Literature DB >> 26892945

In vivo comparison of tantalum, tungsten, and bismuth enteric contrast agents to complement intravenous iodine for double-contrast dual-energy CT of the bowel.

Samira Rathnayake1, John Mongan1, Andrew S Torres2, Robert Colborn2, Dong-Wei Gao1, Benjamin M Yeh1, Yanjun Fu1.   

Abstract

To assess the ability of dual-energy CT (DECT) to separate intravenous contrast of bowel wall from intraluminal contrast, we scanned 16 rabbits on a clinical DECT scanner: n = 3 using only iodinated intravenous contrast, and n = 13 double-contrast enhanced scans using iodinated intravenous contrast and experimental enteric non-iodinated contrast agents in the bowel lumen (five bismuth, four tungsten, and four tantalum based). Representative image pairs from conventional CT images and DECT iodine density maps of small bowel (116 pairs from 232 images) were viewed by four abdominal imaging attending radiologists to independently score each comparison pair on a visual analog scale (-100 to +100%) for (1) preference in small bowel wall visualization and (2) preference in completeness of intraluminal enteric contrast subtraction. Median small bowel wall visualization was scored 39 and 42 percentage points (95% CI 30-44% and 36-45%, both p < 0.001) higher for double-contrast DECT than for conventional CT with enteric tungsten and tantalum contrast, respectively. Median small bowel wall visualization for double-contrast DECT was scored 29 and 35 percentage points (95% CI 20-35% and 33-39%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Median completeness of intraluminal enteric contrast subtraction in double-contrast DECT iodine density maps was scored 28 and 29 percentage points (95% CI 15-31% and 28-33%, both p < 0.001) higher with enteric tungsten and tantalum, respectively, than with bismuth contrast. Results suggest that in vivo double-contrast DECT with iodinated intravenous and either tantalum- or tungsten-based enteric contrast provides better visualization of small bowel than conventional CT.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  CT enterography; bismuth; contrast agent; dual-energy CT; small bowel; tantalum; tungsten

Mesh:

Substances:

Year:  2016        PMID: 26892945      PMCID: PMC4969129          DOI: 10.1002/cmmi.1687

Source DB:  PubMed          Journal:  Contrast Media Mol Imaging        ISSN: 1555-4309            Impact factor:   3.161


  28 in total

1.  Synthesis, characterization, and computed tomography imaging of a tantalum oxide nanoparticle imaging agent.

Authors:  Peter J Bonitatibus; Andrew S Torres; Gregory D Goddard; Paul F FitzGerald; Amit M Kulkarni
Journal:  Chem Commun (Camb)       Date:  2010-10-25       Impact factor: 6.222

2.  Computed tomography in color: NanoK-enhanced spectral CT molecular imaging.

Authors:  Dipanjan Pan; Ewald Roessl; Jens-Peter Schlomka; Shelton D Caruthers; Angana Senpan; Mike J Scott; John S Allen; Huiying Zhang; Grace Hu; Patrick J Gaffney; Eric T Choi; Volker Rasche; Samuel A Wickline; Roland Proksa; Gregory M Lanza
Journal:  Angew Chem Int Ed Engl       Date:  2010-12-10       Impact factor: 15.336

3.  Large-scale synthesis of bioinert tantalum oxide nanoparticles for X-ray computed tomography imaging and bimodal image-guided sentinel lymph node mapping.

Authors:  Myoung Hwan Oh; Nohyun Lee; Hyoungsu Kim; Seung Pyo Park; Yuanzhe Piao; Jisoo Lee; Samuel Woojoo Jun; Woo Kyung Moon; Seung Hong Choi; Taeghwan Hyeon
Journal:  J Am Chem Soc       Date:  2011-03-23       Impact factor: 15.419

Review 4.  A review of tungsten: from environmental obscurity to scrutiny.

Authors:  A Koutsospyros; W Braida; C Christodoulatos; D Dermatas; N Strigul
Journal:  J Hazard Mater       Date:  2005-12-15       Impact factor: 10.588

5.  Small bowel involvement in Crohn's disease: a prospective comparison of wireless capsule endoscopy and computed tomography enteroclysis.

Authors:  W A Voderholzer; J Beinhoelzl; P Rogalla; S Murrer; G Schachschal; H Lochs; M-A Ortner
Journal:  Gut       Date:  2005-03       Impact factor: 23.059

6.  A feasibility study of splenohepatography with tantalum metal and tantalum pentoxide.

Authors:  C Gianturco; B Ruskin; F R Steggerda; T Takeuchi
Journal:  Radiology       Date:  1972-01       Impact factor: 11.105

7.  An X-ray computed tomography imaging agent based on long-circulating bismuth sulphide nanoparticles.

Authors:  Oded Rabin; J Manuel Perez; Jan Grimm; Gregory Wojtkiewicz; Ralph Weissleder
Journal:  Nat Mater       Date:  2006-01-29       Impact factor: 43.841

8.  Biological performance of a size-fractionated core-shell tantalum oxide nanoparticle x-ray contrast agent.

Authors:  Andrew S Torres; Peter J Bonitatibus; Robert E Colborn; Gregory D Goddard; Paul F FitzGerald; Brian D Lee; Michael E Marino
Journal:  Invest Radiol       Date:  2012-10       Impact factor: 6.016

9.  CT evaluation of Crohn's disease: effect on patient management.

Authors:  E K Fishman; E J Wolf; B Jones; T M Bayless; S S Siegelman
Journal:  AJR Am J Roentgenol       Date:  1987-03       Impact factor: 3.959

10.  Detecting vascular biosignatures with a colloidal, radio-opaque polymeric nanoparticle.

Authors:  Dipanjan Pan; Todd A Williams; Angana Senpan; John S Allen; Mike J Scott; Patrick J Gaffney; Samuel A Wickline; Gregory M Lanza
Journal:  J Am Chem Soc       Date:  2009-10-28       Impact factor: 15.419

View more
  11 in total

1.  Quantitative accuracy and dose efficiency of dual-contrast imaging using dual-energy CT: a phantom study.

Authors:  Liqiang Ren; Kishore Rajendran; Cynthia H McCollough; Lifeng Yu
Journal:  Med Phys       Date:  2019-12-10       Impact factor: 4.071

2.  An Image-Domain Contrast Material Extraction Method for Dual-Energy Computed Tomography.

Authors:  Jack W Lambert; Yuxin Sun; Robert G Gould; Michael A Ohliger; Zhixi Li; Benjamin M Yeh
Journal:  Invest Radiol       Date:  2017-04       Impact factor: 6.016

3.  Improved Calcium Scoring at Dual-Energy Computed Tomography Angiography Using a High-Z Contrast Element and Novel Material Separation Technique.

Authors:  Jack W Lambert; Yuxin Sun; Karen G Ordovas; Robert G Gould; Sizhe Wang; Benjamin M Yeh
Journal:  J Comput Assist Tomogr       Date:  2018 May/Jun       Impact factor: 1.826

4.  Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo.

Authors:  Salim Si-Mohamed; David P Cormode; Daniel Bar-Ness; Monica Sigovan; Pratap C Naha; Jean-Baptiste Langlois; Lara Chalabreysse; Philippe Coulon; Ira Blevis; Ewald Roessl; Klaus Erhard; Loic Boussel; Philippe Douek
Journal:  Nanoscale       Date:  2017-11-30       Impact factor: 7.790

Review 5.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

6.  An Intravascular Tantalum Oxide-based CT Contrast Agent: Preclinical Evaluation Emulating Overweight and Obese Patient Size.

Authors:  Jack W Lambert; Yuxin Sun; Carol Stillson; Zhixi Li; Rahi Kumar; Sizhe Wang; Paul F FitzGerald; Peter J Bonitatibus; Robert E Colborn; Jeannette C Roberts; Peter M Edic; Michael Marino; Benjamin M Yeh
Journal:  Radiology       Date:  2018-07-03       Impact factor: 11.105

7.  Improved Peritoneal Cavity and Abdominal Organ Imaging Using a Biphasic Contrast Agent Protocol and Spectral Photon Counting Computed Tomography K-Edge Imaging.

Authors:  Salim Si-Mohamed; Arnaud Thivolet; Pierre-Emmanuel Bonnot; Daniel Bar-Ness; Vahan Képénékian; David P Cormode; Philippe Douek; Pascal Rousset
Journal:  Invest Radiol       Date:  2018-10       Impact factor: 6.016

8.  Multicolour imaging with spectral photon-counting CT: a phantom study.

Authors:  Salim Si-Mohamed; Daniel Bar-Ness; Monica Sigovan; Valérie Tatard-Leitman; David P Cormode; Pratap C Naha; Philippe Coulon; Lucie Rascle; Ewald Roessl; Michal Rokni; Ami Altman; Yoad Yagil; Loic Boussel; Philippe Douek
Journal:  Eur Radiol Exp       Date:  2018-10-17

Review 9.  Application of Radiosensitizers in Cancer Radiotherapy.

Authors:  Liuyun Gong; Yujie Zhang; Chengcheng Liu; Mingzhen Zhang; Suxia Han
Journal:  Int J Nanomedicine       Date:  2021-02-12

Review 10.  Dual-energy CT of acute bowel ischemia.

Authors:  Markus M Obmann; Gopal Punjabi; Verena C Obmann; Daniel T Boll; Tobias Heye; Matthias R Benz; Benjamin M Yeh
Journal:  Abdom Radiol (NY)       Date:  2021-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.