauses. Hypoxic events are frequently accompanied by respiratory pauses and/or motion artefact. Real-time monitoring and input of respiratory waveform may thus improve the function of automated oxygen controllers, allowing pre-emptive responses to respiratory pauses. Furthermore, use of motion-resistant oximeters and plethysmographic waveform assessment procedures will help to optimise feedback control of inspired oxygen delivery.

Entities:  

Keywords:  Apnoea; Automated oxygen control; Continuous positive airway pressure; Motion artefact; Preterm infants; Pulse oximetry

Mesh:

Substances:

Year:  2016        PMID: 26897033     DOI: 10.1007/s10877-016-9847-3

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  29 in total

1.  Adaptive control of inspired oxygen delivery to the neonate.

Authors:  V K Bhutani; J C Taube; M J Antunes; M Delivoria-Papadopoulos
Journal:  Pediatr Pulmonol       Date:  1992-10

2.  Multicenter crossover study of automated control of inspired oxygen in ventilated preterm infants.

Authors:  Nelson Claure; Eduardo Bancalari; Carmen D'Ugard; Leif Nelin; Melanie Stein; Rangasamy Ramanathan; Richard Hernandez; Steven M Donn; Michael Becker; Thomas Bachman
Journal:  Pediatrics       Date:  2010-12-27       Impact factor: 7.124

3.  Pulse oximetry in very low birth weight infants: can oxygen saturation be maintained in the desired range?

Authors:  A R Laptook; W Salhab; J Allen; S Saha; M Walsh
Journal:  J Perinatol       Date:  2006-06       Impact factor: 2.521

4.  Hyperoxia-derived lung damage in preterm infants.

Authors:  Vineet Bhandari
Journal:  Semin Fetal Neonatal Med       Date:  2010-04-28       Impact factor: 3.926

5.  New technique for servo-control of arterial oxygen tension in preterm infants.

Authors:  I R Beddis; P Collins; N M Levy; S Godfrey; M Silverman
Journal:  Arch Dis Child       Date:  1979-04       Impact factor: 3.791

6.  Detection of movement artifact in recorded pulse oximeter saturation.

Authors:  C F Poets; V A Stebbens
Journal:  Eur J Pediatr       Date:  1997-10       Impact factor: 3.183

7.  Effects of nasal continuous positive airway pressure (NCPAP) on breathing pattern in spontaneously breathing premature newborn infants.

Authors:  A Elgellab; Y Riou; A Abbazine; P Truffert; R Matran; P Lequien; L Storme
Journal:  Intensive Care Med       Date:  2001-10-31       Impact factor: 17.440

8.  Patterns of oxygenation during periodic breathing in preterm infants.

Authors:  C F Poets; D P Southall
Journal:  Early Hum Dev       Date:  1991-07       Impact factor: 2.079

9.  Target ranges of oxygen saturation in extremely preterm infants.

Authors:  Waldemar A Carlo; Neil N Finer; Michele C Walsh; Wade Rich; Marie G Gantz; Abbot R Laptook; Bradley A Yoder; Roger G Faix; Abhik Das; W Kenneth Poole; Kurt Schibler; Nancy S Newman; Namasivayam Ambalavanan; Ivan D Frantz; Anthony J Piazza; Pablo J Sánchez; Brenda H Morris; Nirupama Laroia; Dale L Phelps; Brenda B Poindexter; C Michael Cotten; Krisa P Van Meurs; Shahnaz Duara; Vivek Narendran; Beena G Sood; T Michael O'Shea; Edward F Bell; Richard A Ehrenkranz; Kristi L Watterberg; Rosemary D Higgins
Journal:  N Engl J Med       Date:  2010-05-16       Impact factor: 91.245

10.  A randomised controlled trial of an automated oxygen delivery algorithm for preterm neonates receiving supplemental oxygen without mechanical ventilation.

Authors:  James Zapata; John Jairo Gómez; Robinson Araque Campo; Alejandro Matiz Rubio; Augusto Sola
Journal:  Acta Paediatr       Date:  2014-08-01       Impact factor: 2.299

View more
  1 in total

Review 1.  Journal of Clinical Monitoring and Computing 2017 end of year summary: respiration.

Authors:  D S Karbing; G Perchiazzi; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2018-02-26       Impact factor: 2.502

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.