Literature DB >> 2689341

Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures.

C L Cheng1, S P Chow, W K Pun, J C Leong.   

Abstract

Thirty-eight patients with unstable trochanteric fractures of the femur were treated with Dimon-Hughston displacement osteotomy and cement augmentation at the fracture site. Of these patients 76 per cent had excellent and good results after an average follow-up of 3.7 years (range 2-5 years). Late complications occurred in six hips. These included non-union at the trochanteric fracture, protruding pin, partial destruction of the femoral head, subcapital fracture of the femoral neck, and avascular necrosis of the femoral head. All complications occurred late (1 year after surgery) and were related to inappropriate placement and excessive amount of cement, together with inadequate new bone formation. The augmentation of cement provided early stability for early mobilization in these elderly patients. However, when improperly used, late complications can occur.

Entities:  

Mesh:

Year:  1989        PMID: 2689341     DOI: 10.1016/0020-1383(89)90082-x

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  7 in total

1.  The effect of cement placement on augmentation of the osteoporotic proximal femur.

Authors:  Edward G Sutter; Simon J Wall; Simon C Mears; Stephen M Belkoff
Journal:  Geriatr Orthop Surg Rehabil       Date:  2010-09

2.  A biomechanical evaluation of femoroplasty under simulated fall conditions.

Authors:  Edward G Sutter; Simon C Mears; Stephen M Belkoff
Journal:  J Orthop Trauma       Date:  2010-02       Impact factor: 2.512

3.  Indications for cement augmentation in fixation of geriatric intertrochanteric femur fractures: a systematic review of evidence.

Authors:  L Henry Goodnough; Harsh Wadhwa; Seth S Tigchelaar; Malcolm R DeBaun; Michael J Chen; Matt L Graves; Michael J Gardner
Journal:  Arch Orthop Trauma Surg       Date:  2021-04-07       Impact factor: 2.928

4.  Measurement of Tip Apex Distance and Migration of Lag Screws and Novel Blade Screw Used for the Fixation of Intertrochanteric Fractures.

Authors:  Jesse Chieh-Szu Yang; Hsin-Chang Chen; Yu-Shu Lai; Cheng-Kung Cheng
Journal:  PLoS One       Date:  2017-01-13       Impact factor: 3.240

5.  The effects of bone-substitute augmentation on treatment of osteoporotic intertrochanteric fractures.

Authors:  Fu-Chun Chang; Pao-Yao Chuang; Ching-Yu Lee; Chien-Yin Lee; Ying-Chao Chou; Tsan-Wen Huang; Kuo-Chin Huang; Hsin-Nung Shih; Mel S Lee
Journal:  Biomed J       Date:  2020-05-23       Impact factor: 7.892

6.  Outcomes of osteoporotic trochanteric fractures treated with cement-augmented dynamic hip screw.

Authors:  Rakesh Kumar Gupta; Vinay Gupta; Navdeep Gupta
Journal:  Indian J Orthop       Date:  2012-11       Impact factor: 1.251

7.  Long-Term Response to a Bioactive Biphasic Biomaterial in the Femoral Neck of Osteoporotic Rats.

Authors:  Deepak Bushan Raina; Aurimas Širka; Irfan Qayoom; Arun Kumar Teotia; Yang Liu; Sarunas Tarasevicius; Kathleen Elizabeth Tanner; Hanna Isaksson; Ashok Kumar; Magnus Tägil; Lars Lidgren
Journal:  Tissue Eng Part A       Date:  2020-10       Impact factor: 3.845

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.