Literature DB >> 26889929

Low-pressure barrier discharge ion source using air as a carrier gas and its application to the analysis of drugs and explosives.

Dilshadbek T Usmanov1,2, Zhan Yu1,3, Lee Chuin Chen4, Kenzo Hiraoka1, Shinichi Yamabe5.   

Abstract

In this work, a low-pressure air dielectric-barrier discharge (DBD) ion source using a capillary with the inner diameter of 0.115 and 12 mm long applicable to miniaturized mass spectrometers was developed. The analytes, trinitrotoluene (TNT), 1,3,5-trinitroperhydro-1,3,5-triazine (RDX), 1,3,5,7-tetranitroperhydro-1,3,5,7-tetrazocine (HMX), pentaerythritol tetranitrate (PETN), nitroglycerine (NG), hexamethylene triperoxide diamine (HMTD), caffeine, cocaine and morphine, introduced through the capillary, were ionized by a low-pressure air DBD. The ion source pressures were changed by using various sizes of the ion sampling orifice. The signal intensities of those analytes showed marked pressure dependence. TNT was detected with higher sensitivity at lower pressure but vice versa for other analytes. For all analytes, a marked signal enhancement was observed when a grounded cylindrical mesh electrode was installed in the DBD ion source. Among nine analytes, RDX, HMX, NG and PETN could be detected as cluster ions [analyte + NO3 ](-) even at low pressure and high temperature up to 180 °C. The detection indicates that these cluster ions are stable enough to survive under present experimental conditions. The unexpectedly high stabilities of these cluster ions were verified by density functional theory calculation.
Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  NO3−; atmospheric pressure chemical ionization; density functional theory calculations; dielectric-barrier discharge; explosive; on-site mass spectrometry

Mesh:

Substances:

Year:  2016        PMID: 26889929     DOI: 10.1002/jms.3732

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

Review 1.  Interpol review of controlled substances 2016-2019.

Authors:  Nicole S Jones; Jeffrey H Comparin
Journal:  Forensic Sci Int Synerg       Date:  2020-05-24

2.  Effects of Different Waveforms on the Performance of Active Capillary Dielectric Barrier Discharge Ionization Mass Spectrometry.

Authors:  Morphy C Dumlao; Dan Xiao; Daming Zhang; John Fletcher; William A Donald
Journal:  J Am Soc Mass Spectrom       Date:  2016-11-09       Impact factor: 3.109

3.  1,4-Benzoquinone as a Highly Efficient Dopant for Enhanced Ionization and Detection of Nitramine Explosives on a Single-Quadrupole Mass Spectrometer Fitted with a Helium-Plasma Ionization (HePI) Source.

Authors:  Julius Pavlov; David Douce; Steve Bajic; Athula B Attygalle
Journal:  J Am Soc Mass Spectrom       Date:  2019-10-31       Impact factor: 3.109

4.  Detection of Trace Explosives Using a Novel Sample Introduction and Ionization Method.

Authors:  Lingfeng Li; Tianyi Zhang; Wei Ge; Xingli He; Yunjing Zhang; Xiaozhi Wang; Peng Li
Journal:  Molecules       Date:  2022-07-17       Impact factor: 4.927

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.