Literature DB >> 26892804

Point-of-care coagulometry in prehospital emergency patients--are international normalized ratios useful?

Manuel F Struck1, Peter Hilbert-Carius2.   

Abstract

Entities:  

Mesh:

Year:  2016        PMID: 26892804      PMCID: PMC4759783          DOI: 10.1186/s13049-015-0186-z

Source DB:  PubMed          Journal:  Scand J Trauma Resusc Emerg Med        ISSN: 1757-7241            Impact factor:   2.953


× No keyword cloud information.

Commentary

With great interest we read the recent article of Beynon et al. [1]. The authors aimed to assess the validity of a point-of-care (POC) coagulometer measuring international normalized ratios (INR) utilized in a prehospital setting. Indeed, there is a great potential for POC tests in emergency patients and only few studies have been conducted. Although the authors highlighted limitations of their own study and the relevance of INR itself, we feel that the study has further important limitations seriously restricting the implications. Most important, the validity of a test is defined as the degree to which an instrument measures the construct it purports to measure, and this objective was not defined [2]. A coagulopathy in general does not exist and prothrombin times (PT) are not established tests for a coagulopathy in general. Since INR was developed only to monitor long-term treatment of vitamin K antagonists (VKA), effects of other coagulation conditions, i.e., antiplatelet treatment, thrombocytopenia, hyperfibrinolysis or inherited platelet disorders can not be detected by INR measurements. A possible application for POC coagulometers in the prehospital setting is to assess INR in emergency patients treated with VKA. However, this issue was extensively studied in large (non-emergency) cohorts involving appropriate sample sizes and valid study designs [3, 4]. In the past decades, VKA accounted for the most prescribed anticoagulants worldwide in patients with atrial fibrillation and deep vein thrombosis. This practice is now under considerable change since non-vitamin K antagonist oral anticoagulants (NOAC) are available [5]. The dimension of this change is currently not predictable but it might replace common practice patterns in the future. An interesting objective would be to observe the sensitivity of POC coagulometers for detecting these direct oral anticoagulants, i.e., rivaroxaban, apixaban, edoxaban or dabigatran [6]. Diagnosis of NOAC activity is not reflected by standard coagulation parameters (PT using INR or Quick’s value, and partial thromboplastin time (PTT), respectively). Furthermore, patients under NOAC who sustain injuries and/or surgery are exposed to relevant risks of prolonged bleeding without abnormal standard coagulation parameters [6, 7]. This may potentially affect clinical practice in emergency medicine and attention of general practitioners. We agree with the authors that the implementation of POC coagulometers might be feasible in pre-hospital emergency settings but the search for an easily available parameter enlightening the complexities of the entire coagulation system continues.
  7 in total

Review 1.  Precision and accuracy of point-of-care testing coagulometers used for self-testing and self-management of oral anticoagulation therapy.

Authors:  T D Christensen; T B Larsen
Journal:  J Thromb Haemost       Date:  2012-02       Impact factor: 5.824

2.  Point-of-Care Testing of Coagulation in Patients Treated With Non-Vitamin K Antagonist Oral Anticoagulants.

Authors:  Matthias Ebner; Andreas Peter; Charlotte Spencer; Florian Härtig; Ingvild Birschmann; Joachim Kuhn; Martin Wolf; Natalie Winter; Francesca Russo; Christine S Zuern; Gunnar Blumenstock; Ulf Ziemann; Sven Poli
Journal:  Stroke       Date:  2015-08-13       Impact factor: 7.914

3.  The COSMIN study reached international consensus on taxonomy, terminology, and definitions of measurement properties for health-related patient-reported outcomes.

Authors:  Lidwine B Mokkink; Caroline B Terwee; Donald L Patrick; Jordi Alonso; Paul W Stratford; Dirk L Knol; Lex M Bouter; Henrica C W de Vet
Journal:  J Clin Epidemiol       Date:  2010-07       Impact factor: 6.437

4.  Practical management of bleeding in patients receiving non-vitamin K antagonist oral anticoagulants.

Authors:  Jeffrey I Weitz; Charles V Pollack
Journal:  Thromb Haemost       Date:  2015-07-09       Impact factor: 5.249

5.  Accuracy of the point-of-care coagulometer CoaguChek XS in the hands of patients.

Authors:  M Nagler; P Raddatz-Müller; P Schmid; L M Bachmann; W A Wuillemin
Journal:  J Thromb Haemost       Date:  2013-01       Impact factor: 5.824

6.  National Trends in Ambulatory Oral Anticoagulant Use.

Authors:  Geoffrey D Barnes; Eleanor Lucas; G Caleb Alexander; Zachary D Goldberger
Journal:  Am J Med       Date:  2015-07-02       Impact factor: 4.965

7.  Point of care coagulometry in prehospital emergency care: an observational study.

Authors:  Christopher Beynon; Angelina G Erk; Anna Potzy; Stefan Mohr; Erik Popp
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-08-12       Impact factor: 2.953

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.