Literature DB >> 26895785

Biomechanical Evaluation of Suture Anchor Versus Transosseous Tunnel Quadriceps Tendon Repair Techniques.

Seth L Sherman1, Marilyn E Copeland2, Jeffrey L Milles3, David A Flood3, Ferris M Pfeiffer4.   

Abstract

PURPOSE: To evaluate the biomechanical fixation strength of suture anchor and transosseous tunnel repair of the quadriceps tendon in a standardized cadaveric repair model.
METHODS: Twelve "patella-only" specimens were used. Dual-energy X-ray absorptiometry measurement was performed to ensure equal bone quality amongst groups. Specimens were randomly assigned to either a suture anchor repair of quadriceps tendon group (n = 6) or a transosseous tunnel repair group (n = 6). Suture type and repair configuration were equivalent. After the respective procedures were performed, each patella was mounted into a gripping jig. Tensile load was applied at a rate of 0.1 mm/s up to 100 N after which cyclic loading was applied at a rate of 1 Hz between magnitudes of 50 to 150 N, 50 to 200 N, 50 to 250 N, and tensile load at a rate of 0.1 mm/s until failure. Outcome measures included load to failure, displacement at 1st 100 N load, and displacement after each 10th cycle of loading.
RESULTS: The measured cyclic displacement to the first 100 N, 50 to 150 N, 50 to 200 N, and 50 to 250 N was significantly less for suture anchors than transosseous tunnels. There was no statistically significant difference in ultimate load to failure between the 2 groups (P = .40). Failure mode for all suture anchors except one was through the soft tissue. Failure mode for all transosseous specimens but one was pulling the repair through the transosseous tunnel.
CONCLUSIONS: Suture anchor quadriceps tendon repairs had significantly decreased gapping during cyclic loading, but no statistically significant difference in ultimate load to failure when compared with transosseous tunnel repairs. Although suture anchor quadriceps tendon repair appears to be a biomechanically superior construct, a clinical study is needed to confirm this technique as a viable alternative to gold standard transosseous techniques. CLINICAL RELEVANCE: Although in vivo studies are needed, these results support the suture anchor technique as a viable alternative to transosseous repair of the quadriceps tendon.
Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 26895785     DOI: 10.1016/j.arthro.2015.11.038

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  12 in total

Review 1.  Extensor Carpi Radialis Longus Tenodesis Using a Biotenodesis Screw for Treatment of Symptomatic Geissler 2 Scapholunate Dissociation.

Authors:  Andrew Stone; Zuhaib Shahid; Sujit Agarwal; Tanaya Sarkhel
Journal:  J Hand Microsurg       Date:  2019-05-19

2.  Risk Factors Associated with Dislocation after Bipolar Hemiarthroplasty in Elderly Patients with Femoral Neck Fracture.

Authors:  Yeesuk Kim; Joon-Kuk Kim; Il-Han Joo; Kyu-Tae Hwang; Young-Ho Kim
Journal:  Hip Pelvis       Date:  2016-06-30

3.  Bilateral Quadriceps Tendon Repair with Suture Anchors: Case Series.

Authors:  Jason E Tucker; Christopher R Jones
Journal:  Perm J       Date:  2020

4.  Lucent Patellar Lesions: A Pictorial Review.

Authors:  Ziang Lu; Kira Chow; Benjamin Levine; Kambiz Motamedi; Joshua Leeman
Journal:  J Radiol Case Rep       Date:  2022-06-30

5.  Biomechanical Analysis of Patellar Tendon Repair With Knotless Suture Anchor Tape Versus Transosseous Suture.

Authors:  Patrick A Massey; Mitchell Myers; Kaylan McClary; Jimmy Brown; R Shane Barton; Giovanni F Solitro
Journal:  Orthop J Sports Med       Date:  2020-10-02

6.  Simultaneous Ipsilateral Quadriceps and Triceps Tendon Rupture in a Patient with End-Stage Renal Failure.

Authors:  Kevin Moerenhout; Georgios Gkagkalis; Benoit Benoit; Georges Yves Laflamme
Journal:  Case Rep Orthop       Date:  2018-08-05

7.  Clinical and Biomechanical Outcomes following Knee Extensor Mechanism Reconstruction.

Authors:  Berkcan Akpinar; Samuel Baron; Michael J Alaia; Laith M Jazrawi
Journal:  Arthrosc Sports Med Rehabil       Date:  2020-09-02

8.  Open Repair of Quadriceps Tendon With Suture Anchors and Semitendinosus Tendon Allograft Augmentation.

Authors:  Jorge Chahla; Nicholas N DePhillipo; Mark E Cinque; Nicholas I Kennedy; George F Lebus; Filippo Familiari; Gilbert Moatshe; Robert F LaPrade
Journal:  Arthrosc Tech       Date:  2017-11-06

9.  Clinical outcomes after treatment of quadriceps tendon ruptures show equal results independent of suture anchor or transosseus repair technique used - A pilot study.

Authors:  Stefan Plesser; Mohammad Keilani; Gyoergy Vekszler; Timothy Hasenoehrl; Stefano Palma; Martin Reschl; Richard Crevenna; Stefan Hajdu; Harald Kurt Widhalm
Journal:  PLoS One       Date:  2018-03-19       Impact factor: 3.240

10.  Adjustable Cortical Fixation Device for Quadriceps Tendon Repair: A Cadaveric Biomechanical Study.

Authors:  Heath P Gould; William R Rate; Pooyan Abbasi; Katherine L Mistretta; Jason W Hammond
Journal:  Orthop J Sports Med       Date:  2021-01-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.