Validation of micro-computed tomography for occlusal caries detection: an in vitro study.

Gökhan Özkan1, Aydan Kanli2, Nurdan Meserret Başeren3, Umut Arslan4, İlkan Tatar5.   

Abstract

Conventional methods of caries detection, including the gold standard of histological examination, have certain disadvantages that must be addressed prior to validating any other diagnostic technique-current or new. Here we evaluated the validity of micro-computed tomography (micro-CT) as an alternative gold-standard technique for caries detection. Sixty teeth with suspected occlusal caries were chosen from a pool of teeth extracted for orthodontic, periodontal, or surgical reasons. Identical reference points were marked on photographs taken for teeth and were used to evaluate each method. Dimensions of caries were assessed by two calibrated examiners using the ICDAS-II visual examination system, bitewing radiographs, and micro-CT. The teeth included in the study were selected randomly from solution before all measurements. For micro-CT, the device was set to 50 kV, 800 µA, pixel size 15 µm (at 1024 × 1024 resolution), and 1° rotation step. NRecon software (SkyScan) was used to obtain reconstructed images. For each diagnostic method, results were compared with histology results using the McNemar test. Receiver operator characteristic (ROC) analysis was also performed for each method (Z-test; p < 0.05). Besides showing a high correlation with histology results, micro-CT yielded the greatest values at the D3 threshold; moreover, accuracy and area under the ROC curve (AUC) values were greatest at the D1threshold. Our results indicate that micro-CT performs as well as or better than histological examination for the purpose of comparing methods for caries detection.

Entities:  

Mesh:

Year:  2015        PMID: 26892360     DOI: 10.1590/1807-3107BOR-2015.vol29.0132

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  9 in total

1.  In vitro validation of near-infrared transillumination at 780 nm for the detection of caries on proximal surfaces.

Authors:  Alexander Lederer; Karl-Heinz Kunzelmann; Katrin Heck; Reinhard Hickel; Friederike Litzenburger
Journal:  Clin Oral Investig       Date:  2019-01-28       Impact factor: 3.573

2.  Diagnostic validity of the use of ICDAS II and DIAGNOdent pen verified by micro-computed tomography for the detection of occlusal caries lesions-an in vitro evaluation.

Authors:  Elzbieta Luczaj-Cepowicz; Grazyna Marczuk-Kolada; Marta Obidzinska; Jarosław Sidun
Journal:  Lasers Med Sci       Date:  2019-06-14       Impact factor: 3.161

3.  Validity of micro-CT for in vitro caries detection: a systematic review and meta-analysis.

Authors:  Luciana Butini Oliveira; Carla Massignan; Anne Caroline Oenning; Karla Rovaris; Michele Bolan; André Luís Porporatti; Graziela De Luca Canto
Journal:  Dentomaxillofac Radiol       Date:  2019-11-20       Impact factor: 2.419

4.  In vitro comparison of two types of digital X-ray sensors for proximal caries detection validated by micro-computed tomography.

Authors:  Katrin Heck; Friederike Litzenburger; Verena Ullmann; Lea Hoffmann; Karl-Heinz Kunzelmann
Journal:  Dentomaxillofac Radiol       Date:  2020-08-27       Impact factor: 2.419

5.  Comparison of micro-CT imaging and histology for approximal caries detection.

Authors:  C Boca; B Truyen; L Henin; A G Schulte; V Stachniss; N De Clerck; J Cornelis; P Bottenberg
Journal:  Sci Rep       Date:  2017-07-27       Impact factor: 4.379

6.  Feasibility of micro-computed tomography to detect and classify proximal caries lesions in vitro.

Authors:  Karla Rovaris; Liana Matos Ferreira; Thiago Oliveira Sousa; Leonardo Vieira Peroni; Deborah Queiroz Freitas; Ann Wenzel; Francisco Haiter-Neto
Journal:  Dent Res J (Isfahan)       Date:  2018 Mar-Apr

Review 7.  Micro-computed tomography in preventive and restorative dental research: A review.

Authors:  Mehrsima Ghavami-Lahiji; Reza Tayefeh Davalloo; Gelareh Tajziehchi; Paria Shams
Journal:  Imaging Sci Dent       Date:  2021-10-15

8.  Near-infrared reflection at 780 nm for detection of early proximal caries in posterior permanent teeth in vitro.

Authors:  Katrin Heck; Friederike Litzenburger; Thomas Geitl; Karl-Heinz Kunzelmann
Journal:  Dentomaxillofac Radiol       Date:  2021-05-06       Impact factor: 3.525

9.  New Caries Diagnostic Tools in Intraoral Scanners: A Comparative In Vitro Study to Established Methods in Permanent and Primary Teeth.

Authors:  Maximiliane Amelie Schlenz; Berenike Schupp; Alexander Schmidt; Bernd Wöstmann; Ingo Baresel; Norbert Krämer; Nelly Schulz-Weidner
Journal:  Sensors (Basel)       Date:  2022-03-10       Impact factor: 3.576

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.