| Literature DB >> 26883898 |
G Banasik1, O Segiet2, M Elwart2, M Szulik3, R Lenarczyk3, Z Kalarus3,4, T Kukulski3,4.
Abstract
BACKGROUND: Myocardial mechanical dyssynchrony induced by the presence of postinfarction scar and/or conduction abnormalities in patients with a left ventricular ejection fraction (LVEF) of < 35 % may be associated with a greater propensity toward inducing serious ventricular arrhythmia [(ventricular tachycardia (VT), ventricular fibrillation (VF)] and sudden cardiac death. The assessment of regional myocardial function using tissue Doppler echocardiography (TDE) allows for noninvasive analysis of regional mechanical dysfunction (LV mechanical dispersion). AIM: The aim of this study was to evaluate the TDE-based mechanical dispersion as a potential echocardiographic predictor of VT/VF.Entities:
Keywords: Dilated cardiomyopathy; Implantable cardioverter–defibrillator; Mechanical dyssynchrony; Sudden cardiac death; Ultrasound strain
Mesh:
Year: 2016 PMID: 26883898 PMCID: PMC5075015 DOI: 10.1007/s00059-015-4398-9
Source DB: PubMed Journal: Herz ISSN: 0340-9937 Impact factor: 1.443
Fig. 1Tissue Doppler echocardiography-based longitudinal strain curves derived from mid-inferior and mid-anterior segments in two-chamber view
Clinical characteristics of study population
| Group 1 patients with VT/VF during follow-up ( | Group 2 patients without VT/VF during follow-up ( |
| |
|---|---|---|---|
| Age (years) | 66.38 ± 8.81 | 68.50 ± 12.23 | NS |
| Sex (M = 1) | 24 (82 %) | 12 (67 %) | NS |
| BMI | 28.02 ± 5.54 | 27.54 ± 4.26 | NS |
| Ischemic etiology, | 15 (52 %) | 14 (78 %) | NS |
| Arterial hypertension, | 11 (38 %) | 12 (67 %) | NS |
| Cardiomyopathy, | 23 (79 %) | 8 (44 %) | 0.014 |
| DM total, | 11 (38 %) | 5 (28 %) | NS |
| Hyperlipidemia, | 7 (24 %) | 5 (28 %) | NS |
| Atrial fibrillation, | 9 (31 %) | 5 (28 %) | NS |
| QRS duration (ms) | 161.59 ± 32.34 | 179.94 ± 35.42 | NS |
| Mean blood pressure (mmHg) | 96.94 ± 10.10 | 100.97 ± 12.26 | NS |
| K (mmol/l) | 4.51 ± 0.49 | 4.44 ± 0.40 | NS |
| Pre-implantation PCI, | 10 (34 %) | 6 (33 %) | NS |
| Beta-blocker, | 25 (86 %) | 16 (89 %) | NS |
| ACEI/ARB, | 24 (83 %) | 15 (83 %) | NS |
ACEI/ARB angiotensin-converting enzyme inhibitors/angiotensin receptor blockers, BMI body mass index, DM diabetes mellitus, K potassium, NS not significant, PCI percutaneous coronary intervention, VF ventricular fibrillation, VT ventricular tachycardia
Echocardiographic measurements in all patients
| Group 1 patients with VT/VF during follow-up ( | GR 2 patients without VT/VF during follow-up ( |
| |
|---|---|---|---|
| Septal flash, | 14 (48 %) | 10 (56 %) | NS |
| EF (%) | 27.95 ± 10.68 | 28.87 ± 8.69 | NS |
| ESV (ml) | 191.71 ± 90.05 | 172.73 ± 73.52 | NS |
| EDV (ml) | 249.89 ± 108.69 | 215.46 ± 79.99 | NS |
| LVES dimension (mm) | 67.70 ± 12.43 | 67.67 ± 7.74 | NS |
| LVED dimension (mm) | 55.53 ± 16.38 | 54.67 ± 10.13 | NS |
| IVSD (mm) | 11.44 ± 5.12 | 10.33 ± 2.73 | NS |
| IVSS (mm) | 14.29 ± 5.70 | 14.17 ± 3.82 | NS |
| LVPWD (mm) | 10.50 ± 2.39 | 10.20 ± 1.48 | NS |
| LVPWS (mm) | 13.86 ± 4.04 | 13.40 ± 2.88 | NS |
| Mechanical dispersion (ms) | 99.14 ± 33.60 | 72.98 ± 19.70 | 0.002 |
EDV end-diastolic volume, EF ejection fraction, ESV end-systolic volume, IVSD interventricular septum diastolic diameter, IVSS interventricular septum systolic diameter, LVES left ventricular end systolic, LVED left ventricular end diastolic, LVPWD left ventricular posterior wall diastolicdiameter, LVPWS left ventricular posterior wall systolic diameter, NS not significant
Echocardiographic measurements in patients with heart failure of ischemic etiology
| ISCH 1 patients with VT/VF during follow-up ( | ISCH 2 patients without VT/VF during follow-up ( |
| |
|---|---|---|---|
| Septal flash, | 8 (53 %) | 9 (64 %) | NS |
| EF (%) | 29.33 ± 10.25 | 29.85 ± 8.91 | NS |
| ESV (ml) | 180.00 ± 79.33 | 173.00 ± 77.50 | NS |
| EDV (ml) | 252.67 ± 89.58 | 224.27 ± 81.74 | NS |
| LVES dimension (mm) | 66.50 ± 11.97 | 68.10 ± 7.20 | NS |
| LVED dimension (mm) | 56.22 ± 16.20 | 54.50 ± 9.20 | NS |
| IVSD (mm) | 11.50 ± 4.87 | 10.50 ± 1.29 | NS |
| IVSS (mm) | 13.00 ± 6.32 | 15.00 ± 1.15 | NS |
| LVPWS (mm) | 10.75 ± 3.01 | 10.67 ± 1.15 | NS |
| LVPWD (mm) | 13.67 ± 5.28 | 14.67 ± 2.08 | NS |
| Mechanical dispersion (ms) | 97.80 ± 30.06 | 74.15 ± 15.72 | 0.014 |
EDV end-diastolic volume, EF ejection fraction, ESV end-systolic volume, IVSD interventricular septum diastolic diameter, IVSS interventricular septum systolic diameter, LVES left ventricular end systolic, LVED left ventricular end diastolic, LVPWD left ventricular posterior wall diastolic diameter, LVPWS left ventricular posterior wall systolic diameter, NS not significant
Fig. 2ROC curve for the ability of mechanical dispersion to identify arrhythmic events during a 4-year follow-up in ischemic patients